108822-3322 ZEXEL 9 400 612 292 BOSCH INJECTION-PUMP ASSEMBLY 9400612292 1088223322 220402102a


108822-3322 INJECTION-PUMP ASSEMBLY
Rating:
50
Buy INJECTION-PUMP ASSEMBLY 108822-3322 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 612 292 9400612292
ZEXEL 108822-3322 1088223322
HINO 220402102A 220402102a

Service parts 108822-3322 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 108082-3830
3. GOVERNOR 105923-4782
4. SUPPLY PUMP 105237-0150
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105664-2180
7. COUPLING PLATE
10. NOZZLE AND HOLDER ASSY 105101-8240
11. Nozzle and Holder 23600-3040A
12. Open Pre:MPa(Kqf/cm2) 14.7{150}/21.6{220}
13. NOZZLE-HOLDER 105030-3730
14. NOZZLE
15. NOZZLE SET 105019-0880

Include in #1:

108822-3322 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 612 292 9400612292
ZEXEL 108822-3322 1088223322
HINO 220402102A 220402102a


Zexel num
Bosch num
Firm num
Name
108822-3322 
108822-3323 
9 400 612 292 
220402102A  HINO
INJECTION-PUMP ASSEMBLY
F21C-F * K 14CK TICS HD-TI8M TICS

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8250
Bosch type code   1 688 901 101
Nozzle   105780-0120
Bosch type code   1 688 901 990
Nozzle holder   105780-2190
Opening pressure MPa   20.7
Opening pressure kgf/cm2   211
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   134424-4120
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
PS/ACT control unit part no.   407980-2 24*
Digi switch no.   41
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-8-6-2- 7-5-4-3
Pre-stroke mm   7.2 7.17 7.23
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-8
deg.   45 44.75 45.25
Difference between angles 2
Cal 1-6
deg.   90 89.75 90.25
Difference between angles 3
Cyl.1-2
deg.   135 134.75 135.25
Difference between angles 4
Cal 1-7
deg.   180 179.75 180.25
Difference between angles 5
Cal 1-5
deg.   225 224.75 225.25
Difference between angles 6
Cal 1-4
deg.   270 269.75 270.25
Difference between angles 7
Cal 1-3
deg.   315 314.75 315.25
Injection quantity adjustment
Adjusting point   -
Rack position   11.8
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   107 104 110
Max. variation between cylinders %   0 -3 3
Basic   *
Fixing the rack   *
PS407980-224* V   2.2+-0.0 1
PS407980-224* mm   4.8+-0.0 5
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   Z
Rack position   7.7+-0.5
Pump speed r/min   435 435 435
Average injection quantity mm3/st.   13.3 12.3 14.3
Max. variation between cylinders %   0 -10 10
Fixing the rack   *
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   7.1+-0.0 3
Standard for adjustment of the maximum variation between cylinders   *
Remarks
Refer to items regarding the pre-stroke actuator
 
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.8)
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   107 105 109
Basic   *
Fixing the lever   *
PS407980-224* V   2.2+-0.0 1
PS407980-224* mm   4.8+-0.0 5
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+1
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   105.5 99.5 111.5
Fixing the lever   *
PS407980-224* V   2.2+-0.0 1
PS407980-224* mm   4.8+-0.0 5
0000001601
Pre-stroke mm   7.2 7.17 7.23
Remarks
When the timing sleeve is pushed up
 
_02
Connector angle deg.   11.5 11 12
Remarks
When the eccentric pin is tightened
 
_03
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   3.2 3.15 3.25
Output voltage V   2.95 2.94 2.96
Adjustment   *
_04
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   7.2 7.17 7.23
Output voltage V   1.2 1 1.4
Confirmation   *
Remarks
Output voltage V1
 
_05
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Output voltage V   3.05 3.05
Confirmation of operating range   *

Test data Ex:

Governor adjustment

Test data 108822-3322
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)Set the stop lever before governor adjustment. [When setting the stop lever after governor adjustment, confirm that R = R1 + 1 (point B) can be obtained at the full setting.] (4)Stop lever's normal position setting: RA (5)Damper spring setting: DL
----------
T1=AG89 RA=(17)mm DL=7.4-0.2mm
----------

