Rating:
Information injection-pump assembly
BOSCH
9 400 618 720
9400618720
ZEXEL
106971-5250
1069715250
NISSAN-DIESEL
1680197060
1680197060
Service parts 106971-5250 INJECTION-PUMP ASSEMBLY:
1.
_
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
16600-97160
12.
Open Pre:MPa(Kqf/cm2)
15.7{160}/22.6{230}
14.
NOZZLE
Include in #1:
106971-5250
as INJECTION-PUMP ASSEMBLY
Cross reference number
BOSCH
9 400 618 720
9400618720
ZEXEL
106971-5250
1069715250
NISSAN-DIESEL
1680197060
1680197060
Zexel num
Bosch num
Firm num
Name
106971-5250
9 400 618 720
1680197060 NISSAN-DIESEL
INJECTION-PUMP ASSEMBLY
RH10F * K
RH10F * K
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8250
Bosch type code
1 688 901 101
Nozzle
105780-0120
Bosch type code
1 688 901 990
Nozzle holder
105780-2190
Opening pressure
MPa
20.7
Opening pressure
kgf/cm2
211
Injection pipe
Outer diameter - inner diameter - length (mm) mm 8-3-600
Outer diameter - inner diameter - length (mm) mm 8-3-600
Overflow valve
131425-0120
Overflow valve opening pressure
kPa
157
123
191
Overflow valve opening pressure
kgf/cm2
1.6
1.25
1.95
Tester oil delivery pressure
kPa
255
255
255
Tester oil delivery pressure
kgf/cm2
2.6
2.6
2.6
RED3 control unit part number
407910-3
960
RED3 rack sensor specifications
mm
19
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
10-9-4-3
-6-5-8-7
-2-1
Pre-stroke
mm
4.4
4.37
4.43
Beginning of injection position
Governor side NO.1
Governor side NO.1
Difference between angles 1
Cal 10-9 deg. 45 44.75 45.25
Cal 10-9 deg. 45 44.75 45.25
Difference between angles 2
Cal 10-4 deg. 72 71.75 72.25
Cal 10-4 deg. 72 71.75 72.25
Difference between angles 3
Cal 10-3 deg. 117 116.75 117.25
Cal 10-3 deg. 117 116.75 117.25
Difference between angles 4
Cal 10-6 deg. 144 143.75 144.25
Cal 10-6 deg. 144 143.75 144.25
Difference between angles 5
Cal 10-5 deg. 189 188.75 189.25
Cal 10-5 deg. 189 188.75 189.25
Difference between angles 6
Cal 10-8 deg. 216 215.75 216.25
Cal 10-8 deg. 216 215.75 216.25
Difference between angles 7
Cal 10-7 deg. 261 260.75 261.25
Cal 10-7 deg. 261 260.75 261.25
Difference between angles 8
Cal 10-2 deg. 288 287.75 288.25
Cal 10-2 deg. 288 287.75 288.25
Difference between angles 9
Cal 10-1 deg. 333 332.75 333.25
Cal 10-1 deg. 333 332.75 333.25
Injection quantity adjustment
Rack position
(13.4)
Vist
V
1.84
1.84
1.84
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
131.5
129.5
133.5
Max. variation between cylinders
%
0
-4
4
Basic
*
Injection quantity adjustment_02
Rack position
(8.8)
Vist
V
2.5
2.4
2.6
Pump speed
r/min
370
370
370
Average injection quantity
mm3/st.
16
14
18
Max. variation between cylinders
%
0
-10
10
Test data Ex:
Governor adjustment
(1)Adjusting range
(2)Step response time
(N): Speed of the pump
(L): Load
(theta) Advance angle
(Srd1) Step response time 1
(Srd2) Step response time 2
1. Adjusting conditions for the variable timer
(1)Adjust the clearance between the pickup and the protrusion to L.
----------
L=1-0.2mm N4=800r/min C4=(9deg) t1=1.7--sec. t2=1.7--sec.
----------
N1=400r/min N2=1000++r/min N3=- C1=9+-0.3deg C2=3.5++deg C3=- P1=0kPa(0kgf/cm2) P2=294kPa(3kgf/cm2) P3=392kPa(4kgf/cm2) R01=0/4load R02=4/4load R03=4/4load
----------
L=1-0.2mm N4=800r/min C4=(9deg) t1=1.7--sec. t2=1.7--sec.
----------
N1=400r/min N2=1000++r/min N3=- C1=9+-0.3deg C2=3.5++deg C3=- P1=0kPa(0kgf/cm2) P2=294kPa(3kgf/cm2) P3=392kPa(4kgf/cm2) R01=0/4load R02=4/4load R03=4/4load
Speed control lever angle
N:Pump normal
S:Stop the pump.
(1)Rack position = aa
(2)Rack position bb
----------
aa=20mm bb=1mm
----------
a=27deg+-5deg b=37deg+-5deg
----------
aa=20mm bb=1mm
----------
a=27deg+-5deg b=37deg+-5deg
0000000901
(1)Pump vertical direction
(2)Position of the coupling's key groove at the start of injection for the No. 10 cylinder.
(3)-
(4)-
----------
----------
a=(90deg)
----------
----------
a=(90deg)
Stop lever angle
(Rs) rack sensor specifications
(C/U) control unit part number
(V) Rack sensor output voltage
(R) Rack position (mm)
1. Confirming governor output characteristics (rack 19 mm, span 6 mm)
(1)When the output voltages of the rack sensor are V1 and V2, check that the rack positions R1 and R2 in the table above are satisfied.
----------
----------
----------
----------
Have questions with 106971-5250?
Group cross 106971-5250 ZEXEL
Nissan-Diesel
Nissan-Diesel
106971-5250
9 400 618 720
1680197060
INJECTION-PUMP ASSEMBLY
RH10F
RH10F