108822-2800 ZEXEL 9 400 619 329 BOSCH INJECTION-PUMP ASSEMBLY 9400619329 1088222800 me095197


108822-2800 INJECTION-PUMP ASSEMBLY
Rating:
40
Buy INJECTION-PUMP ASSEMBLY 108822-2800 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 619 329 9400619329
ZEXEL 108822-2800 1088222800
MITSUBISHI ME095197 me095197

Service parts 108822-2800 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 108082-3301
3. GOVERNOR 105923-3780
4. SUPPLY PUMP 105237-4870
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105664-0990
7. COUPLING PLATE
10. NOZZLE AND HOLDER ASSY 105110-7381
11. Nozzle and Holder ME093732
12. Open Pre:MPa(Kqf/cm2) 17.7{180}/21.6{220}
13. NOZZLE-HOLDER 105041-4120
14. NOZZLE
15. NOZZLE SET 105019-0350

Include in #1:

108822-2800 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 619 329 9400619329
ZEXEL 108822-2800 1088222800
MITSUBISHI ME095197 me095197


Zexel num
Bosch num
Firm num
Name
108822-2800 
108822-2900 
9 400 619 329 
ME095197  MITSUBISHI
INJECTION-PUMP ASSEMBLY
8DC11 K 14CK INJECTION PUMP ASSY TICS HD-TI8M TICS

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8250
Bosch type code   1 688 901 101
Nozzle   105780-0120
Bosch type code   1 688 901 990
Nozzle holder   105780-2190
Opening pressure MPa   20.7
Opening pressure kgf/cm2   211
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   131425-0220
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
PS/ACT control unit part no.   407980-2 24*
Digi switch no.   42
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-2-7-3- 4-5-6-8
Pre-stroke mm   8.5 8.47 8.53
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cyl.1-2
deg.   45 44.75 45.25
Difference between angles 2
Cal 1-7
deg.   90 89.75 90.25
Difference between angles 3
Cal 1-3
deg.   135 134.75 135.25
Difference between angles 4
Cal 1-4
deg.   180 179.75 180.25
Difference between angles 5
Cal 1-5
deg.   225 224.75 225.25
Difference between angles 6
Cal 1-6
deg.   270 269.75 270.25
Difference between angles 7
Cal 1-8
deg.   315 314.75 315.25
Injection quantity adjustment
Adjusting point   -
Rack position   13.3
Pump speed r/min   650 650 650
Average injection quantity mm3/st.   136.5 134.9 138.1
Max. variation between cylinders %   0 -3 3
Basic   *
Fixing the rack   *
PS407980-224* V   2.45+-0. 01
PS407980-224* mm   6.1+-0.0 5
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   Z
Rack position   8.7+-0.5
Pump speed r/min   345 345 345
Average injection quantity mm3/st.   23.5 20.9 26.1
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   8.4+-0.0 3
Standard for adjustment of the maximum variation between cylinders   *
Remarks
Refer to items regarding the pre-stroke actuator
 
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(13.3)
Pump speed r/min   650 650 650
Average injection quantity mm3/st.   136.5 135.5 137.5
Basic   *
Fixing the lever   *
PS407980-224* V   2.45+-0. 01
PS407980-224* mm   6.1+-0.0 5
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+1.35
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   135.5 131.5 139.5
Fixing the lever   *
PS407980-224* V   2.45+-0. 01
PS407980-224* mm   6.1+-0.0 5
Injection quantity adjustment_05
Adjusting point   C
Rack position   (R1-0.7)
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   132.5 128.5 136.5
Fixing the lever   *
PS407980-224* V   2.45+-0. 01
PS407980-224* mm   6.1+-0.0 5
0000001601
Pre-stroke mm   8.5 8.47 8.53
Remarks
When the timing sleeve is pushed up
 
_02
Connector angle deg.   8.5 8 9
Remarks
When the eccentric pin is tightened
 
_03
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   6.1 6.05 6.15
Output voltage V   2.45 2.44 2.46
Adjustment   *
_04
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   8.5 8.47 8.53
Output voltage V   1.2 1 1.4
Confirmation   *
Remarks
Output voltage V1
 
_05
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   5.5
Output voltage V   3 2.98 3
Confirmation   *
_06
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Output voltage V   3.05 3.05
Confirmation of operating range   *

Test data Ex:

Governor adjustment

Test data 108822-2800
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)Air cylinder ON (4)Air cylinder OFF (5)Damper spring setting
----------
T1=AF40
----------

Speed control lever angle

Test data 108822-2800
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H' (3)When air cylinder ON. (4)When air cylinder OFF. (5)Viewed from feed pump side.
----------
aa=37.5mm
----------
a=(6.5deg) b=31.5deg+-3deg c=34deg+-5deg

