Information injection-pump assembly

BOSCH 9 400 611 043 9400611043
ZEXEL 106873-7480 1068737480
MITSUBISHI ME094508 me094508

Service parts 106873-7480 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106080-7000
3. GOVERNOR 105952-1671
4. SUPPLY PUMP 105237-0270
5. AUTOM. ADVANCE MECHANIS 105691-3890
6. COUPLING PLATE 105664-2020
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105110-7450
11. Nozzle and Holder ME093733
12. Open Pre:MPa(Kqf/cm2) 15.7{160}/21.6{220}
13. NOZZLE-HOLDER 105041-4120
14. NOZZLE
15. NOZZLE SET 105019-0620

Include in #1:

106873-7480 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 611 043 9400611043
ZEXEL 106873-7480 1068737480
MITSUBISHI ME094508 me094508


Zexel num
Bosch num
Firm num
Name
106873-7480 
9 400 611 043 
ME094508  MITSUBISHI
INJECTION-PUMP ASSEMBLY
8DC9 K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8250
Bosch type code   1 688 901 101
Nozzle   105780-0120
Bosch type code   1 688 901 990
Nozzle holder   105780-2190
Opening pressure MPa   20.7
Opening pressure kgf/cm2   211
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   131425-0220
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
RED3 control unit part number   407910-2 470
RED3 rack sensor specifications mm   15
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-2-7-3- 4-5-6-8
Pre-stroke mm   3.9 3.85 3.95
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cyl.1-2
deg.   45 44.5 45.5
Difference between angles 2
Cal 1-7
deg.   90 89.5 90.5
Difference between angles 3
Cal 1-3
deg.   135 134.5 135.5
Difference between angles 4
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 5
Cal 1-5
deg.   225 224.5 225.5
Difference between angles 6
Cal 1-6
deg.   270 269.5 270.5
Difference between angles 7
Cal 1-8
deg.   315 314.5 315.5
Injection quantity adjustment
Rack position   (10.7)
Vist V   1.86 1.86 1.86
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   125 124 126
Max. variation between cylinders %   0 -3 3
Basic   *
Injection quantity adjustment_02
Rack position   (6.5)
Vist V   2.7 2.6 2.8
Pump speed r/min   380 380 380
Average injection quantity mm3/st.   16 14 18
Max. variation between cylinders %   0 -15 15

Test data Ex:

Governor adjustment

Test data 106873-7480
(1)Adjusting range (2)Step response time (N): Speed of the pump (L): Load (theta) Advance angle (Srd1) Step response time 1 (Srd2) Step response time 2 1. Adjusting conditions for the variable timer (1)Adjust the clearance between the pickup and the protrusion to L.
----------
L=1-0.2mm N2=800r/min C2=(10deg) t1=2.5--sec. t2=2.5--sec.
----------
N1=750++r/min P1=0kPa(0kgf/cm2) P2=392kPa(4kgf/cm2) C1=10+-0.3deg R01=0/4load R02=4/4load

Speed control lever angle

Test data 106873-7480
N:Pump normal S:Stop the pump. (1)Rack position = aa (2)Rack position bb
----------
aa=16mm bb=1mm
----------
a=12deg+-5deg b=29deg+-5deg

0000000901

Test data 106873-7480
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=4deg
----------
a=(50deg)

Stop lever angle

Test data 106873-7480
(Rs) rack sensor specifications (C/U) control unit part number (V) Rack sensor output voltage (R) Rack position (mm) 1. Confirming governor output characteristics (rack 15 mm, span 6 mm) (1)When the output voltages of the rack sensor are V1 and V2, check that the rack positions R1 and R2 in the table above are satisfied.
----------

----------

0000001201 RACK SENSOR

Test data 106873-7480
(VR) measurement voltage (I) Part number of the control unit (G) Apply red paint. (H): End surface of the pump 1. Rack sensor adjustment (154610-0620) (1)At governor side rack sensor output voltage V1, adjust the bobbin (A) so that the drive side rack sensor output voltage is VR+-0.01. (2)Apply G at two places. Connecting part between the joint (B) and the nut (F) Connecting part between the joint (B) and the end surface of the pump (H)
----------
V1=1V
----------




Have questions with 106873-7480?





Group cross 106873-7480 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 618 489 
ME094459 
INJECTION-PUMP ASSEMBLY
8DC9
9 400 611 040 
ME094444 
INJECTION-PUMP ASSEMBLY
8DC8
9 400 618 490 
ME094445 
INJECTION-PUMP ASSEMBLY
8DC8
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 611 041 
ME094489 
INJECTION-PUMP ASSEMBLY
8DC9
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 618 491 
ME094490 
INJECTION-PUMP ASSEMBLY
8DC9
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 611 042 
ME162863 
INJECTION-PUMP ASSEMBLY
8M20
9 400 618 492 
ME094474 
INJECTION-PUMP ASSEMBLY
8DC9
9 400 618 493 
ME094475 
INJECTION-PUMP ASSEMBLY
8DC9
106873-7480  
9 400 611 043 
ME094508 
INJECTION-PUMP ASSEMBLY
8DC9
9 400 618 494 
ME098743 
INJECTION-PUMP ASSEMBLY
8DC9T
Back to top