107492-2080 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1074922080


107492-2080 INJECTION-PUMP ASSEMBLY
Rating:
41
Buy INJECTION-PUMP ASSEMBLY 107492-2080 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 107492-2080 1074922080

Cross reference number

ZEXEL 107492-2080 1074922080


Zexel num
Bosch num
Firm num
Name
107492-2080 
 
   
INJECTION-PUMP ASSEMBLY

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8250
Bosch type code   1 688 901 101
Nozzle   105780-0120
Bosch type code   1 688 901 990
Nozzle holder   105780-2190
Opening pressure MPa   20.7
Opening pressure kgf/cm2   211
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   131425-0520
Overflow valve opening pressure kPa   255 255 255
Overflow valve opening pressure kgf/cm2   2.6 2.6 2.6
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
PS/ACT control unit part no.   407910-3 03*
Selector switch no.   02
PS/ACT control unit part no.   407980-2 24*
Digi switch no.   01
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   5.6 5.57 5.63
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.75 90.25
Difference between angles 2
Cal 1-4
deg.   180 179.75 180.25
Difference between angles 3
Cyl.1-2
deg.   270 269.75 270.25
Injection quantity adjustment
Adjusting point   -
Rack position   15.3
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   119 117.4 120.6
Max. variation between cylinders %   0 -3 3
Basic   *
Fixing the rack   *
PS407980-224* V   2.25+-0. 01
PS407980-224* mm   3.6+-0.0 5
PS407910-303* V   2.25+-0. 01
PS407910-303* mm   3.6+-0.0 5
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   Z
Rack position   8.4+-0.5
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   20 18.5 21.5
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
PS407980-224* V   V1+0.05+ -0.01
PS407980-224* mm   5.5+-0.0 3
PS407910-303* V   V1+0.05+ -0.01
PS407910-303* mm   5.5+-0.0 3
Standard for adjustment of the maximum variation between cylinders   *
Remarks
Refer to items regarding the pre-stroke actuator
 
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(15.3)
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   119 118 120
Fixing the lever   *
Boost pressure kPa   39.3 39.3
Boost pressure mmHg   295 295
PS407980-224* V   2.25+-0. 01
PS407980-224* mm   3.6+-0.0 5
PS407910-303* V   2.25+-0. 01
PS407910-303* mm   3.6+-0.0 5
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1-1.65
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   119 115 123
Fixing the lever   *
Boost pressure kPa   39.3 39.3
Boost pressure mmHg   295 295
PS407980-224* V   2.25+-0. 01
PS407980-224* mm   3.6+-0.0 5
PS407910-303* V   2.25+-0. 01
PS407910-303* mm   3.6+-0.0 5
Boost compensator adjustment
Pump speed r/min   550 550 550
Rack position   R2-1.1
Boost pressure kPa   8.7 7.4 10
Boost pressure mmHg   65 55 75
Boost compensator adjustment_02
Pump speed r/min   550 550 550
Rack position   R2[R1-2. 4]
Boost pressure kPa   26 26 26
Boost pressure mmHg   195 195 195
0000001601
CU407980-224*   *
Actuator retarding type   *
Supply voltage V   12 11.5 12.5
Ambient temperature degC   23 18 28
Pre-stroke mm   2.5 2.45 2.55
Output voltage V   2.83 2.82 2.84
Adjustment   *
_02
CU407980-224*   *
Supply voltage V   12 11.5 12.5
Ambient temperature degC   23 18 28
Pre-stroke mm   5.6 5.57 5.63
Output voltage V   1.2 1 1.4
Confirmation   *
Remarks
Output voltage V1
 
_03
CU407980-224*   *
Supply voltage V   12 11.5 12.5
Ambient temperature degC   23 18 28
Output voltage V   3.05 3.05
Confirmation of operating range   *
_04
CU407910-303*   *
Actuator retarding type   *
Supply voltage V   12 11.5 12.5
Ambient temperature degC   23 18 28
Pre-stroke mm   2.5 2.45 2.55
Output voltage V   2.83 2.82 2.84
Adjustment   *
_05
CU407910-303*   *
Supply voltage V   12 11.5 12.5
Ambient temperature degC   23 18 28
Pre-stroke mm   5.6 5.57 5.63
Output voltage V   1.2 1 1.4
Confirmation   *
Remarks
Output voltage V1
 