Stop lever angle

Test data 108822-2800
N:Pump normal S:Stop the pump. (1)Use the hole at R = aa (2)Set the stopper bolt so that speed = bb and rack position = cc. (Confirm non-injection.) (3)Normal engine position (Rack position corresponding to dd)
----------
aa=54mm bb=1100r/min cc=3.5+-0.3mm dd=18mm
----------
a=41deg+-5deg b=5.5deg+-5deg c=(31deg)

0000001301

Test data 108822-2800
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)At the No 1 cylinder's beginning of injection position, stamp an aligning mark on the damper to align with the pointer's groove. (4)Damper (5)Pointer (6)B.T.D.C.: aa (7)Pre-stroke: bb
----------
aa=4deg bb=8.5+-0.03mm
----------
a=(45deg) b=(44deg)

0000001901

Test data 108822-2800
A:Sealing position B:Pre-stroke actuator 1. When installing the pre-stroke actuator on the pump, first tighten the installation bolts loosely, then move the actuator fully counterclockwise (viewed from the drive side). Temporary tightening torque: 1 - 1.5 N.m (0.1 - 0.15 kgf.m) 2. Move the actuator in the clockwise direction when viewed from the drive side, and adjust so that it becomes the adjustment point of the adjustment value. Then tighten it. Tightening torque: 7^9 N.m (0.7^0.9 kgf.m) 3. After prestroke actuator installation adjustment, simultaneously stamp both the actuator side and housing side.
----------

----------

0000002201 RACK SENSOR

Test data 108822-2800
(VR) measurement voltage (I) Part number of the control unit (G) Apply red paint. (H): End surface of the pump 1. Rack sensor adjustment (-0620) (1)Fix the speed control lever at the full position (2)Set the speed to N1 r/min. (If the boost compensator is provided, apply boost pressure.) (3)Adjust the bobbin (A) so that the rack sensor's output voltage is VR+-0.01. (4)At that time, rack position must be Ra. (5)Apply G at two places. Connecting part between the joint (B) and the nut (F) Connecting part between the joint (B) and the end surface of the pump (H)
----------
N1=1100r/min Ra=R1(13.3)+1.35mm
----------

0000002301 AIR CYLINDER

Test data 108822-2800
<A> stopper bolt <B> stopper bolt <C> stopper bolt (a) lever (b) air cylinder (c) speed lever (d) Nut (e) nut (f) lever (g) nut 1. Stopper bolt <A> adjustment method (1)When air cylinder pressure is P1, set the gap between the lever (a) and the air cylinder (b) to L1. (2)Confirm that the speed lever (c) operates between idling and full speed. (3)Fix stopper bolt <A> using nut (d). 2. Stopper bolt <B> adjustment method. (1)At air cylinder pressure P2, pump speed N1 and rack position is R1, adjust stopper bolt (B) so that the speed lever (c) is in the stop position. (2)Turn the stopper bolt (c) so that the clearance between lever (a) and lever (f) is L2, then fix using nut (g). (3)Move the lever (a) several times and fix stopper bolt <B> using the nut (e). (4)Tightening torque T1 for nuts (d), (e) and (g)
----------
L1=0.2++mm L2=0~1.5mm P1=0kPa(0kgf/cm2) P2=686+98kpa(7+1kgf/cm2) N1=530r/min R1=8.2+-0.1mm T1=4.9~6.86N-m(0.5~0.7kgf-m)
----------




Have questions with 108822-2800?





Group cross 108822-2800 ZEXEL

Mitsubishi 

108822-2800  

108822-2900 
9 400 619 329 
ME095197 
INJECTION-PUMP ASSEMBLY
8DC11
9 400 613 087 
ME095198 
INJECTION-PUMP ASSEMBLY
8DC11
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 619 330 
ME095199 
INJECTION-PUMP ASSEMBLY
8DC11
9 400 611 487 
ME095209 
INJECTION-PUMP ASSEMBLY
8DC11
9 400 619 331 
ME095131 
INJECTION-PUMP ASSEMBLY
8DC11
F 019 Z20 376 
ME354497 
INJECTION-PUMP ASSEMBLY
8DC11
9 400 619 332 
ME095132 
INJECTION-PUMP ASSEMBLY
8DC11
F 019 Z20 377 
ME354498 
INJECTION-PUMP ASSEMBLY
8DC11
F 019 Z20 509 
ME163705 
INJECTION-PUMP ASSEMBLY
8M21
9 400 619 333 
ME095227 
INJECTION-PUMP ASSEMBLY
8DC11
9 400 619 334 
ME095228 
INJECTION-PUMP ASSEMBLY
8DC11
9 400 611 673 
ME095229 
INJECTION-PUMP ASSEMBLY
8DC11
Back to top