108622-3183 ZEXEL F 01G 09U 0EB BOSCH INJECTION-PUMP ASSEMBLY f01g09u0eb 1086223183 220008232a


108622-3183 INJECTION-PUMP ASSEMBLY
Rating:
14
Buy INJECTION-PUMP ASSEMBLY 108622-3183 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH F 01G 09U 0EB f01g09u0eb
ZEXEL 108622-3183 1086223183
HINO 220008232A 220008232a

Cross reference number

BOSCH F 01G 09U 0EB f01g09u0eb
ZEXEL 108622-3183 1086223183
HINO 220008232A 220008232a


Zexel num
Bosch num
Firm num
Name
108622-3183 
108622-3184 
F 01G 09U 0EB 
220008232A  HINO
INJECTION-PUMP ASSEMBLY
P-3 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   134424-1520
Overflow valve opening pressure kPa   162 147 177
Overflow valve opening pressure kgf/cm2   1.65 1.5 1.8
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
PS/ACT control unit part no.   407980-2 24*
Digi switch no.   31
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-4-2-6- 3-5
Pre-stroke mm   6.4 6.37 6.43
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-4
deg.   60 59.75 60.25
Difference between angles 2
Cyl.1-2
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cal 1-3
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-5
deg.   300 299.75 300.25
Injection quantity adjustment
Adjusting point   A
Rack position   8.9
Pump speed r/min   550 550 550
Average injection quantity mm3/st.   151.7 149.7 153.7
Max. variation between cylinders %   0 -2 2
Basic   *
Fixing the lever   *
Boost pressure kPa   40.7 40.7
Boost pressure mmHg   305 305
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   6.3+-0.0 3
Remarks
Refer to items regarding the pre-stroke actuator
 
Injection quantity adjustment_02
Adjusting point   B
Rack position   9.35
Pump speed r/min   1075 1075 1075
Average injection quantity mm3/st.   153 150 156
Fixing the lever   *
Boost pressure kPa   40.7 40.7
Boost pressure mmHg   305 305
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   6.3+-0.0 3
Injection quantity adjustment_03
Adjusting point   C
Rack position   -
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   194 189 199
Fixing the lever   *
Boost pressure kPa   40.7 40.7
Boost pressure mmHg   305 305
Rack limit   *
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   6.3+-0.0 3
Injection quantity adjustment_04
Adjusting point   D
Rack position   4+-0.5
Pump speed r/min   225 225 225
Average injection quantity mm3/st.   12.5 9.5 15.5
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   6.3+-0.0 3
Injection quantity adjustment_05
Adjusting point   E
Rack position   7.8
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   132.2 129.2 135.2
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   6.3+-0.0 3
Injection quantity adjustment_06
Adjusting point   F
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   134 134
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   6.3+-0.0 3
Injection quantity adjustment_07
Adjusting point   G
Rack position   9.1
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   150.8 147.8 153.8
Fixing the lever   *
Boost pressure kPa   40.7 40.7
Boost pressure mmHg   305 305
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   6.3+-0.0 3
Boost compensator adjustment
Pump speed r/min   550 550 550
Rack position   7.8
Boost pressure kPa   9.3 7.3 9.3
Boost pressure mmHg   70 55 70
Boost compensator adjustment_02
Pump speed r/min   550 550 550
Rack position   8.9
Boost pressure kPa   27.3 27.3 27.3
Boost pressure mmHg   205 205 205
0000001601
Pre-stroke mm   6.4 6.37 6.43
Remarks
When the timing sleeve is pushed up
 
_02
Connector angle deg.   5 4.5 5.5
Remarks
When the eccentric pin is tightened
 
_03
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   4 3.95 4.05
Output voltage V   2.62 2.61 2.63
Adjustment   *
_04
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   6.4 6.37 6.43
Output voltage V   1.2 1 1.4
Confirmation   *
Remarks
Output voltage V1
 
_05
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   3.4
Output voltage V   3 2.98 3
Confirmation   *
_06
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Output voltage V   3.05 3.05
Confirmation of operating range   *

Test data Ex:

Governor adjustment

Test data 108622-3183
N:Pump speed R:Rack position (mm) (1)Tolerance for racks not indicated: +-0.05mm. (2)Set idle at point K (N = N1, R = R1) and confirm that the injection quantity does not exceed Q1 at point J (N = N2). (3)Stop lever setting: R2 (4)RACK LIMIT (5)Boost compensator stroke: BCL (6)Damper spring setting
----------
N1=325r/min R1=4mm N2=1100r/min Q1=3mm3/st R2=12.4+0.2mm BCL=1.1+-0.1mm
----------

