106871-3450 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1068713450 220003591a


106871-3450 INJECTION-PUMP ASSEMBLY
Rating:
9
Buy INJECTION-PUMP ASSEMBLY 106871-3450 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 106871-3450 1068713450
HINO 220003591A 220003591a

Cross reference number

ZEXEL 106871-3450 1068713450
HINO 220003591A 220003591a


Zexel num
Bosch num
Firm num
Name
106871-3450 
106871-3454 
 
220003591A  HINO
INJECTION-PUMP ASSEMBLY
EF750T *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   134424-0820
Overflow valve opening pressure kPa   127.5 118 137
Overflow valve opening pressure kgf/cm2   1.3 1.2 1.4
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-8-6-2- 7-5-4-3
Pre-stroke mm   3.9 3.84 3.9
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-8
deg.   45 44.75 45.25
Difference between angles 2
Cal 1-6
deg.   90 89.75 90.25
Difference between angles 3
Cyl.1-2
deg.   135 134.75 135.25
Difference between angles 4
Cal 1-7
deg.   180 179.75 180.25
Difference between angles 5
Cal 1-5
deg.   225 224.75 225.25
Difference between angles 6
Cal 1-4
deg.   270 269.75 270.25
Difference between angles 7
Cal 1-3
deg.   315 314.75 315.25
Injection quantity adjustment
Adjusting point   A
Rack position   10.2
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   135.3 132.3 138.3
Max. variation between cylinders %   0 -4 4
Fixing the lever   *
Boost pressure kPa   20 20
Boost pressure mmHg   150 150
Injection quantity adjustment_02
Adjusting point   B
Rack position   10.9
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   155.8 153.8 157.8
Max. variation between cylinders %   0 -2 2
Basic   *
Fixing the lever   *
Boost pressure kPa   20 20
Boost pressure mmHg   150 150
Injection quantity adjustment_03
Adjusting point   C
Rack position   10.9
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   162.9 159.9 165.9
Max. variation between cylinders %   0 -4 4
Fixing the lever   *
Boost pressure kPa   20 20
Boost pressure mmHg   150 150
Injection quantity adjustment_04
Adjusting point   I
Rack position   6.5+-0.5
Pump speed r/min   225 225 225
Average injection quantity mm3/st.   17 14 20
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Injection quantity adjustment_05
Adjusting point   D
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   128 128
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Injection quantity adjustment_06
Adjusting point   E
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   140 140 160
Fixing the lever   *
Boost pressure kPa   20 20
Boost pressure mmHg   150 150
Rack limit   *
Boost compensator adjustment
Pump speed r/min   500 500 500
Rack position   9.2
Boost pressure kPa   4 1.3 6.7
Boost pressure mmHg   30 10 50
Boost compensator adjustment_02
Pump speed r/min   500 500 500
Rack position   10.2
Boost pressure kPa   10 10 12.7
Boost pressure mmHg   75 55 95
Timer adjustment
Pump speed r/min   925
Advance angle deg.   0.5
Timer adjustment_02
Pump speed r/min   950
Advance angle deg.   0.6 0.1 1.1
Timer adjustment_03
Pump speed r/min   1000
Advance angle deg.   25 24.5 25.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 106871-3450
N:Pump speed R:Rack position (mm) (1)Beginning of damper spring operation: DL (2)RACK LIMIT (3)Boost compensator stroke (at N = N1)
----------
DL=4.9-0.2mm N1=500r/min
----------

Speed control lever angle

Test data 106871-3450
F:Full speed
----------

----------
a=17deg+-5deg

0000000901

Test data 106871-3450
F:Full load I:Idle (1)Stopper bolt setting (2)R = center of hole above aa
----------
aa=50mm
----------
a=20deg+-5deg b=39deg+-3deg

Stop lever angle

Test data 106871-3450
N:Pump normal S:Stop the pump.
----------

----------
a=39deg+-5deg b=48.5deg+-3deg

0000001501 GOVERNOR TORQUE CONTROL

Test data 106871-3450
Dr:Torque control stroke (A): Without torque control spring capsule 1. Adjustment procedures (1)Procedure is the same as that for the RFD (former type), except that the positive torque control stroke must be determined at the full lever setting. 2. Procedures for adjustment (1)Remove the torque control spring capsule. (2)Operate the pump at approximately N1. (End of idling spring operation < N1.) (3)Tilt the lever to the full side. (4)Set so that R = RF. (5)Increase the speed by pushing in the screw (attached to the bracket on the rear of the tension lever) through the adjusting window. (6)Adjust so that the torque control stroke Dr1 can be obtained. (7)Align N2 and N3 with the torque control spring capsule.
----------
N1=500r/min N2=560+-30r/min N3=690-30r/min RF=10.2mm Dr1=0.7mm
----------




Have questions with 106871-3450?





Group cross 106871-3450 ZEXEL

Hino 

106871-3450  

106871-3454 
 
220003591A 
INJECTION-PUMP ASSEMBLY
EF750T
 
220003592A 
INJECTION-PUMP ASSEMBLY
EF750T
 
220003593A 
INJECTION-PUMP ASSEMBLY
EF750T
 
220003595A 
INJECTION-PUMP ASSEMBLY
EF750T
F 019 Z10 014 
220003596A 
INJECTION-PUMP ASSEMBLY
EF750T
Back to top