108622-3433 ZEXEL F 01G 09U 0FB BOSCH INJECTION-PUMP ASSEMBLY f01g09u0fb 1086223433 220008863a


108622-3433 INJECTION-PUMP ASSEMBLY
Rating:
46
Buy INJECTION-PUMP ASSEMBLY 108622-3433 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH F 01G 09U 0FB f01g09u0fb
ZEXEL 108622-3433 1086223433
HINO 220008863A 220008863a

Service parts 108622-3433 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 108062-3251
3. GOVERNOR 105923-1332
4. SUPPLY PUMP 105237-4700
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105664-2200
7. COUPLING PLATE 156638-9920
9. _
10. NOZZLE AND HOLDER ASSY 105101-7913
11. Nozzle and Holder 23600-2800B
12. Open Pre:MPa(Kqf/cm2) 14.7{150}/21.6{220}
13. NOZZLE-HOLDER 105031-7363
14. NOZZLE
15. NOZZLE SET 105019-0570

Include in #1:

108622-3433 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH F 01G 09U 0FB f01g09u0fb
ZEXEL 108622-3433 1086223433
HINO 220008863A 220008863a


Zexel num
Bosch num
Firm num
Name
108622-3433 
108622-3434 
F 01G 09U 0FB 
220008863A  HINO
INJECTION-PUMP ASSEMBLY
K13U-B * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8250
Bosch type code   1 688 901 101
Nozzle   105780-0120
Bosch type code   1 688 901 990
Nozzle holder   105780-2190
Opening pressure MPa   20.7
Opening pressure kgf/cm2   211
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   134424-4120
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
PS/ACT control unit part no.   407980-2 24*
Digi switch no.   33
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-4-2-6- 3-5
Pre-stroke mm   7.2 7.17 7.23
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-4
deg.   60 59.75 60.25
Difference between angles 2
Cyl.1-2
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cal 1-3
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-5
deg.   300 299.75 300.25
Injection quantity adjustment
Adjusting point   -
Rack position   12.4
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   148 145 151
Max. variation between cylinders %   0 -2 2
Basic   *
Fixing the rack   *
PS407980-224* V   2.2+-0.0 1
PS407980-224* mm   4.8+-0.0 5
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   Z
Rack position   6.5+-0.5
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   15 12 18
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   7.1+-0.0 3
Standard for adjustment of the maximum variation between cylinders   *
Remarks
Refer to items regarding the pre-stroke actuator
 
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12.4)
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   148 146 150
Basic   *
Fixing the lever   *
PS407980-224* V   2.2+-0.0 1
PS407980-224* mm   4.8+-0.0 5
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.8
Pump speed r/min   1075 1075 1075
Average injection quantity mm3/st.   133.5 127.5 139.5
Fixing the lever   *
PS407980-224* V   2.2+-0.0 1
PS407980-224* mm   4.8+-0.0 5
0000001601
Pre-stroke mm   7.2 7.17 7.23
Remarks
When the timing sleeve is pushed up
 
_02
Connector angle deg.   8.5 8 9
Remarks
When the eccentric pin is tightened
 
_03
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   3.2 3.15 3.25
Output voltage V   2.95 2.94 2.96
Adjustment   *
_04
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   7.2 7.17 7.23
Output voltage V   1.2 1 1.4
Confirmation   *
Remarks
Output voltage V1
 
_05
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Output voltage V   3.05 3.05
Confirmation of operating range   *

Test data Ex:

Governor adjustment

Test data 108622-3433
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)Set stop lever before governor adjustment. [When setting stop lever after governor adjustment, confirm that point B (Ra) can be obtained at full setting.] (4)Stop lever's normal position setting: equivalent to RA (5)Damper spring setting
----------
T1=AD16 Ra=R1+0.8mm RA=16mm
----------

Speed control lever angle

Test data 108622-3433
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=36.5mm
----------
a=18deg+-5deg b=(40deg)+-3deg

Stop lever angle

Test data 108622-3433
N:Pump normal S:Stop the pump. (1)Set the stopper bolt at rack position = approximately aa. (2)At pump speed bb and rack position cc, set the stopper bolt. (Confirm non-injection at speed = dd.) (3)Use the hole above R = ee
----------
aa=16mm bb=0r/min cc=1.5+-0.3mm dd=1250r/min ee=35mm
----------
a=11deg+-5deg b=31deg+-5deg

0000001301

Test data 108622-3433
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)Pre-stroke: aa (4)-
----------
aa=7.2+-0.03mm
----------
a=(10deg)

0000001901

Test data 108622-3433
A:Sealing position B:Pre-stroke actuator 1. When installing the pre-stroke actuator on the pump, first tighten the installation bolts loosely, then move the actuator fully counterclockwise (viewed from the drive side). Temporary tightening torque: 1 - 1.5 N.m (0.1 - 0.15 kgf.m) 2. Move the actuator in the clockwise direction when viewed from the drive side, and adjust so that it becomes the adjustment point of the adjustment value. Then tighten it. Tightening torque: 7^9 N.m (0.7^0.9 kgf.m) 3. After prestroke actuator installation adjustment, simultaneously stamp both the actuator side and housing side.
----------

----------

0000002201 RACK SENSOR

Test data 108622-3433
(VR) measurement voltage (I) Part number of the control unit (G) Apply red paint. (H): End surface of the pump 1. Rack sensor adjustment (-0620) (1)Fix the speed control lever at the full position (2)Set the speed to N1 r/min. (If the boost compensator is provided, apply boost pressure.) (3)Adjust the bobbin (A) so that the rack sensor's output voltage is VR+-0.01. (4)At that time, rack position must be Ra. (5)Apply G at two places. Connecting part between the joint (B) and the nut (F) Connecting part between the joint (B) and the end surface of the pump (H)
----------
N1=1075r/min Ra=R1(12.4)+0.8mm
----------

0000002301 AIR CYLINDER

Test data 108622-3433
1. Air cylinder adjustment procedure (1)Set the speed lever at idle. (2)Temporarily set the clearance between the speed lever A and the set bolt B at L. (3)Set the speed at N. (4)Apply positive pressure P1 to the air cylinder. (5)Gradually push out the set bolt (B). (6)Tighten the nut (D) at the point where the rack position is Ra at speed N. (7)Apply positive pressure P1 several times. (8)Confirm that the lever returns to the idle position at positive pressure P2.
----------
L=(6)mm N=320r/min P1=392+98kPa(4+1kgf/cm2) P2=0kPa(0kgf/cm2) Ra=6.5+-0.1mm
----------




Have questions with 108622-3433?





Group cross 108622-3433 ZEXEL

Hino 

 
220008860A 
INJECTION-PUMP ASSEMBLY
K13U-B
 
220008861A 
INJECTION-PUMP ASSEMBLY
K13U-B
F 01G 09U 0FA 
220008862A 
INJECTION-PUMP ASSEMBLY
K13U-B
108622-3433  

108622-3434 
F 01G 09U 0FB 
220008863A 
INJECTION-PUMP ASSEMBLY
K13U-B
 
220008864A 
INJECTION-PUMP ASSEMBLY
K13U-B
F 01G 09U 0FC 
220008865A 
INJECTION-PUMP ASSEMBLY
K13U-B
 
220008865B 
INJECTION-PUMP ASSEMBLY
K13U-B
F 01G 09U 0FD 
220008866A 
INJECTION-PUMP ASSEMBLY
K13U-B
F 01G 09U 0FE 
220008867A 
INJECTION-PUMP ASSEMBLY
K13U-B
F 01G 09U 0FF 
 
INJECTION-PUMP ASSEMBLY
K13U-B
Back to top