108622-1270 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1086221270


108622-1270 INJECTION-PUMP ASSEMBLY
Rating:
66
Buy INJECTION-PUMP ASSEMBLY 108622-1270 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 108622-1270 1086221270

Service parts 108622-1270 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 108062-4070
3. GOVERNOR 105960-0420
4. SUPPLY PUMP 105237-5710
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105664-2570
7. COUPLING PLATE
10. NOZZLE AND HOLDER ASSY 105110-8260
11. Nozzle and Holder 1-15300-424-0
12. Open Pre:MPa(Kqf/cm2) 17.7{180}/22.1{225}
13. NOZZLE-HOLDER 105041-4400
14. NOZZLE
15. NOZZLE SET 105019-2800

Include in #1:

108622-1270 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 108622-1270 1086221270


Zexel num
Bosch num
Firm num
Name
108622-1270 
 
   
INJECTION-PUMP ASSEMBLY

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8250
Bosch type code   1 688 901 101
Nozzle   105780-0120
Bosch type code   1 688 901 990
Nozzle holder   105780-2190
Opening pressure MPa   20.7
Opening pressure kgf/cm2   211
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   131424-7120
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
RED4 control unit part number   407915-0 590
RED4 rack sensor specifications mm   19
PS/ACT control unit part no.   407980-2 24*
Digi switch no.   32
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   8.5 8.47 8.53
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.75 60.25
Difference between angles 2
Cal 1-3
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cyl.1-2
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-4
deg.   300 299.75 300.25
Injection quantity adjustment
Rack position   (13.8)
PWM %   66
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   191.5 189.5 193.5
Max. variation between cylinders %   0 -3 3
Basic   *
PS407980-224* V   2.2+-0.0 1
PS407980-224* mm   6.1+-0.0 5
Injection quantity adjustment_02
Rack position   (6.4)
PWM %   24.4+-2. 8
Pump speed r/min   375 375 375
Average injection quantity mm3/st.   13.9 10.7 17.1
Max. variation between cylinders %   0 -13 13
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   8.4+-0.0 3
Remarks
Refer to items regarding the pre-stroke actuator
 
0000001201
Pre-stroke mm   8.5 8.47 8.53
Remarks
When the timing sleeve is pushed up
 
_02
Connector angle deg.   11.5 11 12
Remarks
When the eccentric pin is tightened
 
_03
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   4.5 4.45 4.55
Output voltage V   2.95 2.94 2.96
Adjustment   *
_04
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   8.5 8.47 8.53
Output voltage V   1.2 1 1.4
Confirmation   *
Remarks
Output voltage V1
 
_05
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Output voltage V   3.05 3.05
Confirmation of operating range   *

Test data Ex:

Speed control lever angle

Test data 108622-1270
N:Pump normal S:Stop the pump. (1)Rack position = aa (2)Rack position bb
----------
aa=20mm bb=1mm
----------
a=37deg+-5deg b=52deg+-5deg

0000000901

Test data 108622-1270
(1)Pump vertical direction (2)Positions of coupling's threaded installation holes at No 1 cylinder's beginning of injection (3)At the No 1 cylinder's beginning of injection position, stamp an aligning mark on the damper to align with the pointer's groove. (4)Damper (5)Pointer (6)B.T.D.C.: aa (7)Pre-stroke: bb
----------
aa=1deg bb=8.5+-0.03mm
----------
a=(50deg) b=(44deg)

0000001501

Test data 108622-1270
A:Sealing position B:Pre-stroke actuator 1. When installing the pre-stroke actuator on the pump, first tighten the installation bolts loosely, then move the actuator fully counterclockwise (viewed from the drive side). Temporary tightening torque: 1 - 1.5 N.m (0.1 - 0.15 kgf.m) 2. Move the actuator in the clockwise direction when viewed from the drive side, and adjust so that it becomes the adjustment point of the adjustment value. Then tighten it. Tightening torque: 7^9 N.m (0.7^0.9 kgf.m) 3. After prestroke actuator installation adjustment, simultaneously stamp both the actuator side and housing side.
----------

----------

0000001701

Test data 108622-1270
(PWM) Pulse width modulation (%) (R) Rack position (mm) Rack sensor output characteristics 1. Rack limit adjustment (1)Measure the rack position R2 for PWM a2%. (2)Confirm that it is within the range R2 = 15+-1 mm. (3)Measure the rack position R1 at PWM a %. (4)Confirm that it is within the range R2 - R1 = 10+-0.1 mm. 2. Check the limp home operation. (1)Move the switch box's limp home switch to the limp home side. (2)Confirm rack position L1 (mm ) and L2 (mm) for PWM in the above table. 3. Check the pull down operation. (1)Confirm that the rack position is 19 mm at PWM B%. (2)In the conditions described in the above table, move the switch box's pull down switch to the pull down side and confirm that the rack position momentarily becomes 1 mm or less.
----------
a1=16.25 % a2=72.5 % L1=1-- mm L2=19++mm A=5 % B=95 %
----------




Have questions with 108622-1270?





Group cross 108622-1270 ZEXEL

108622-1270  
 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

 
1156033770 
INJECTION-PUMP ASSEMBLY
6SD1-TC
9 400 619 126 
1156033771 
INJECTION-PUMP ASSEMBLY
6SD1-TC
F 019 Z10 304 
1156033772 
INJECTION-PUMP ASSEMBLY
6SD1-TC
F 019 Z10 910 
8976097260 
INJECTION-PUMP ASSEMBLY
6SD1-TC
F 01G 09U 1HZ 
8976109290 
INJECTION-PUMP ASSEMBLY
6SD1-TC
Back to top