Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   134424-1920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-4-2-6- 3-5
Pre-stroke mm   3 2.97 3.03
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-4
deg.   60 59.75 60.25
Difference between angles 2
Cyl.1-2
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cal 1-3
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-5
deg.   300 299.75 300.25
Injection quantity adjustment
Adjusting point   A
Rack position   7.2
Pump speed r/min   1150 1150 1150
Average injection quantity mm3/st.   126 124 128
Max. variation between cylinders %   0 -4 4
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   6.8
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   108 106 110
Max. variation between cylinders %   0 -3 3
Basic   *
Fixing the lever   *
Injection quantity adjustment_03
Adjusting point   C
Rack position   4.2+-0.5
Pump speed r/min   225 225 225
Average injection quantity mm3/st.   13 9.8 16.2
Max. variation between cylinders %   0 -13 13
Fixing the rack   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 
Injection quantity adjustment_04
Adjusting point   D
Rack position   -
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   115 115
Fixing the lever   *
Remarks
After startup boost setting
 
Timer adjustment
Pump speed r/min   900+50
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1150
Advance angle deg.   5.5 5 6
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 106693-1230
N:Pump speed R:Rack position (mm) (1)Lever ratio: RT (2)Target shim dimension: TH (3)Beginning of damper spring operation: DL (4)Excess fuel setting for starting: SXL
----------
RT=0.8 TH=2.8mm DL=3.3-0.5mm SXL=8.1+0.2mm
----------

Speed control lever angle

Test data 106693-1230
F:Full speed M:Minimum-maximum speed (1)Set the pump speed at aa. (At delivery) (2)Pump speed = bb
----------
aa=1150r/min bb=550r/min
----------
a=5deg+-5deg b=(12deg)+-5deg

0000000901

Test data 106693-1230
F:Full load I:Idle (1)Stopper bolt setting (2)Attach the return spring to the upper hole and adjust.
----------

----------
a=30deg+-5deg b=31deg+-3deg

Stop lever angle

Test data 106693-1230
N:Pump normal S:Stop the pump.
----------

----------
a=32deg+-5deg b=64deg+-5deg

0000001501 GOVERNOR TORQUE CONTROL

Test data 106693-1230
Dr:Torque control stroke (A): Without torque control spring capsule 1. Adjustment procedures (1)Procedure is the same as that for the RFD (former type), except that the positive torque control stroke must be determined at the full lever setting. 2. Procedures for adjustment (1)Remove the torque control spring capsule. (2)Operate the pump at approximately N1. (End of idling spring operation < N1.) (3)Tilt the lever to the full side. (4)Set so that R = RF. (5)Increase the speed by pushing in the screw (attached to the bracket on the rear of the tension lever) through the adjusting window. (6)Adjust so that the torque control stroke Dr1 can be obtained. (7)Align N2 and N3 with the torque control spring capsule. 3. Final confirmation (1)After final confirmation, temporarily set the load lever to N = N1, R = idling position. (2)From this condition, increase speed to N = N4. (3)Confirm that positive torque control stroke is Dr2.
----------
N1=500r/min N2=600+-30r/min N3=(920)r/min N4=1100r/min RF=6.6mm Dr1=0.6mm Dr2=0+0.3mm
----------

Timing setting

Test data 106693-1230
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(70deg)




Have questions with 106693-1230?





Group cross 106693-1230 ZEXEL

Isuzu 

 
1156016121 
INJECTION-PUMP ASSEMBLY
6RA1
 
1156016301 
INJECTION-PUMP ASSEMBLY
6RB1
 
1156015801 
INJECTION-PUMP ASSEMBLY
6RB1
 
1156015802 
INJECTION-PUMP ASSEMBLY
6RB1
 
1156015803 
INJECTION-PUMP ASSEMBLY
6RB1
106693-1230  
 
1156016060 
INJECTION-PUMP ASSEMBLY
6QA1
9 400 617 904 
1156016830 
INJECTION-PUMP ASSEMBLY
6RB1
 
1156016440 
INJECTION-PUMP ASSEMBLY
6QA1
 
1156014290 
INJECTION-PUMP ASSEMBLY
6RB1
 
1156014291 
INJECTION-PUMP ASSEMBLY
6RB1
 
1156014292 
INJECTION-PUMP ASSEMBLY
6RB1
 
1156014730 
INJECTION-PUMP ASSEMBLY
6RA1
 
1156014731 
INJECTION-PUMP ASSEMBLY
6RA1
 
1156016260 
INJECTION-PUMP ASSEMBLY
6RA1
 
1156016270 
INJECTION-PUMP ASSEMBLY
6RA1
Back to top