_06
CU407910-303*   *
Supply voltage V   12 11.5 12.5
Ambient temperature degC   23 18 28
Output voltage V   3.05 3.05
Confirmation of operating range   *

Test data Ex:

Governor adjustment

Test data 107492-2080
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)Boost compensator stroke: BCL
----------
T1=J91 BCL=1.1+-0.1mm
----------

Speed control lever angle

Test data 107492-2080
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt setting
----------
aa=40mm
----------
a=20deg+-5deg b=(36deg)+-3deg

Stop lever angle

Test data 107492-2080
N:Pump normal S:Stop the pump. (1)At pump speed aa and rack position bb, set the stopper bolt. Confirm non-injection. (2)After setting stopper bolt, confirm non-injection at pump speed cc.
----------
aa=1450r/min bb=6.2-0.5mm cc=400r/min
----------
a=36.5deg+-5deg b=(33deg)+-5deg

0000001301

Test data 107492-2080
(1)Pump vertical direction (2)Position of gear mark '3' at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)Pre-stroke: bb
----------
aa=7deg bb=5.6+-0.03mm
----------
a=(130deg)

0000001401

Test data 107492-2080
(1)Pointer (2)Injection timing aligning mark (3)Fly weight (4)The actual shape and direction may be different from this illustration. Operation sequence 1. Turn the prestroke actuator OFF. 2. Turn the camshaft as far as the No.1 cylinder's beginning of injection position. 3. Check that the pointer alignment mark of the injection pump and the alignment mark of the flywheel are matching. 4. If they are not matching, erase the alignment mark on the flywheel side, and stamp an alignment mark on the flywheel position that matches with the pointer side alignment mark. 5. Check again that the coupling's key groove position is in the No.1 cylinder's beginning of injection position.
----------

----------

0000001701

Test data 107492-2080
A : Stopper pin B: Connector
----------

----------

0000001801

Test data 107492-2080
C:Shim
----------

----------

0000001901

Test data 107492-2080
A:Sealing position B:Pre-stroke actuator 1. When installing the pre-stroke actuator on the pump, first tighten the installation bolts loosely, then move the actuator fully counterclockwise (viewed from the drive side). Temporary tightening torque: 1 - 1.5 N.m (0.1 - 0.15 kgf.m) 2. Move the actuator in the clockwise direction when viewed from the drive side, and adjust so that it becomes the adjustment point of the adjustment value. Then tighten it. Tightening torque: 7^9 N.m (0.7^0.9 kgf.m) 3. After prestroke actuator installation adjustment, simultaneously stamp both the actuator side and housing side.
----------

----------

0000002201 RACK SENSOR

Test data 107492-2080
(VR) measurement voltage (I) Part number of the control unit (G) Apply red paint. (H): End surface of the pump 1. Rack sensor adjustment (-0620) (1)Fix the speed control lever at the full position (2)Set the speed to N1 r/min. (If the boost compensator is provided, apply boost pressure.) (3)Adjust the bobbin (A) so that the rack sensor's output voltage is VR+-0.01. (4)At that time, rack position must be Ra. (5)Apply G at two places. Connecting part between the joint (B) and the nut (F) Connecting part between the joint (B) and the end surface of the pump (H)
----------
N1=1450r/min Ra=R1(15.3)mm
----------




Have questions with 107492-2080?





Group cross 107492-2080 ZEXEL

107492-2080  
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
9 400 618 849 
 
INJECTION-PUMP ASSEMBLY
4D34T3

Mitsubishi 

F 019 Z20 301 
ME015261 
INJECTION-PUMP ASSEMBLY
4D34T3
Back to top