106873-2141 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1068732141


106873-2141 INJECTION-PUMP ASSEMBLY
Rating:
70
Buy INJECTION-PUMP ASSEMBLY 106873-2141 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 106873-2141 1068732141

Cross reference number

ZEXEL 106873-2141 1068732141


Zexel num
Bosch num
Firm num
Name
106873-2141 
 
   
INJECTION-PUMP ASSEMBLY

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-2-7-3- 4-5-6-8
Pre-stroke mm   4.8 4.75 4.85
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cyl.1-2
deg.   45 44.5 45.5
Difference between angles 2
Cal 1-7
deg.   90 89.5 90.5
Difference between angles 3
Cal 1-3
deg.   135 134.5 135.5
Difference between angles 4
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 5
Cal 1-5
deg.   225 224.5 225.5
Difference between angles 6
Cal 1-6
deg.   270 269.5 270.5
Difference between angles 7
Cal 1-8
deg.   315 314.5 315.5
Injection quantity adjustment
Adjusting point   -
Rack position   9.8
Pump speed r/min   700 700 700
Each cylinder's injection qty mm3/st.   113 109.6 116.4
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   C
Rack position   6+-0.5
Pump speed r/min   225 225 225
Each cylinder's injection qty mm3/st.   12 10.2 13.8
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(9.8)
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   113 112 114
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1(9.8)
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   116.6 111.9 121.3
Difference in delivery mm3/st.   9.4 9.4 9.4
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   D
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   135 95 175
Fixing the lever   *
Remarks
After startup boost setting
 
Timer adjustment
Pump speed r/min   880
Advance angle deg.   1.3
Load   3/4
Timer adjustment_02
Pump speed r/min   1100
Advance angle deg.   5 4.5 5.5
Load   4/4
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 106873-2141
N:Pump speed R:Rack position (mm) (1)Adjust with speed control lever at full position (minimum-maximum speed specification) (2)Adjust with the load control lever in the full position (variable speed specification). (3)Lever ratio: RT (4)Target shim dimension: TH (5)Tolerance for racks not indicated: +-0.05mm. (6)Excess fuel setting for starting: SXL (7)Damper spring setting (8)When air cylinder is operating.
----------
RT=1 TH=1.9mm SXL=12.4+-0.1mm
----------

Speed control lever angle

Test data 106873-2141
F:Full speed I:Idle (1)- (2)Air cylinder's adjustable range (3)Pump speed = aa (4)Pump speed = bb (5)Pump speed cc
----------
aa=1170r/min bb=275r/min cc=750r/min
----------
a=(11.5deg) b=(11.5deg)+-5deg c=(20deg)+-5deg d=5deg+-5deg

0000000901

Test data 106873-2141
F:Full load I:Idle (1)Stopper bolt setting
----------

----------
a=10deg+-5deg b=25deg+-3deg

Stop lever angle

Test data 106873-2141
S:Stop the pump. (1)Rack position = aa (2)Stopper bolt setting (3)Free (at shipping)
----------
aa=3.8-0.5mm
----------
a=10.5deg+-5deg b=56.5deg+7deg-5deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=325r/min Ra=5.5+-0.1mm
----------