Speed control lever angle

Test data 108822-3322
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt setting
----------
aa=94mm
----------
a=15.5deg+-5deg b=39deg+-3deg

Stop lever angle

Test data 108822-3322
N:Pump normal S:Stop the pump. (1)Pump speed aa, rack position bb (2)Stopper bolt setting (3)Speed = aa, rack position = CC (4)Stopper bolt setting (5)Use the hole above R = dd
----------
aa=0r/min bb=(17)mm cc=0.5+-0.3mm dd=35mm
----------
a=35deg+-5deg b=23deg+-5deg

0000001301

Test data 108822-3322
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)At the No 1 cylinder's beginning of injection position, stamp an aligning mark on the damper to align with the pointer's groove. (4)Damper (5)Pointer (6)B.T.D.C.:- (7)Pre-stroke: aa
----------
aa=7.2+-0.03mm
----------
a=(80deg)

0000001901

Test data 108822-3322
A:Sealing position B:Pre-stroke actuator 1. When installing the pre-stroke actuator on the pump, first tighten the installation bolts loosely, then move the actuator fully counterclockwise (viewed from the drive side). Temporary tightening torque: 1 - 1.5 N.m (0.1 - 0.15 kgf.m) 2. Move the actuator in the clockwise direction when viewed from the drive side, and adjust so that it becomes the adjustment point of the adjustment value. Then tighten it. Tightening torque: 7^9 N.m (0.7^0.9 kgf.m) 3. After prestroke actuator installation adjustment, simultaneously stamp both the actuator side and housing side.
----------

----------

0000002201 RACK SENSOR

Test data 108822-3322
(VR) measurement voltage (I) Part number of the control unit (G) Apply red paint. (H): End surface of the pump 1. Rack sensor adjustment (-0620) (1)Fix the speed control lever at the full position (2)Set the speed to N1 r/min. (If the boost compensator is provided, apply boost pressure.) (3)Adjust the bobbin (A) so that the rack sensor's output voltage is VR+-0.01. (4)At that time, rack position must be Ra. (5)Apply G at two places. Connecting part between the joint (B) and the nut (F) Connecting part between the joint (B) and the end surface of the pump (H)
----------
N1=1100r/min Ra=R1(11.8)+1mm
----------




Have questions with 108822-3322?





Group cross 108822-3322 ZEXEL

Hino 

 
220401730A 
INJECTION-PUMP ASSEMBLY
F21C-E
 
220401731A 
INJECTION-PUMP ASSEMBLY
F21C-E
 
220401732A 
INJECTION-PUMP ASSEMBLY
F21C-E
F 01G 09U 0HB 
 
INJECTION-PUMP ASSEMBLY
9 400 611 927 
 
INJECTION-PUMP ASSEMBLY

Hino 

9 400 612 061 
220401732C 
INJECTION-PUMP ASSEMBLY
F21C-E
9 400 612 191 
220401732D 
INJECTION-PUMP ASSEMBLY
F21C-E
F 01G 09U 0HC 
220401733A 
INJECTION-PUMP ASSEMBLY
F21C-E
9 400 612 327 
220401734A 
INJECTION-PUMP ASSEMBLY
F21C-E
 
 
INJECTION-PUMP ASSEMBLY
9 400 611 974 
 
INJECTION-PUMP ASSEMBLY

Hino 

9 400 612 062 
220402030B 
INJECTION-PUMP ASSEMBLY
F21C-C
9 400 612 151 
220402031A 
INJECTION-PUMP ASSEMBLY
F21C-C
F 01G 09U 0HD 
220402032A 
INJECTION-PUMP ASSEMBLY
F21C-C
9 400 612 328 
220402033A 
INJECTION-PUMP ASSEMBLY
F21C-C
9 400 612 328 
S220402033 
INJECTION-PUMP ASSEMBLY
F21C-C
 
220402100A 
INJECTION-PUMP ASSEMBLY
F21C-F
 
220402101A 
INJECTION-PUMP ASSEMBLY
F21C-F
108822-3322  

108822-3323 
9 400 612 292 
220402102A 
INJECTION-PUMP ASSEMBLY
F21C-F
9 400 619 359 
220402103A 
INJECTION-PUMP ASSEMBLY
F21C-F
Back to top