108922-2024 ZEXEL 9 400 611 136 BOSCH INJECTION-PUMP ASSEMBLY 9400611136 1089222024 me162277


108922-2024 INJECTION-PUMP ASSEMBLY
Rating:
8
Buy INJECTION-PUMP ASSEMBLY 108922-2024 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 611 136 9400611136
ZEXEL 108922-2024 1089222024
MITSUBISHI ME162277 me162277

Service parts 108922-2024 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 108092-0032
3. GOVERNOR 105952-1263
4. SUPPLY PUMP 105237-4810
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105664-0990
7. COUPLING PLATE
10. NOZZLE AND HOLDER ASSY 105110-7200
11. Nozzle and Holder ME161177
12. Open Pre:MPa(Kqf/cm2) 15.7{160}/24.5{250}
13. NOZZLE-HOLDER 105041-4070
14. NOZZLE 105015-9690
15. NOZZLE SET

Include in #1:

108922-2024 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 611 136 9400611136
ZEXEL 108922-2024 1089222024
MITSUBISHI ME162277 me162277


Zexel num
Bosch num
Firm num
Name
108922-2024 
108922-2060 
9 400 611 136 
ME162277  MITSUBISHI
INJECTION-PUMP ASSEMBLY
10M20 K 14CR INJECTION PUMP ASSY TICS HD-TI10F TICS

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8250
Bosch type code   1 688 901 101
Nozzle   105780-0120
Bosch type code   1 688 901 990
Nozzle holder   105780-2190
Opening pressure MPa   20.7
Opening pressure kgf/cm2   211
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   131425-0220
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
RED3 control unit part number   407910-2 470
RED3 rack sensor specifications mm   15
PS/ACT control unit part no.   407980-2 24*
Digi switch no.   52
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-2-7-8- 5-6-3-4- 9-10
Pre-stroke mm   8.5 8.47 8.53
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cyl.1-2
deg.   45 44.75 45.25
Difference between angles 2
Cal 1-7
deg.   72 71.75 72.25
Difference between angles 3
Cal 1-8
deg.   117 116.75 117.25
Difference between angles 4
Cal 1-5
deg.   144 143.75 144.25
Difference between angles 5
Cal 1-6
deg.   189 188.75 189.25
Difference between angles 6
Cal 1-3
deg.   216 215.75 216.25
Difference between angles 7
Cal 1-4
deg.   261 260.75 261.25
Difference between angles 8
Cal 1-9
deg.   288 287.75 288.25
Difference between angles 9
Cal 1-10
deg.   333 332.75 333.25
Injection quantity adjustment
Rack position   (11.2)
Vist V   1.75 1.75 1.75
Pump speed r/min   650 650 650
Average injection quantity mm3/st.   134 133 135
Max. variation between cylinders %   0 -3 3
Basic   *
PS407980-224* V   2.45+-0. 01
PS407980-224* mm   6.1+-0.0 5
Injection quantity adjustment_02
Rack position   (6.8)
Vist V   2.6 2.5 2.7
Pump speed r/min   330 330 330
Average injection quantity mm3/st.   19 17 21
Max. variation between cylinders %   0 -15 15
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   8.4+-0.0 3
Remarks
Refer to items regarding the pre-stroke actuator
 
0000001201
Pre-stroke mm   8.5 8.47 8.53
Remarks
When the timing sleeve is pushed up
 
_02
Connector angle deg.   8.5 8 9
Remarks
When the eccentric pin is tightened
 
_03
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   6.1 6.05 6.15
Output voltage V   2.45 2.44 2.46
Adjustment   *
_04
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   8.5 8.47 8.53
Output voltage V   1.2 1 1.4
Confirmation   *
Remarks
Output voltage V1
 
_05
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   5.5
Output voltage V   3 2.98 3
Confirmation   *
_06
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Output voltage V   3.05 3.05
Confirmation of operating range   *

Test data Ex:

Speed control lever angle

Test data 108922-2024
N:Pump normal S:Stop the pump. (1)Rack position = aa (2)Rack position bb
----------
aa=16mm bb=1mm
----------
a=27deg+-5deg b=29deg+-5deg

0000000901

Test data 108922-2024
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)At the No 1 cylinder's beginning of injection position, stamp an aligning mark on the damper to align with the pointer's groove. (4)Damper (5)Pointer (6)B.T.D.C.: aa (7)Pre-stroke: bb
----------
aa=6deg bb=8.5+-0.03mm
----------
a=(45deg) b=(44deg)

0000001501

Test data 108922-2024
A:Sealing position B:Pre-stroke actuator 1. When installing the pre-stroke actuator on the pump, first tighten the installation bolts loosely, then move the actuator fully counterclockwise (viewed from the drive side). Temporary tightening torque: 1 - 1.5 N.m (0.1 - 0.15 kgf.m) 2. Move the actuator in the clockwise direction when viewed from the drive side, and adjust so that it becomes the adjustment point of the adjustment value. Then tighten it. Tightening torque: 7^9 N.m (0.7^0.9 kgf.m) 3. After prestroke actuator installation adjustment, simultaneously stamp both the actuator side and housing side.
----------

----------

0000001701

Test data 108922-2024
(Rs) rack sensor specifications (C/U) control unit part number (V) Rack sensor output voltage (R) Rack position (mm) 1. Confirming governor output characteristics (rack 15 mm, span 6 mm) (1)When the output voltages of the rack sensor are V1 and V2, check that the rack positions R1 and R2 in the table above are satisfied.
----------

----------

0000001901 RACK SENSOR

Test data 108922-2024
(VR) measurement voltage (I) Part number of the control unit (G) Apply red paint. (H): End surface of the pump 1. Rack sensor adjustment (154610-0620) (1)At governor side rack sensor output voltage V1, adjust the bobbin (A) so that the drive side rack sensor output voltage is VR+-0.01. (2)Apply G at two places. Connecting part between the joint (B) and the nut (F) Connecting part between the joint (B) and the end surface of the pump (H)
----------
V1=1V
----------




Have questions with 108922-2024?





Group cross 108922-2024 ZEXEL

9 400 619 478 
 
INJECTION-PUMP ASSEMBLY
9 400 619 479 
 
INJECTION-PUMP ASSEMBLY
9 400 619 480 
 
INJECTION-PUMP ASSEMBLY
9 400 619 481 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

108922-2024  

108922-2060 
9 400 611 136 
ME162277 
INJECTION-PUMP ASSEMBLY
10M20
Back to top