0000001601 2-STAGE CHANGEOVER DEVICE

Test data 106873-2141
RFD governor 2 stage changeover mechanism adjustment outline (A) Bolt (B) bolt (c) Nut (D) Return spring (E) Bolt (F) Bolt (G) Screw (H) Bolt (I) Load lever (J) Speed lever (K) Air cylinder (M Air inlet Figure 1 is only for reference. Lever shape, etc, may vary. 1. Minimum-maximum speed specification adjustment (when running) (a) Without applying air to the air cylinder, loosen bolts (A) and (B). (1)High speed return L setting (a) In the speed range Nf~Nf - 300r/min, adjust using the speed adjusting bolt to determine the temporary beginning of high speed control speed. (b) Determine the rack position in the vicinity of Rf using the full load lever. (c) Increase speed and confirm return distance L. (d) Adjust using the tension lever bolt to obtain L. (2)Setting full load rack position Rf (a) Move the load control lever to the full side. (b) Adjust the full load adjusting bolt so that Rf can be obtained, then fix. (3)Setting the beginning of high speed operation Nf (a) Adjust using bolt (E) so that Nf can be obtained, and then fix. (4)Idle control setting (Re, Ni, Rc) (a) Set the speed at Ns + 200r/min and move the load control lever to the idle side. (b) Fix the lever in the position where Re can be obtained. (c) Next, decrease speed to Ni and screw in the idle spring. (d) Adjust to obtain rack position Ri. (e) Increase the speed and after confirming that the rack position is Re at Ns, set the speed at 0. (f) Confirm protrusion position Rc at idle. (5)Damper spring adjustment (a) Increase speed and set the speed at the rack position Rd - 0.1 mm (b) Set using the damper spring so that the rack position Rd can be obtained. (c) When Rd is not specified, Rd = Ri - 0.5 mm. (6)High speed droop confirmation (a) Return the load control lever to the full load lever position. (b) Increase the speed and confirm that Rf can be obtained at Nf r/min. (c) Confirm that speed is Nh at rack position Rh. 2. Variable speed specification adjustment (at operation) (a) Remove return spring (D). (b) Apply air pressure of 245~294 kPa {2.5~3 kg/cm2} to the air cylinder. (c) Perform the following adjustment in this condition. (1)Setting full load rack position Rf' (a) Pull the load lever to the idle side. (b) Obtain rack position Rf' using the nut (C). (Pump speed is Nf'-50 r/min.) (2)Setting full speed Nf' (a) Adjust using bolt (B) so that Nf can be obtained, and then fix. (3)Low speed side setting (a) At 350r/min, set bolt (F) at beginning of governor operation position, then fix. 3. Bolt (A) adjustment (1)Install return spring (D) and perform the adjustments below at air pressure 0. (a) Set at speed Nf using bolt (E). (b) Screw in bolt (A). (c) Screw in 1 more turn from the speed lever contact position (d) Fix bolt (A). (e) At this time confirm that the air cylinder's shaft moves approximately 1 mm towards the governor. 4. Lever operation confirmation using the air cylinder (1)Apply 588 kPa {6 kg/cm2} air pressure to the air cylinder. (2)Confirm that the cylinder piston is moved 50 mm by the spring (D).
----------

----------

Timing setting

Test data 106873-2141
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(40deg)




Have questions with 106873-2141?





Group cross 106873-2141 ZEXEL

Mitsubishi 

9 400 618 334 
ME091556 
INJECTION-PUMP ASSEMBLY
8DC10
9 400 612 010 
ME091557 
INJECTION-PUMP ASSEMBLY
8DC11
9 400 618 335 
ME091574 
INJECTION-PUMP ASSEMBLY
8DC11
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 618 336 
ME091524 
INJECTION-PUMP ASSEMBLY
8DC8
106873-2141  
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 618 337 
ME091525 
INJECTION-PUMP ASSEMBLY
8DC9
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 618 338 
ME091526 
INJECTION-PUMP ASSEMBLY
8DC10
F 019 Z10 013 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 618 339 
ME091527 
INJECTION-PUMP ASSEMBLY
8DC11
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 618 340 
ME091629 
INJECTION-PUMP ASSEMBLY
8DC8
9 400 618 341 
ME098625 
INJECTION-PUMP ASSEMBLY
8DC9TC
 
ME442519 
INJECTION-PUMP ASSEMBLY
8DC9TC
F 019 Z20 292 
ME442586 
INJECTION-PUMP ASSEMBLY
8DC9T
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 618 342 
ME091686 
INJECTION-PUMP ASSEMBLY
8DC11
Back to top