108622-3190 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1086223190 220008240a


108622-3190 INJECTION-PUMP ASSEMBLY
Rating:
19
Buy INJECTION-PUMP ASSEMBLY 108622-3190 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 108622-3190 1086223190
HINO 220008240A 220008240a

Service parts 108622-3190 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 108062-0100
3. GOVERNOR 105489-4300
4. SUPPLY PUMP 105237-4410
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105664-0680
7. COUPLING PLATE 156638-0320
9. _
10. NOZZLE AND HOLDER ASSY 105101-7342
11. Nozzle and Holder 23600-2391B
12. Open Pre:MPa(Kqf/cm2) 16.7{170}/27.5{280}
13. NOZZLE-HOLDER 105030-3330
14. NOZZLE
15. NOZZLE SET 105019-0130

Include in #1:

108622-3190 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 108622-3190 1086223190
HINO 220008240A 220008240a


Zexel num
Bosch num
Firm num
Name
108622-3190 
108622-3191 
 
220008240A  HINO
INJECTION-PUMP ASSEMBLY
P-4 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   134424-1520
Overflow valve opening pressure kPa   162 147 177
Overflow valve opening pressure kgf/cm2   1.65 1.5 1.8
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
PS/ACT control unit part no.   407980-2 24*
Digi switch no.   21
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-4-2-6- 3-5
Pre-stroke mm   6.4 6.37 6.43
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-4
deg.   60 59.75 60.25
Difference between angles 2
Cyl.1-2
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cal 1-3
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-5
deg.   300 299.75 300.25
Injection quantity adjustment
Adjusting point   A
Rack position   10.8
Pump speed r/min   550 550 550
Average injection quantity mm3/st.   193.4 191.4 195.4
Max. variation between cylinders %   0 -2 2
Basic   *
Fixing the lever   *
Boost pressure kPa   64 64
Boost pressure mmHg   480 480
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   6.3+-0.0 3
Remarks
Refer to items regarding the pre-stroke actuator
 
Injection quantity adjustment_02
Adjusting point   B
Rack position   10.2
Pump speed r/min   1050 1050 1050
Average injection quantity mm3/st.   168.6 165.6 171.6
Fixing the lever   *
Boost pressure kPa   64 64
Boost pressure mmHg   480 480
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   6.3+-0.0 3
Injection quantity adjustment_03
Adjusting point   C
Rack position   9.05
Pump speed r/min   1150 1150 1150
Average injection quantity mm3/st.   138.2 135.2 141.2
Fixing the lever   *
Boost pressure kPa   64 64
Boost pressure mmHg   480 480
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   6.3+-0.0 3
Injection quantity adjustment_04
Adjusting point   D
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   220 215 225
Fixing the lever   *
Boost pressure kPa   64 64
Boost pressure mmHg   480 480
Rack limit   *
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   6.3+-0.0 3
Injection quantity adjustment_05
Adjusting point   E
Rack position   4+-0.5
Pump speed r/min   225 225 225
Average injection quantity mm3/st.   12.5 9.5 15.5
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   6.3+-0.0 3
Injection quantity adjustment_06
Adjusting point   G
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   129 129 169
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   6.3+-0.0 3
Injection quantity adjustment_07
Adjusting point   H
Rack position   10.8+-0. 5
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   192.1 186.1 198.1
Fixing the lever   *
Boost pressure kPa   64 64
Boost pressure mmHg   480 480
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   6.3+-0.0 3
Boost compensator adjustment
Pump speed r/min   550 550 550
Rack position   8.15
Boost pressure kPa   22 20 22
Boost pressure mmHg   165 150 165
Boost compensator adjustment_02
Pump speed r/min   550 550 550
Rack position   10.8
Boost pressure kPa   50.7 50.7 50.7
Boost pressure mmHg   380 380 380
0000001601
Pre-stroke mm   6.4 6.37 6.43
Remarks
When the timing sleeve is pushed up
 
_02
Connector angle deg.   5 4.5 5.5
Remarks
When the eccentric pin is tightened
 
_03
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   4 3.95 4.05
Output voltage V   2.62 2.61 2.63
Adjustment   *
_04
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   6.4 6.37 6.43
Output voltage V   1.2 1 1.4
Confirmation   *
Remarks
Output voltage V1
 
_05
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   3.4
Output voltage V   3 2.98 3
Confirmation   *
_06
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Output voltage V   3.05 3.05
Confirmation of operating range   *

Test data Ex:

Governor adjustment

Test data 108622-3190
N:Pump speed R:Rack position (mm) (1)Tolerance for racks not indicated: +-0.05mm. (2)Stop lever setting: R1 (3)RACK LIMIT (4)Boost compensator stroke: BCL (5)Damper spring setting
----------
R1=12.4+0.2mm BCL=2.65+-0.1mm
----------

Speed control lever angle

Test data 108622-3190
F:Full speed
----------

----------
a=11deg+-5deg

0000000901

Test data 108622-3190
F:Full load I:Idle (1)Use the hole at R = aa (2)Stopper bolt setting
----------
aa=80.5mm
----------
a=39.5deg+-3deg b=42deg+-5deg

Stop lever angle

Test data 108622-3190
N:Pump normal S:Stop the pump. (1)Use the hole at R = aa (2)Rack position bb (3)Set the stopper screw. (After setting, apply paint.)
----------
aa=33mm bb=12.4+0.2mm
----------
a=30deg+-5deg b=42deg+-5deg

0000001301

Test data 108622-3190
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)Pre-stroke: aa (4)-
----------
aa=6.4+-0.03mm
----------
a=(40deg)

0000002201 RACK SENSOR

Test data 108622-3190
(VR) measurement voltage (I) Part number of the control unit (G) Apply red paint. (H): End surface of the pump Adjustment of the rack sensor (-0720) 1. Rack limit adjustment (1)After mounting the joint (B), select the shim (D) so that the rack position is in the rack limit position. (2)Install the rod (E) to the block (C). (3)At the rack limit, set the distance between the pump end face and the rod (E) to L1. 2. Rack sensor (1)Screw in the bobbin (A) until it contacts the joint (B). (2)Fix the speed control lever at the full side and set the pump speed at N1. (3)Adjust the depth that the bobbin (A) is screwed in so that the control unit's rack sensor output voltage is VR+-0.01 (V), then tighten the nut (F). (If equipped with a boost compensator, perform with boost pressure applied.) (4)Apply red paint to both the joint (B) and the nut (F) join, and the joint (B) and the pump join. Output voltage VR +-0.01(V), speed N1, rack position Ra, rack sensor supply voltage 5+-0.01 (V)
----------
L=33.5+-0.1mm N1=550r/min Ra=10.8mm
----------




Have questions with 108622-3190?





Group cross 108622-3190 ZEXEL

Hino 

108622-3190  

108622-3191 
 
220008240A 
INJECTION-PUMP ASSEMBLY
P-4
 
220008241A 
INJECTION-PUMP ASSEMBLY
P-4
 
220008241B 
INJECTION-PUMP ASSEMBLY
P-4
 
220008242A 
INJECTION-PUMP ASSEMBLY
P-4
 
 
INJECTION-PUMP ASSEMBLY

Hino 

 
220008243A 
INJECTION-PUMP ASSEMBLY
P-4
 
220008244A 
INJECTION-PUMP ASSEMBLY
P-4
9 400 619 166 
220008245A 
INJECTION-PUMP ASSEMBLY
P-4
Back to top