Speed control lever angle

Test data 108622-3183
F:Full speed
----------

----------
a=12deg+-5deg

0000000901

Test data 108622-3183
F:Full load I:Idle (1)Use the hole at R = aa (2)Stopper bolt setting
----------
aa=91mm
----------
a=32deg+-3deg b=34.5+-5deg

Stop lever angle

Test data 108622-3183
N:Pump normal S:Stop the pump. (1)Use the hole at R = aa (2)Set the rack position at bb before adjusting the governor (3)Set the stopper screw. (After setting, apply paint.)
----------
aa=33mm bb=12.4+0.2mm
----------
a=30deg+-5deg b=42deg+-5deg

0000001301

Test data 108622-3183
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)Pre-stroke: aa (4)-
----------
aa=6.4+-0.03mm
----------
a=(40deg)

0000001901

Test data 108622-3183
(A): Pre-stroke actuator (B): Stamp housings A and B at the same time. (C): Stamping range 1. When installing the pre-stroke actuator on the pump, first tighten the installation bolts loosely, then move the actuator fully clockwise (viewed from the drive side). Temporary tightening torque: 1 - 1.5 N.m (0.1 - 0.15 kgf.m) 2. Move the actuator in the counterclockwise direction when viewed from the drive side, and adjust so that it becomes the adjustment point of the adjustment value. Then tighten it. Tightening torque: 7^9 N.m (0.7^0.9 kgf.m) 3. After prestroke actuator installation adjustment, simultaneously stamp both the actuator side and housing side.
----------

----------

0000002201 RACK SENSOR

Test data 108622-3183
(VR) measurement voltage (I) Part number of the control unit (G) Apply red paint. (H): End surface of the pump Adjustment of the rack sensor (-0720) 1. Rack limit adjustment (1)After mounting the joint (B), select the shim (D) so that the rack position is in the rack limit position. (2)Install the rod (E) to the block (C). (3)At the rack limit, set the distance between the pump end face and the rod (E) to L1. 2. Rack sensor (1)Screw in the bobbin (A) until it contacts the joint (B). (2)Fix the speed control lever at the full side and set the pump speed at N1. (3)Adjust the depth that the bobbin (A) is screwed in so that the control unit's rack sensor output voltage is VR+-0.01 (V), then tighten the nut (F). (If equipped with a boost compensator, perform with boost pressure applied.) (4)Apply red paint to both the joint (B) and the nut (F) join, and the joint (B) and the pump join. Output voltage VR +-0.01(V), speed N1, rack position Ra, rack sensor supply voltage 5+-0.01 (V)
----------
L=33.5+-0.1mm N1=550r/min Ra=8.9mm
----------

0000002301 GOVERNOR TORQUE CONTROL

Test data 108622-3183
Dr:Torque control stroke (A): Without torque control spring capsule 1. Adjustment procedures (1)Procedure is the same as that for the RFD (former type), except that the positive torque control stroke must be determined at the full lever setting. 2. Procedures for adjustment (1)Remove the torque control spring capsule. (2)Operate the pump at approximately N1. (End of idling spring operation < N1.) (3)Tilt the lever to the full side. (4)Set so that R = RF. (5)Increase the speed by pushing in the screw (attached to the bracket on the rear of the tension lever) through the adjusting window. (6)Adjust so that the torque control stroke Dr1 can be obtained. (7)Align N2 and N3 with the torque control spring capsule. 3. Final confirmation (1)After final confirmation, temporarily set the load lever to N = N1, R = idling position. (2)From this condition, increase speed to N = N4. (3)Confirm that positive torque control stroke is Dr2.
----------
N1=500r/min N2=(775)r/min N3=(935)r/min N4=1100r/min RF=8.9mm Dr1=0.45mm Dr2=0+0.3mm
----------




Have questions with 108622-3183?





Group cross 108622-3183 ZEXEL

Hino 

 
220008230A 
INJECTION-PUMP ASSEMBLY
P-3
 
220008231A 
INJECTION-PUMP ASSEMBLY
P-3
 
220008231B 
INJECTION-PUMP ASSEMBLY
P-3
108622-3183  

108622-3184 
F 01G 09U 0EB 
220008232A 
INJECTION-PUMP ASSEMBLY
P-3
F 01G 09U 0EC 
 
INJECTION-PUMP ASSEMBLY

Hino 

F 01G 09U 0ED 
220008233A 
INJECTION-PUMP ASSEMBLY
P-3
F 01G 09U 0EE 
220008234A 
INJECTION-PUMP ASSEMBLY
P-3
9 400 619 165 
220008235A 
INJECTION-PUMP ASSEMBLY
P-3