106873-2510 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1068732510


106873-2510 INJECTION-PUMP ASSEMBLY
Rating:
37
Buy INJECTION-PUMP ASSEMBLY 106873-2510 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 106873-2510 1068732510

Cross reference number

ZEXEL 106873-2510 1068732510


Zexel num
Bosch num
Firm num
Name
106873-2510 
 
   
INJECTION-PUMP ASSEMBLY

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   131424-4620
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-2-7-3- 4-5-6-8
Pre-stroke mm   4.8 4.75 4.85
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cyl.1-2
deg.   45 44.5 45.5
Difference between angles 2
Cal 1-7
deg.   90 89.5 90.5
Difference between angles 3
Cal 1-3
deg.   135 134.5 135.5
Difference between angles 4
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 5
Cal 1-5
deg.   225 224.5 225.5
Difference between angles 6
Cal 1-6
deg.   270 269.5 270.5
Difference between angles 7
Cal 1-8
deg.   315 314.5 315.5
Injection quantity adjustment
Adjusting point   -
Rack position   10.7
Pump speed r/min   650 650 650
Each cylinder's injection qty mm3/st.   147.3 142.9 151.7
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   C
Rack position   6.8+-0.5
Pump speed r/min   225 225 225
Each cylinder's injection qty mm3/st.   19 16.1 21.9
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(10.7)
Pump speed r/min   650 650 650
Average injection quantity mm3/st.   147.3 146.3 148.3
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1-0.4
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   136.4 134.4 138.4
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   E
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   173 153 193
Fixing the lever   *
Remarks
After startup boost setting
 

Test data Ex:

Governor adjustment

Test data 106873-2510
N:Pump speed R:Rack position (mm) (1)Tolerance for racks not indicated: +-0.05mm. (2)Excess fuel setting for starting: SXL (3)Damper spring setting (4)When air cylinder is operating.
----------
SXL=10.9+-0.1mm
----------

Timer adjustment

Test data 106873-2510
(1)Adjusting range (2)Step response time (N): Speed of the pump (L): Load (theta) Advance angle (Srd1) Step response time 1 (Srd2) Step response time 2 1. Adjusting conditions for the variable timer (1)Adjust the clearance between the pickup and the protrusion to L.
----------
L=1-0.2mm N2=800r/min C2=(8.8)deg t1=2.5--sec. t2=2.5--sec.
----------
N1=750++r/min P1=0kPa(0kgf/cm2) P2=392kPa(4kgf/cm2) C1=8.8+-0.3deg R01=0/4load R02=4/4load

Speed control lever angle

Test data 106873-2510
F:Full speed (1)Set the pump speed at aa (2)Set the pump speed at bb. (3)Stopper bolt setting (4)Stopper bolt setting
----------
aa=1275r/min bb=865r/min
----------
a=20.5deg+-5deg b=(6.5deg)+-5deg

0000000901

Test data 106873-2510
F:Full load I:Idle (1)Stopper bolt setting
----------

----------
a=10deg+-5deg b=25.5deg+-3deg

Stop lever angle

Test data 106873-2510
N:Pump normal S:Stop the pump. (1)Rack position = aa, stopper bolt setting
----------
aa=4.3-0.5mm
----------
a=10.5deg+-5deg b=55deg+7deg-5deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=325r/min Ra=6.3+-0.1mm
----------

0000001601 RACK SENSOR

Test data 106873-2510
V1:Supply voltage V2f:Full side output voltage V2i:Idle side output voltage (A) Black (B) Yellow (C) Red (D) Trimmer (E): Shaft (F) Nut (G) Load lever 1. Load sensor adjustment (1)Connect as shown in the above diagram and apply supply voltage V1. (2)Hold the load lever (G) against the full side. (3)Turn the shaft so that the voltage between (A) and (B) is V2. (4)Hold the load lever (G) against the idle side. (5)Adjust (D) so that the voltage between (A) and (B) is V2i. (6)Repeat the above adjustments. (7)Tighten the nut (F) at the point satisfying the standards. (8)Hold the load lever against the full side stopper and the idle side stopper. (9)At this time, confirm that the full side output voltage is V2f and the idle side output voltage is V2i.
----------
V1=5+-0.02V V2f=0.15+0.03V V2i=2.35-0.03V
----------

Timing setting

Test data 106873-2510
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(40deg)




Have questions with 106873-2510?





Group cross 106873-2510 ZEXEL

Mitsubishi 

9 400 618 363 
ME092180 
INJECTION-PUMP ASSEMBLY
8DC11
106873-2510  
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

 
ME160275 
INJECTION-PUMP ASSEMBLY
8M20D
9 400 618 364 
ME092319 
INJECTION-PUMP ASSEMBLY
8DC9
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 618 365 
ME160277 
INJECTION-PUMP ASSEMBLY
8M20
 
ME092286 
INJECTION-PUMP ASSEMBLY
8DC9
9 400 613 137 
ME098649 
INJECTION-PUMP ASSEMBLY
8DC9T2
 
ME160270 
INJECTION-PUMP ASSEMBLY
8M20D
9 400 612 384 
ME092356 
INJECTION-PUMP ASSEMBLY
8DC91
9 400 618 366 
ME092357 
INJECTION-PUMP ASSEMBLY
8DC91
9 400 618 367 
ME092358 
INJECTION-PUMP ASSEMBLY
8DC91
Back to top