107692-1402 ZEXEL 9 400 612 593 BOSCH INJECTION-PUMP ASSEMBLY 9400612593 1076921402 8943926901


107692-1402 INJECTION-PUMP ASSEMBLY
Rating:
15
Buy INJECTION-PUMP ASSEMBLY 107692-1402 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 612 593 9400612593
ZEXEL 107692-1402 1076921402
ISUZU 8943926901 8943926901

Service parts 107692-1402 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 107069-0460
3. GOVERNOR 105933-1151
4. SUPPLY PUMP 105237-6490
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105662-1650
7. COUPLING PLATE
10. NOZZLE AND HOLDER ASSY 105110-7753
11. Nozzle and Holder 8-94390-795-4
12. Open Pre:MPa(Kqf/cm2) 18.1{185}/22.1{225}
13. NOZZLE-HOLDER 105041-2131
14. NOZZLE
15. NOZZLE SET 105019-2200

Include in #1:

107692-1402 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 612 593 9400612593
ZEXEL 107692-1402 1076921402
ISUZU 8943926901 8943926901


Zexel num
Bosch num
Firm num
Name
107692-1402 
107692-1403 
9 400 612 593 
8943926901  ISUZU
INJECTION-PUMP ASSEMBLY
6HH1 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8250
Bosch type code   1 688 901 101
Nozzle   105780-0120
Bosch type code   1 688 901 990
Nozzle holder   105780-2190
Opening pressure MPa   20.7
Opening pressure kgf/cm2   211
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   131425-1820
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
PS/ACT control unit part no.   407980-2 24*
Digi switch no.   17
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   5.1 5.07 5.13
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.75 60.25
Difference between angles 2
Cal 1-3
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cyl.1-2
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-4
deg.   300 299.75 300.25
Injection quantity adjustment
Adjusting point   -
Rack position   13.8
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   116 114.4 117.6
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
PS407980-224* V   2.25+-0. 01
PS407980-224* mm   3.1+-0.0 5
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   Z
Rack position   8.5+-0.5
Pump speed r/min   360 360 360
Average injection quantity mm3/st.   12 10.7 13.3
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   5+-0.03
Standard for adjustment of the maximum variation between cylinders   *
Remarks
Refer to items regarding the pre-stroke actuator
 
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(13.8)
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   116 115 117
Basic   *
Fixing the lever   *
PS407980-224* V   2.25+-0. 01
PS407980-224* mm   3.1+-0.0 5
Injection quantity adjustment_04
Adjusting point   B
Rack position   (R1+2.4) +-0.02
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   121 111 131
Fixing the lever   *
PS407980-224* V   2.25+-0. 01
PS407980-224* mm   3.1+-0.0 5
0000001601
CU407980-224*   *
Actuator retarding type   *
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   2 1.95 2.05
Output voltage V   2.83 2.82 2.84
Adjustment   *
_02
CU407980-224*   *
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Pre-stroke mm   5.1 5.07 5.13
Output voltage V   1.2 1 1.4
Confirmation   *
Remarks
Output voltage V1
 
_03
CU407980-224*   *
Supply voltage V   24 23.5 24.5
Ambient temperature degC   23 18 28
Output voltage V   3.05 3.05
Confirmation of operating range   *

Test data Ex:

Governor adjustment

Test data 107692-1402
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm.
----------
T1=AF71
----------

Speed control lever angle

Test data 107692-1402
F:Full speed I:Idle (1)Use the pin at R = aa (2)Stopper bolt set position 'H'
----------
aa=68mm
----------
a=17deg+-5deg b=39.5deg+-3deg

Stop lever angle

Test data 107692-1402
N:Pump normal S:Stop the pump. (1)Set the stopper bolt at speed = aa and rack position = bb. (2)Use the pin above R = cc
----------
aa=0r/min bb=1.5+-0.3mm cc=40mm
----------
a=44deg+-5deg b=44deg+-5deg

0000001301

Test data 107692-1402
(1)Pump vertical direction (2)Positions of coupling's threaded installation holes at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)Pre-stroke: bb
----------
aa=6deg bb=5.1+-0.03mm
----------
a=(140deg)

0000001401

Test data 107692-1402
(1)Pointer (2)Injection timing aligning mark (3)Fly weight (4)The actual shape and direction may be different from this illustration. Operation sequence 1. Turn the prestroke actuator OFF. 2. Turn the camshaft as far as the No.1 cylinder's beginning of injection position. 3. Check that the pointer alignment mark of the injection pump and the alignment mark of the flywheel are matching. 4. If they are not matching, erase the alignment mark on the flywheel side, and stamp an alignment mark on the flywheel position that matches with the pointer side alignment mark. 5. Check again that the coupling's key groove position is in the No.1 cylinder's beginning of injection position.
----------

