106681-1001 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1066811001 1156031141


106681-1001 INJECTION-PUMP ASSEMBLY
Rating:
48
Buy INJECTION-PUMP ASSEMBLY 106681-1001 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 106681-1001 1066811001
ISUZU 1156031141 1156031141

Service parts 106681-1001 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106068-3020
3. GOVERNOR 105923-2191
4. SUPPLY PUMP 105237-5060
5. AUTOM. ADVANCE MECHANIS 105682-0140
6. COUPLING PLATE 105664-0860
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105110-4581
11. Nozzle and Holder 1-15300-357-0
12. Open Pre:MPa(Kqf/cm2) 19.6{200}
13. NOZZLE-HOLDER 105041-3081
14. NOZZLE 105025-1120
15. NOZZLE SET

Include in #1:

106681-1001 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 106681-1001 1066811001
ISUZU 1156031141 1156031141


Zexel num
Bosch num
Firm num
Name
106681-1001 
106681-1002 
 
1156031141  ISUZU
INJECTION-PUMP ASSEMBLY
6WA1-TC * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8250
Bosch type code   1 688 901 101
Nozzle   105780-0120
Bosch type code   1 688 901 990
Nozzle holder   105780-2190
Opening pressure MPa   20.7
Opening pressure kgf/cm2   211
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   134424-4320
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3 2.97 3.03
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.75 60.25
Difference between angles 2
Cal 1-3
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cyl.1-2
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-4
deg.   300 299.75 300.25
Injection quantity adjustment
Adjusting point   -
Rack position   13
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   196 194 198
Max. variation between cylinders %   0 -3 3
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   Z
Rack position   6.5+-0.5
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   15 11.8 18.2
Max. variation between cylinders %   0 -13 13
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(13)
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   196 194 198
Basic   *
Fixing the lever   *
Boost pressure kPa   46 46
Boost pressure mmHg   345 345
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1(13)
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   168.5 162.5 174.5
Fixing the lever   *
Boost pressure kPa   46 46
Boost pressure mmHg   345 345
Boost compensator adjustment
Pump speed r/min   420 420 420
Rack position   R2-2.6
Boost pressure kPa   10 8.7 11.3
Boost pressure mmHg   75 65 85
Boost compensator adjustment_02
Pump speed r/min   420 420 420
Rack position   R2(R1-1. 6)
Boost pressure kPa   32.7 32.7 32.7
Boost pressure mmHg   245 245 245
Timer adjustment
Pump speed r/min   925--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   875
Advance angle deg.   0.3
Timer adjustment_03
Pump speed r/min   975
Advance angle deg.   2 1.5 2.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 106681-1001
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)Boost compensator stroke: BCL (4)Damper spring setting
----------
T1=AE64 BCL=2.6+-0.1mm
----------

Speed control lever angle

Test data 106681-1001
F:Full speed I:Idle (1)Use the pin at R = aa (2)Stopper bolt set position 'H'
----------
aa=32mm
----------
a=1.5deg+-5deg b=35deg+-3deg

Stop lever angle

Test data 106681-1001
N:Pump normal S:Stop the pump. (1)Use the pin at R = aa (2)Set the stopper bolt so that speed = bb and rack position = cc. (Confirm non-injection.)
----------
aa=40mm bb=0r/min cc=1+-0.3mm
----------
a=18deg+-5deg b=44deg+-5deg

Timing setting

Test data 106681-1001
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=14deg
----------
a=(90deg)




Have questions with 106681-1001?





Group cross 106681-1001 ZEXEL

Isuzu 

9 400 619 870 
1156031140 
INJECTION-PUMP ASSEMBLY
6WA1-TC
106681-1001  

106681-1002 
 
1156031141 
INJECTION-PUMP ASSEMBLY
6WA1-TC
 
1156031142 
INJECTION-PUMP ASSEMBLY
6WA1-TC
9 400 611 625 
1156031143 
INJECTION-PUMP ASSEMBLY
6WA1-TC
9 400 617 483 
1156031144 
INJECTION-PUMP ASSEMBLY
6WA1-TC
Back to top