106871-9030 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1068719030


106871-9030 INJECTION-PUMP ASSEMBLY
Rating:
37
Buy INJECTION-PUMP ASSEMBLY 106871-9030 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 106871-9030 1068719030

Cross reference number

ZEXEL 106871-9030 1068719030


Zexel num
Bosch num
Firm num
Name
106871-9030 
106871-9035 
 
   
INJECTION-PUMP ASSEMBLY
8DC9 *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   132424-0620
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-2-7-3- 4-5-6-8
Pre-stroke mm   4.8 4.75 4.85
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cyl.1-2
deg.   45 44.5 45.5
Difference between angles 2
Cal 1-7
deg.   90 89.5 90.5
Difference between angles 3
Cal 1-3
deg.   135 134.5 135.5
Difference between angles 4
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 5
Cal 1-5
deg.   225 224.5 225.5
Difference between angles 6
Cal 1-6
deg.   270 269.5 270.5
Difference between angles 7
Cal 1-8
deg.   315 314.5 315.5
Injection quantity adjustment
Adjusting point   -
Rack position   8.8
Pump speed r/min   700 700 700
Each cylinder's injection qty mm3/st.   97 94.1 99.9
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   F
Rack position   5.8+-0.5
Pump speed r/min   450 450 450
Each cylinder's injection qty mm3/st.   17 15.3 18.7
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(8.8)
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   97 96 98
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1(8.8)
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   105.7 101.5 109.9
Difference in delivery mm3/st.   8.4 8.4 8.4
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   6.1+-0.5
Pump speed r/min   225 225 225
Each cylinder's injection qty mm3/st.   20 17 23
Fixing the rack   *
Remarks
(check)
 
Injection quantity adjustment_06
Adjusting point   E
Rack position   11.6+-0. 5
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   125 105 145
Fixing the lever   *
Remarks
Rack limit using stop lever.
 
Timer adjustment
Pump speed r/min   950--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   900
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1000
Advance angle deg.   1.7 1.2 2.2
Timer adjustment_04
Pump speed r/min   1150
Advance angle deg.   6.5 6 7
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 106871-9030
N:Pump speed R:Rack position (mm) (1)Rack limit using stop lever (2)Excess fuel setting for starting: SXL (3)Damper spring setting: DL
----------
SXL=(R1(8.8)+0.7)+0.2mm DL=4.3-0.2mm
----------

0000000901

Test data 106871-9030
F:Full load I:Idle (1)Stopper bolt setting
----------

----------
a=16deg+-5deg b=16deg+-3deg

Stop lever angle

Test data 106871-9030
N:Pump normal S:Stop the pump. (1)At rack position aa, set the stopper screw. (2)Point E setting (3)Using reverse lever (top)
----------
aa=4-0.5mm
----------
a=5deg+-6deg b=(34deg)+-6deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=325+-5r/min Ra=5.6mm
----------

Timing setting

Test data 106871-9030
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(40deg)




Have questions with 106871-9030?





Group cross 106871-9030 ZEXEL

106871-9030  

106871-9035 
 
 
INJECTION-PUMP ASSEMBLY
8DC9

Dpico 

 
 
INJECTION-PUMP ASSEMBLY
8DC9

Hyundai 

F 019 Z10 887 
 
INJECTION-PUMP ASSEMBLY
8DC9
F 019 Z10 546 
 
INJECTION-PUMP ASSEMBLY
8DC9
F 019 Z10 547 
 
INJECTION-PUMP ASSEMBLY
8DC9
9 400 618 319 
 
INJECTION-PUMP ASSEMBLY
8DC9
Back to top