----------

0000001701

Test data 107692-1402
A : Stopper pin B: Connector
----------

----------

0000001801

Test data 107692-1402
C:Shim
----------

----------

0000001901

Test data 107692-1402
A:Sealing position B:Pre-stroke actuator 1. When installing the pre-stroke actuator on the pump, first tighten the installation bolts loosely, then move the actuator fully clockwise (viewed from the drive side). Temporary tightening torque: 1 - 1.5 N.m (0.1 - 0.15 kgf.m) 2. Move the actuator in the counterclockwise direction when viewed from the drive side, and adjust so that it becomes the adjustment point of the adjustment value. Then tighten it. Tightening torque: 7^9 N.m (0.7^0.9 kgf.m) 3. After prestroke actuator installation adjustment, simultaneously stamp both the actuator side and housing side.
----------

----------

0000002201 RACK SENSOR

Test data 107692-1402
G:Red paint H:Pump end face P/N: part number of suitable shim (1)Threaded type rack block (2)Welded type rack block Rack sensor adjustment 1. Threaded type rack sensor (-5*20, P type, no TICS rack limit). (1)Screw in the bobbin (A) until it contacts the joint (B). (2)Fix the pump lever. (3)At speed N1 and rack position Ra, adjust the amount that the bobbin is screwed in so that the amp's output voltage is V1. (4)Fix using the nut (F). (5)Affix the caution plate to the upper part of the joint (B). (6)Apply (G) at two places. Connecting part between the joint (B) and the nut (F) Connecting part between the end surface of the pump (H) and the joint (B) 2. Range for screw-in adjustment between the bobbin (A) and the joint (B) is 9 threads. Screw in to the end from (the position where the bobbin (A) is rotated 9 turns). Speed N1, rack position Ra, output voltage V1, rack sensor supply voltage 5+-0.01 (V)
----------
Ra=R1(13.8)+2.4mm N1=1450r/min V1=3+-0.01V
----------

0000002301 AIR CYLINDER

Test data 107692-1402
(a) Air cylinder (b) Speed lever (c) Lock nut 1. Air cylinder adjustment procedure (1)Set the speed lever B in the idle position. (2)Turn the air cylinder A ON. (3)Screw in the air cylinder (a) (4)Set the speed lever B so that the speed is N1 and the rack position is Ra. (5)After setting, turn the air cylinder A off. (6)Confirm that the distance between the speed lever B and the air cylinder A is approximately L.
----------
N1=325r/min Ra=8.5+-0.1mm L=1mm
----------




Have questions with 107692-1402?





Group cross 107692-1402 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

9 400 611 961 
8943926900 
INJECTION-PUMP ASSEMBLY
6HH1
107692-1402  

107692-1403 
9 400 612 593 
8943926901 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 619 013 
8943926902 
INJECTION-PUMP ASSEMBLY
6HH1
 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

9 400 611 638 
8943923901 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 611 404 
8943923902 
INJECTION-PUMP ASSEMBLY
6HH1
F 019 Z10 752 
8943923903 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 619 014 
8943923904 
INJECTION-PUMP ASSEMBLY
6HH1
 
8976000050 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 611 482 
8976000051 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 611 639 
8976000052 
INJECTION-PUMP ASSEMBLY
6HH1
 
 
INJECTION-PUMP ASSEMBLY
6HH1

Isuzu 

9 400 619 015 
8976000053 
INJECTION-PUMP ASSEMBLY
6HH1
 
8976000060 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 611 560 
8976000061 
INJECTION-PUMP ASSEMBLY
6HH1
 
 
INJECTION-PUMP ASSEMBLY
6HH1

Isuzu 

 
8976000062 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 619 785 
 
INJECTION-PUMP ASSEMBLY
6HH1

Isuzu 

 
8943924960 
INJECTION-PUMP ASSEMBLY
6HH1
F 019 Z10 753 
8943924961 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 619 016 
8943924962 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 611 640 
8976000800 
INJECTION-PUMP ASSEMBLY
6HH1
 
 
INJECTION-PUMP ASSEMBLY
6HH1

Isuzu 

9 400 619 017 
8976000801 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 611 641 
8976003240 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 611 642 
 
INJECTION-PUMP ASSEMBLY
6HH1

Isuzu 

 
8976005760 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 612 389 
8976005761 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 619 018 
8976005762 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 611 728 
 
INJECTION-PUMP ASSEMBLY
6HH1

Isuzu 

 
8976005770 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 612 594 
8976005771 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 619 019 
8976005772 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 611 643 
 
INJECTION-PUMP ASSEMBLY
6HH1

Isuzu 

 
8976005780 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 612 390 
8976005781 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 619 020 
8976005782 
INJECTION-PUMP ASSEMBLY
6HH1
Back to top