108622-3770 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1086223770


108622-3770 INJECTION-PUMP ASSEMBLY
Rating:
39
Buy INJECTION-PUMP ASSEMBLY 108622-3770 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 108622-3770 1086223770

Service parts 108622-3770 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 108062-3660
3. GOVERNOR 105952-2340
4. SUPPLY PUMP 105237-4690
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105664-0740
7. COUPLING PLATE 156638-7720
9. _
10. NOZZLE AND HOLDER ASSY 105101-8212
11. Nozzle and Holder 23600-3001A
12. Open Pre:MPa(Kqf/cm2) 16.7{170}/27.5{280}
13. NOZZLE-HOLDER 105030-3711
14. NOZZLE
15. NOZZLE SET 105019-0850

Include in #1:

108622-3770 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 108622-3770 1086223770


Zexel num
Bosch num
Firm num
Name
108622-3770 
 
   
INJECTION-PUMP ASSEMBLY

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8250
Bosch type code   1 688 901 101
Nozzle   105780-0120
Bosch type code   1 688 901 990
Nozzle holder   105780-2190
Opening pressure MPa   20.7
Opening pressure kgf/cm2   211
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   134424-1420
Overflow valve opening pressure kPa   162 147 177
Overflow valve opening pressure kgf/cm2   1.65 1.5 1.8
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
RED3 control unit part number   407910-2 470
RED3 rack sensor specifications mm   15
PS/ACT control unit part no.   407980-2 24*
Digi switch no.   33
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-4-2-6- 3-5
Pre-stroke mm   6.4 6.37 6.43
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-4
deg.   60 59.75 60.25
Difference between angles 2
Cyl.1-2
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cal 1-3
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-5
deg.   300 299.75 300.25
Injection quantity adjustment
Rack position   (13.4)
Vist V   1.32 1.32 1.32
Pump speed r/min   550 550 550
Average injection quantity mm3/st.   184 182 186
Max. variation between cylinders %   0 -2 2
Basic   *
PS407980-224* V   2.2+-0.0 1
PS407980-224* mm   4+-0.05
Injection quantity adjustment_02
Rack position   (6.9)
Vist V   2.6 2.5 2.7
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   17 14 20
Max. variation between cylinders %   0 -15 15
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   6.3+-0.0 3
Remarks
Refer to items regarding the pre-stroke actuator
 
0000001201
Pre-stroke mm   6.4 6.37 6.43
Remarks
When the timing sleeve is pushed up
 
_02
Connector angle deg.   11.5 11 12
Remarks
When the eccentric pin is tightened
 
_03
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   2.4 2.35 2.45
Output voltage V   2.95 2.94 2.96
Adjustment   *
_04
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   6.4 6.37 6.43
Output voltage V   1.2 1 1.4
Confirmation   *
Remarks
Output voltage V1
 
_05
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Output voltage V   3.05 3.05
Confirmation of operating range   *

Test data Ex:

Speed control lever angle

Test data 108622-3770
N:Pump normal S:Stop the pump. (1)Rack position = aa (2)Rack position bb
----------
aa=1mm bb=13.6+-0.2mm
----------
a=27.5deg+-5deg b=24deg+-5deg

0000000901

Test data 108622-3770
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)Pre-stroke: aa (4)-
----------
aa=6.4+-0.03mm
----------
a=(45deg)

0000001501

Test data 108622-3770
A:Sealing position B:Pre-stroke actuator 1. When installing the pre-stroke actuator on the pump, first tighten the installation bolts loosely, then move the actuator fully counterclockwise (viewed from the drive side). Temporary tightening torque: 1 - 1.5 N.m (0.1 - 0.15 kgf.m) 2. Move the actuator in the clockwise direction when viewed from the drive side, and adjust so that it becomes the adjustment point of the adjustment value. Then tighten it. Tightening torque: 7^9 N.m (0.7^0.9 kgf.m) 3. After prestroke actuator installation adjustment, simultaneously stamp both the actuator side and housing side.
----------

----------

0000001701

Test data 108622-3770
(Rs) rack sensor specifications (C/U) control unit part number (V) Rack sensor output voltage (R) Rack position (mm) 1. Confirming governor output characteristics (rack 15 mm, span 6 mm) (1)When the output voltages of the rack sensor are V1 and V2, check that the rack positions R1 and R2 in the table above are satisfied.
----------

----------




Have questions with 108622-3770?





Group cross 108622-3770 ZEXEL

108622-3770  
 
 
INJECTION-PUMP ASSEMBLY

Hino 

 
220401610A 
INJECTION-PUMP ASSEMBLY
P11C-TD
 
220401611A 
INJECTION-PUMP ASSEMBLY
P11C-TD
9 400 611 733 
220401612A 
INJECTION-PUMP ASSEMBLY
P11C-TD
9 400 611 406 
 
INJECTION-PUMP ASSEMBLY

Hino 

9 400 611 773 
220402091A 
INJECTION-PUMP ASSEMBLY
P11C-TD
9 400 612 244 
220402092A 
INJECTION-PUMP ASSEMBLY
P11C-TD
F 01G 09U 0FW 
220402093A 
INJECTION-PUMP ASSEMBLY
P11C-TD
9 400 619 200 
220402094A 
INJECTION-PUMP ASSEMBLY
P11C-TD
Back to top