Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8250
Bosch type code   1 688 901 101
Nozzle   105780-0120
Bosch type code   1 688 901 990
Nozzle holder   105780-2190
Opening pressure MPa   20.7
Opening pressure kgf/cm2   211
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   131425-0520
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
PS/ACT control unit part no.   407910-3 03*
Selector switch no.   00
PS/ACT control unit part no.   407980-2 24*
Digi switch no.   11
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   1.9 1.87 1.93
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.75 60.25
Difference between angles 2
Cal 1-3
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cyl.1-2
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-4
deg.   300 299.75 300.25
Injection quantity adjustment
Adjusting point   -
Rack position   14.3
Pump speed r/min   750 750 750
Average injection quantity mm3/st.   120.5 118.9 122.1
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
PS407980-224* V   1.88+-0. 01
PS407980-224* mm   3.2+-0.0 5
PS407910-303* V   1.88+-0. 01
PS407910-303* mm   3.2+-0.0 5
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   Z
Rack position   9+-0.5
Pump speed r/min   420 420 420
Average injection quantity mm3/st.   19 17.7 20.3
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
PS407980-224* V   V1-0.05+ -0.01
PS407980-224* mm   4.9+-0.0 3
PS407910-303* V   V1-0.05+ -0.01
PS407910-303* mm   4.9+-0.0 3
Standard for adjustment of the maximum variation between cylinders   *
Remarks
Refer to items regarding the pre-stroke actuator
 
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(14.3)
Pump speed r/min   750 750 750
Average injection quantity mm3/st.   120.5 119.5 121.5
Basic   *
Fixing the lever   *
Boost pressure kPa   61.3 61.3
Boost pressure mmHg   460 460
PS407980-224* V   1.88+-0. 01
PS407980-224* mm   3.2+-0.0 5
PS407910-303* V   1.88+-0. 01
PS407910-303* mm   3.2+-0.0 5
Boost compensator adjustment
Pump speed r/min   300 300 300
Rack position   R2-2.7
Boost pressure kPa   17.3 16 18.6
Boost pressure mmHg   130 120 140
Boost compensator adjustment_02
Pump speed r/min   300 300 300
Rack position   R2(R1-0. 55)
Boost pressure kPa   48 48 48
Boost pressure mmHg   360 360 360
0000001601
CU407980-224*   *
Actuator advancing type   *
Supply voltage V   12 11.5 12.5
Ambient temperature degC   23 18 28
Pre-stroke mm   5 4.95 5.05
Output voltage V   2.83 2.82 2.84
Adjustment   *
Remarks
Output voltage V1
 
_02
CU407980-224*   *
Supply voltage V   12 11.5 12.5
Ambient temperature degC   23 18 28
Pre-stroke mm   1.9 1.87 1.93
Output voltage V   1.2 1 1.4
Confirmation   *
_03
CU407980-224*   *
Supply voltage V   12 11.5 12.5
Ambient temperature degC   23 18 28
Output voltage V   3.05 3.05
Confirmation of operating range   *
_04
CU407910-303*   *
Actuator advancing type   *
Supply voltage V   12 11.5 12.5
Ambient temperature degC   23 18 28
Pre-stroke mm   5 4.95 5.05
Output voltage V   2.83 2.82 2.84
Adjustment   *
Remarks
Output voltage V1
 
_05
CU407910-303*   *
Supply voltage V   12 11.5 12.5
Ambient temperature degC   23 18 28
Pre-stroke mm   1.9 1.87 1.93
Output voltage V   1.2 1 1.4
Confirmation   *
_06
CU407910-303*   *
Supply voltage V   12 11.5 12.5
Ambient temperature degC   23 18 28
Output voltage V   3.05 3.05
Confirmation of operating range   *

Test data Ex:

Governor adjustment

Test data 107692-1153
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)Boost compensator stroke: BCL
----------
T1=AB47 BCL=2.7+-0.1mm
----------

Speed control lever angle

Test data 107692-1153
F:Full speed I:Idle (1)Stopper bolt setting (2)Use the pin at R = aa
----------
aa=35mm
----------
a=2deg+-5deg b=33.5deg+-3deg

