Rating:
Information injection-pump assembly
ZEXEL
106691-6810
1066916810
ISUZU
1156010070
1156010070
Service parts 106691-6810 INJECTION-PUMP ASSEMBLY:
1.
_
6.
COUPLING PLATE
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
12.
Open Pre:MPa(Kqf/cm2)
22.1(225)
15.
NOZZLE SET
Include in #1:
106691-6810
as INJECTION-PUMP ASSEMBLY
Cross reference number
ZEXEL
106691-6810
1066916810
ISUZU
1156010070
1156010070
Zexel num
Bosch num
Firm num
Name
106691-6810
1156010070 ISUZU
INJECTION-PUMP ASSEMBLY
6RA1 * K
6RA1 * K
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 8-3-600
Outer diameter - inner diameter - length (mm) mm 8-3-600
Overflow valve
132424-0620
Overflow valve opening pressure
kPa
157
123
191
Overflow valve opening pressure
kgf/cm2
1.6
1.25
1.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-4-2-6-
3-5
Pre-stroke
mm
3
2.95
3.05
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-4 deg. 60 59.5 60.5
Cal 1-4 deg. 60 59.5 60.5
Difference between angles 2
Cyl.1-2 deg. 120 119.5 120.5
Cyl.1-2 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cal 1-3 deg. 240 239.5 240.5
Cal 1-3 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-5 deg. 300 299.5 300.5
Cal 1-5 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
A
Rack position
7.7
Pump speed
r/min
700
700
700
Average injection quantity
mm3/st.
105.7
103.7
107.7
Max. variation between cylinders
%
0
-3
3
Basic
*
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
B
Rack position
5.5+-0.5
Pump speed
r/min
225
225
225
Average injection quantity
mm3/st.
12.6
9.4
15.8
Max. variation between cylinders
%
0
-13
13
Fixing the rack
*
Injection quantity adjustment_03
Adjusting point
D
Rack position
6.3
Pump speed
r/min
700
700
700
Average injection quantity
mm3/st.
68
64
72
Max. variation between cylinders
%
0
-3
3
Fixing the lever
*
Remarks
At absolute pressure 61.3 kPa {460 mmHg}
At absolute pressure 61.3 kPa {460 mmHg}
Injection quantity adjustment_04
Adjusting point
E
Rack position
7.7
Pump speed
r/min
1150
1150
1150
Average injection quantity
mm3/st.
115.2
109.2
121.2
Max. variation between cylinders
%
0
-3
3
Fixing the lever
*
Timer adjustment
Pump speed
r/min
700
Advance angle
deg.
0.5
Timer adjustment_02
Pump speed
r/min
800
Advance angle
deg.
0.7
0.2
1.2
Timer adjustment_03
Pump speed
r/min
1000
Advance angle
deg.
2.7
2.2
3.2
Timer adjustment_04
Pump speed
r/min
1150
Advance angle
deg.
4
3.5
4.5
Timer adjustment_05
Pump speed
r/min
-
Advance angle
deg.
4.5
4
5
Remarks
Measure the actual speed, stop
Measure the actual speed, stop
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Damper spring setting: DL
(2)Excess fuel setting for starting: SXL
(3)Aneroid compensator absolute pressure: at P1
----------
DL=5-0.5mm SXL=7.7+0.2mm P1=61.3+-0.7kPa(460+-5mmHg)
----------
----------
DL=5-0.5mm SXL=7.7+0.2mm P1=61.3+-0.7kPa(460+-5mmHg)
----------
0000000901
F:Full load
I:Idle
S:Stop
(1)Attach the return spring to the upper hole and adjust.
(2)Set the load lever's stop position so that R = aa (N = 0).
----------
aa=5mm
----------
a=6.5deg+-5deg b=8deg+-5deg c=27deg+-3deg
----------
aa=5mm
----------
a=6.5deg+-5deg b=8deg+-5deg c=27deg+-3deg
Stop lever angle
N:Pump normal
S:Stop the pump.
----------
----------
a=32deg+-5deg b=64deg+-5deg
----------
----------
a=32deg+-5deg b=64deg+-5deg
0000001501 ACS
(A) Set screw
(B) Push rod 1
1. Aneroid compensator unit adjustment
(1)Screw in (A) to obtain L1.
2. Adjustment following governor installation
(1)Set the speed of the pump to N1 r/min and fix the control lever at the full set position.
(2)Screw in the aneroid compensator to obtain the performance shown in the graph above.
----------
N1=700r/min L1=(0.6~0.9)mm
----------
R1=7.7mm R2=6.3mm P1=(94.6)kPa((710)mmHg) P2=61.3+-0.7kPa(460+-5mmHg) Q1=105.7+-2cm3/1000st Q2=-
----------
N1=700r/min L1=(0.6~0.9)mm
----------
R1=7.7mm R2=6.3mm P1=(94.6)kPa((710)mmHg) P2=61.3+-0.7kPa(460+-5mmHg) Q1=105.7+-2cm3/1000st Q2=-
Timing setting
(1)Pump vertical direction
(2)Position of timer's threaded hole at No 1 cylinder's beginning of injection
(3)B.T.D.C.: aa
(4)-
----------
aa=19deg
----------
a=(70deg)
----------
aa=19deg
----------
a=(70deg)
Have questions with 106691-6810?
Group cross 106691-6810 ZEXEL
Isuzu
106691-6810
1156010070
INJECTION-PUMP ASSEMBLY
6RA1
6RA1