Rating:
Information injection-pump assembly
ZEXEL
106682-9000
1066829000
KOMATSU
6162732181
6162732181
Cross reference number
ZEXEL
106682-9000
1066829000
KOMATSU
6162732181
6162732181
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8130
Bosch type code
EFEP215A
Nozzle
105780-0050
Bosch type code
DN6TD119NP1T
Nozzle holder
105780-2090
Bosch type code
EFEP215
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 8-4-1000
Outer diameter - inner diameter - length (mm) mm 8-4-1000
Overflow valve
131424-7120
Overflow valve opening pressure
kPa
255
221
289
Overflow valve opening pressure
kgf/cm2
2.6
2.25
2.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left L
Left L
Injection order
1-5-3-6-
2-4
Pre-stroke
mm
3
2.95
3.05
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-5 deg. 60 59.5 60.5
Cal 1-5 deg. 60 59.5 60.5
Difference between angles 2
Cal 1-3 deg. 120 119.5 120.5
Cal 1-3 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cyl.1-2 deg. 240 239.5 240.5
Cyl.1-2 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-4 deg. 300 299.5 300.5
Cal 1-4 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
A
Rack position
17.4
Pump speed
r/min
750
750
750
Average injection quantity
mm3/st.
446
441
451
Max. variation between cylinders
%
0
-3
3
Basic
*
Fixing the rack
*
Injection quantity adjustment_02
Adjusting point
B
Rack position
9.3+-0.5
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
37
32
42
Max. variation between cylinders
%
0
-15
15
Fixing the rack
*
Injection quantity adjustment_03
Adjusting point
E
Rack position
20+1
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
500
500
Fixing the lever
*
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)RACK LIMIT not operating.
(3)Idle sub spring setting: L1.
----------
K=15 L1=9.4-0.5mm
----------
----------
K=15 L1=9.4-0.5mm
----------
Speed control lever angle
F:Full speed
I:Idle
S:Stop
(1)Stopper bolt setting
(2)Set the pump speed at aa
(3)Set speed at bb (setting at delivery), set stopper bolt.
----------
aa=750r/min bb=900r/min
----------
a=58deg+-3deg b=10deg+-5deg c=33deg+-5deg d=7deg+-5deg
----------
aa=750r/min bb=900r/min
----------
a=58deg+-3deg b=10deg+-5deg c=33deg+-5deg d=7deg+-5deg
Stop lever angle
N:Pump normal
S:Stop the pump.
(1)Confirm non-injection with stop lever at stop and N = aa.
----------
aa=200r/min
----------
a=26.5deg+-5deg b=53deg+-5deg
----------
aa=200r/min
----------
a=26.5deg+-5deg b=53deg+-5deg
Timing setting
(1)Pump vertical direction
(2)Coupling's key groove position at No 1 cylinder's beginning of injection
(3)-
(4)-
----------
----------
a=(30deg)
----------
----------
a=(30deg)