Rating:
Information injection-pump assembly
BOSCH
9 400 619 918
9400619918
ZEXEL
106891-1551
1068911551
ISUZU
1156032051
1156032051
Service parts 106891-1551 INJECTION-PUMP ASSEMBLY:
1.
_
6.
COUPLING PLATE
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
12.
Open Pre:MPa(Kqf/cm2)
15.7{160}/22.1{225}
15.
NOZZLE SET
Include in #1:
106891-1551
as INJECTION-PUMP ASSEMBLY
Cross reference number
BOSCH
9 400 619 918
9400619918
ZEXEL
106891-1551
1068911551
ISUZU
1156032051
1156032051
Zexel num
Bosch num
Firm num
Name
9 400 619 918
1156032051 ISUZU
INJECTION-PUMP ASSEMBLY
8PE1 * K 14CD PE8P PE
8PE1 * K 14CD PE8P PE
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 8-3-600
Outer diameter - inner diameter - length (mm) mm 8-3-600
Overflow valve
134424-4320
Overflow valve opening pressure
kPa
255
221
289
Overflow valve opening pressure
kgf/cm2
2.6
2.25
2.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-8-7-3-
6-5-4-2
Pre-stroke
mm
4.2
4.17
4.23
Rack position
Point A R=A
Point A R=A
Beginning of injection position
Governor side NO.1
Governor side NO.1
Difference between angles 1
Cal 1-8 deg. 45 44.75 45.25
Cal 1-8 deg. 45 44.75 45.25
Difference between angles 2
Cal 1-7 deg. 90 89.75 90.25
Cal 1-7 deg. 90 89.75 90.25
Difference between angles 3
Cal 1-3 deg. 135 134.75 135.25
Cal 1-3 deg. 135 134.75 135.25
Difference between angles 4
Cal 1-6 deg. 180 179.75 180.25
Cal 1-6 deg. 180 179.75 180.25
Difference between angles 5
Cal 1-5 deg. 225 224.75 225.25
Cal 1-5 deg. 225 224.75 225.25
Difference between angles 6
Cal 1-4 deg. 270 269.75 270.25
Cal 1-4 deg. 270 269.75 270.25
Difference between angles 7
Cyl.1-2 deg. 315 314.75 315.25
Cyl.1-2 deg. 315 314.75 315.25
Injection quantity adjustment
Adjusting point
A
Rack position
7.8
Pump speed
r/min
800
800
800
Average injection quantity
mm3/st.
101
99.5
102.5
Max. variation between cylinders
%
0
-2
2
Basic
*
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
C
Rack position
8.8
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
100
96
104
Fixing the lever
*
Injection quantity adjustment_03
Adjusting point
D
Rack position
4.7+-0.5
Pump speed
r/min
265
265
265
Average injection quantity
mm3/st.
10
8.7
11.3
Max. variation between cylinders
%
0
-13
13
Basic
*
Fixing the rack
*
Timer adjustment
Pump speed
r/min
800--
Advance angle
deg.
0
0
0
Remarks
Start
Start
Timer adjustment_02
Pump speed
r/min
750
Advance angle
deg.
0.3
Timer adjustment_03
Pump speed
r/min
1100
Advance angle
deg.
3.5
3
4
Remarks
Finish
Finish
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Lever ratio: RT
(2)Target shim dimension: TH
(3)Tolerance for racks not indicated: +-0.05mm.
(4)Damper spring setting: DL
----------
RT=0.8 TH=1.7mm DL=3.7-0.2mm
----------
----------
RT=0.8 TH=1.7mm DL=3.7-0.2mm
----------
Speed control lever angle
F:Full speed
----------
----------
a=7deg+-5deg
----------
----------
a=7deg+-5deg
0000000901
F:Full load
I:Idle
(1)Stopper bolt setting
----------
----------
a=10deg+-5deg b=29.5deg+-3deg
----------
----------
a=10deg+-5deg b=29.5deg+-3deg
Stop lever angle
N:Pump normal
S:Stop the pump.
(1)Use the pin at R = aa
(2)Drive side
----------
aa=23.5mm
----------
a=73deg+-5deg b=40deg+-5deg
----------
aa=23.5mm
----------
a=73deg+-5deg b=40deg+-5deg
0000001501 ACS
(A) Set screw
1. Aneroid compensator unit adjustment
Screw in (A) to obtain L1.
2. Adjustment following governor installation
(1)Set the speed of the pump to N1 r/min and fix the control lever at the full set position.
(2)Screw in the aneroid compensator to obtain the performance shown in the graph above.
----------
N1=1150r/min L1=(0.1~0.5)mm
----------
R1=7.8mm R2=7.1mm P1=(89.8)kPa((674)mmHg) P2=69.8+-0.7kPa(524+-5mmHg) Q1=120.5+-4cm3/1000st Q2=104+-10cm3/1000st
----------
N1=1150r/min L1=(0.1~0.5)mm
----------
R1=7.8mm R2=7.1mm P1=(89.8)kPa((674)mmHg) P2=69.8+-0.7kPa(524+-5mmHg) Q1=120.5+-4cm3/1000st Q2=104+-10cm3/1000st
Timing setting
(1)Pump vertical direction
(2)Position of "Z" mark at the No 1 cylinder's beginning of injection (governor side)
(3)B.T.D.C.: aa
(4)-
----------
aa=12deg
----------
a=(170deg)
----------
aa=12deg
----------
a=(170deg)