106971-5090 ZEXEL F 01G 09U 0C6 BOSCH INJECTION-PUMP ASSEMBLY f01g09u0c6 1069715090


106971-5090 INJECTION-PUMP ASSEMBLY
Rating:
46
Buy INJECTION-PUMP ASSEMBLY 106971-5090 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH F 01G 09U 0C6 f01g09u0c6
ZEXEL 106971-5090 1069715090

Service parts 106971-5090 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106097-5760
3. GOVERNOR 105952-1330
4. SUPPLY PUMP 105237-4210
5. AUTOM. ADVANCE MECHANIS 105683-0360
6. COUPLING PLATE 105663-0570
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105110-7651
11. Nozzle and Holder 16600-97160
12. Open Pre:MPa(Kqf/cm2) 15.7{160}/22.6{230}
13. NOZZLE-HOLDER 105041-3150
14. NOZZLE
15. NOZZLE SET 105019-0591

Include in #1:

106971-5090 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH F 01G 09U 0C6 f01g09u0c6
ZEXEL 106971-5090 1069715090


Zexel num
Bosch num
Firm num
Name
106971-5090 
106971-5091 
F 01G 09U 0C6 
   
INJECTION-PUMP ASSEMBLY
* K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8250
Bosch type code   1 688 901 101
Nozzle   105780-0120
Bosch type code   1 688 901 990
Nozzle holder   105780-2190
Opening pressure MPa   20.7
Opening pressure kgf/cm2   211
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   131425-0120
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
RED3 control unit part number   407910-3 960
RED3 rack sensor specifications mm   19
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   10-9-4-3 -6-5-8-7 -2-1
Pre-stroke mm   4.4 4.37 4.43
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 10-9
deg.   45 44.75 45.25
Difference between angles 2
Cal 10-4
deg.   72 71.75 72.25
Difference between angles 3
Cal 10-3
deg.   117 116.75 117.25
Difference between angles 4
Cal 10-6
deg.   144 143.75 144.25
Difference between angles 5
Cal 10-5
deg.   189 188.75 189.25
Difference between angles 6
Cal 10-8
deg.   216 215.75 216.25
Difference between angles 7
Cal 10-7
deg.   261 260.75 261.25
Difference between angles 8
Cal 10-2
deg.   288 287.75 288.25
Difference between angles 9
Cal 10-1
deg.   333 332.75 333.25
Injection quantity adjustment
Rack position   (12.6)
Vist V   1.96 1.96 1.96
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   114 112 116
Max. variation between cylinders %   0 -4 4
Basic   *
Injection quantity adjustment_02
Rack position   (8.6)
Vist V   2.6 2.5 2.7
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   16 14 18
Max. variation between cylinders %   0 -10 10
Governor adjustment
Pump speed r/min   (N1+50)- -
Advance angle deg.   0 0 0
Remarks
Start
 
Governor adjustment_02
Pump speed r/min   N1
Advance angle deg.   0.3
Remarks
Measure the actual speed.
 
Governor adjustment_03
Pump speed r/min   N2
Advance angle deg.   2 1.7 2.3
Remarks
Measure the actual speed.
 
Governor adjustment_04
Pump speed r/min   -
Advance angle deg.   2 1.7 2.3
Remarks
Measure the actual speed.
 
Governor adjustment_05
Pump speed r/min   1000
Remarks
Measure the actual advance angle.
 
Governor adjustment_06
Pump speed r/min   N4
Advance angle deg.   7 6.7 7.3
Remarks
Measure the actual speed, stop
 

Test data Ex:

Speed control lever angle

Test data 106971-5090
N:Pump normal S:Stop the pump. (1)Rack position = aa (2)Rack position bb
----------
aa=20mm bb=1mm
----------
a=20deg+-5deg b=37deg+-5deg

0000000901

Test data 106971-5090
(1)Pump vertical direction (2)Position of the coupling's key groove at the start of injection for the No. 10 cylinder. (3)- (4)-
----------

----------
a=(90deg)

Stop lever angle

Test data 106971-5090
(Rs) rack sensor specifications (C/U) control unit part number (V) Rack sensor output voltage (R) Rack position (mm) 1. Confirming governor output characteristics (rack 19 mm, span 6 mm) (1)When the output voltages of the rack sensor are V1 and V2, check that the rack positions R1 and R2 in the table above are satisfied.
----------

----------




Have questions with 106971-5090?





Group cross 106971-5090 ZEXEL

Nissan-Diesel 

9 400 618 698 
1671397176 
INJECTION-PUMP ASSEMBLY
RE10TA06
 
1671397200 
INJECTION-PUMP ASSEMBLY
D9XB
9 400 618 699 
1671397179 
INJECTION-PUMP ASSEMBLY
RD10T03
9 400 618 700 
1671397201 
INJECTION-PUMP ASSEMBLY
RF10
 
 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 400 618 701 
1680197003 
INJECTION-PUMP ASSEMBLY
D9XC
9 400 618 702 
1680197004 
INJECTION-PUMP ASSEMBLY
D9XB
9 400 618 703 
1679097063 
INJECTION-PUMP ASSEMBLY
RE10TA04
9 400 618 704 
1680197005 
INJECTION-PUMP ASSEMBLY
D9XB
F 01G 09U 0C3 
 
INJECTION-PUMP ASSEMBLY
F 01G 09U 0C4 
 
INJECTION-PUMP ASSEMBLY
F 01G 09U 0C5 
 
INJECTION-PUMP ASSEMBLY
D9XB

Nissan-Diesel 

9 400 618 705 
1680197006 
INJECTION-PUMP ASSEMBLY
RH10E
106971-5090  

106971-5091 
F 01G 09U 0C6 
 
INJECTION-PUMP ASSEMBLY
9 400 611 350 
 
INJECTION-PUMP ASSEMBLY
D9XB

Nissan-Diesel 

9 400 618 706 
1680197007 
INJECTION-PUMP ASSEMBLY
RH10E
Back to top