Stop lever angle

Test data 107692-1153
N:Pump normal S:Stop the pump. (1)- (2)Set the stopper bolt at speed = aa and rack position = bb and confirm non-injection. (3)Use the pin above R = cc
----------
aa=0r/min bb=1.5+-0.3mm cc=40mm
----------
a=12deg+-5deg b=44deg+-5deg

0000001301

Test data 107692-1153
(1)Pump vertical direction (2)Position of flywheel's threaded hole at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)Pre-stroke: bb
----------
aa=19deg bb=1.9+-0.03mm
----------
a=(60deg)

0000001401

Test data 107692-1153
(1)Pointer (2)Injection timing aligning mark (3)Fly weight (4)The actual shape and direction may be different from this illustration. Operation sequence 1. Turn the prestroke actuator OFF. 2. Turn the camshaft as far as the No.1 cylinder's beginning of injection position. 3. Check that the pointer alignment mark of the injection pump and the alignment mark of the flywheel are matching. 4. If they are not matching, erase the alignment mark on the flywheel side, and stamp an alignment mark on the flywheel position that matches with the pointer side alignment mark. 5. Check again that the coupling's key groove position is in the No.1 cylinder's beginning of injection position.
----------

----------

0000001701

Test data 107692-1153
A : Stopper pin B: Connector
----------

----------

0000001801

Test data 107692-1153
C:Shim
----------

----------

0000001901

Test data 107692-1153
A:Sealing position B:Pre-stroke actuator 1. When installing the pre-stroke actuator on the pump, first tighten the installation bolts loosely, then move the actuator fully clockwise (viewed from the drive side). Temporary tightening torque: 1 - 1.5 N.m (0.1 - 0.15 kgf.m) 2. Move the actuator in the counterclockwise direction when viewed from the drive side, and adjust so that it becomes the adjustment point of the adjustment value. Then tighten it. Tightening torque: 7^9 N.m (0.7^0.9 kgf.m) 3. After prestroke actuator installation adjustment, simultaneously stamp both the actuator side and housing side.
----------

----------

0000002201 RACK SENSOR

Test data 107692-1153
(VR) measurement voltage (I) Part number of the control unit (G) Apply red paint. (H): End surface of the pump 1. Rack sensor adjustment (-0620) (1)Fix the speed control lever at the full position (2)Set the speed to N1 r/min. (If the boost compensator is provided, apply boost pressure.) (3)Adjust the bobbin (A) so that the rack sensor's output voltage is VR+-0.01. (4)At that time, rack position must be Ra. (5)Apply G at two places. Connecting part between the joint (B) and the nut (F) Connecting part between the joint (B) and the end surface of the pump (H)
----------
N1=1250r/min Ra=R1(14.3)+2.65mm
----------

0000002301 ACS

Test data 107692-1153
(A) Set screw (B) Push rod 1 (C) Push rod 2 (D) Lever 1. Aneroid compensator unit adjustment (1)Screw in (A) to obtain L1. (2)Select C so that dimension L2 can be obtained. 2. Adjustment when mounting the governor. (1)Set the speed of the pump to N1 r/min and fix the control lever at the full set position. (2)Set to full boost. (3)Screw in the aneroid compensator body to obtain the performance shown in the graph above. (4)As there is hysterisis, measure when the absolute pressure drops. (5)Hysterisis must not exceed rack position = h1.
----------
N1=1250r/min L1=1.5+-0.5mm L2=37.5+-0.5mm h1=0.15mm
----------
Ra=R3(R1+2.65)mm Rb=R3-0.15mm Rc=R3-0.5mm P1=(89.9)+-2.7kPa((674)+-20mmHg) P2=84.7+-2.7kPa(635+-20mmHg) P3=70.1+-0.7kPa(526+-5mmHg) Q1=(131.5)cm3/1000st Q2=(130)cm3/1000st Q3=(125.5)+-2cm3/1000st




Have questions with 107692-1153?





Group cross 107692-1153 ZEXEL

9 400 619 701 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

9 400 619 624 
8943954940 
INJECTION-PUMP ASSEMBLY
6HE1-XS
 
8943954941 
INJECTION-PUMP ASSEMBLY
6HE1-XS
107692-1153  

107692-1154 
 
8943954942 
INJECTION-PUMP ASSEMBLY
6HE1-XS
9 400 619 005 
8943954943 
INJECTION-PUMP ASSEMBLY
6HE1-XS
Back to top