106676-2521 ZEXEL 9 400 612 278 BOSCH INJECTION-PUMP ASSEMBLY 9400612278 1066762521


106676-2521 INJECTION-PUMP ASSEMBLY
Rating:
27
Buy INJECTION-PUMP ASSEMBLY 106676-2521 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 612 278 9400612278
ZEXEL 106676-2521 1066762521

Service parts 106676-2521 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106067-6211
3. GOVERNOR 105960-0310
4. SUPPLY PUMP 105237-4790
5. AUTOM. ADVANCE MECHANIS 105691-4210
6. COUPLING PLATE 105663-0800
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105110-8121
11. Nozzle and Holder ME440089
12. Open Pre:MPa(Kqf/cm2) 15.7{160}/21.6{220}
13. NOZZLE-HOLDER 105041-4110
14. NOZZLE
15. NOZZLE SET 105019-2670

Include in #1:

106676-2521 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 612 278 9400612278
ZEXEL 106676-2521 1066762521


Zexel num
Bosch num
Firm num
Name
106676-2521 
106676-2522 
9 400 612 278 
   
INJECTION-PUMP ASSEMBLY
* K 14CA PE6P,6PD PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   131424-8020
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
RED4 control unit part number   407915-0 590
RED4 rack sensor specifications mm   19
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.9 3.85 3.95
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Rack position   (13.4)
PWM %   63.5
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   178 175 181
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Injection quantity adjustment_02
Rack position   (7.3)
PWM %   29+-2.8
Pump speed r/min   225 225 225
Average injection quantity mm3/st.   8.5 7 10
Max. variation between cylinders %   0 -15 15

Test data Ex:

Governor adjustment

Test data 106676-2521
(1)Adjusting range (2)Step response time (N): Speed of the pump (L): Load (theta) Advance angle (Srd1) Step response time 1 (Srd2) Step response time 2 1. Adjusting conditions for the variable timer (1)Adjust the clearance between the pickup and the protrusion to L.
----------
L=1.5-0.2mm N2=800r/min C2=(10)deg t1=2.5--sec. t2=2.5--sec.
----------
N1=750r/min P1=0kPa(0kgf/cm2) P2=392kPa(4kgf/cm2) C1=10+-0.3deg R01=0/4load R02=4/4load

Speed control lever angle

Test data 106676-2521
N:Pump normal S:Stop the pump. (1)Rack position = aa (2)Rack position bb
----------
aa=20mm bb=1mm
----------
a=2deg+-5deg b=37deg+-5deg

0000000901

Test data 106676-2521
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=10deg
----------
a=(2deg)

Stop lever angle

Test data 106676-2521
(PWM) Pulse width modulation (%) (R) Rack position (mm) Rack sensor output characteristics 1. Rack limit adjustment (1)Measure the rack position R2 for PWM a2%. (2)Confirm that it is within the range R2 = 15+-1 mm. (3)Measure the rack position R1 at PWM a %. (4)Confirm that it is within the range R2 - R1 = 10+-0.1 mm. 2. Check the limp home operation. (1)Move the switch box's limp home switch to the limp home side. (2)Confirm rack position L1 (mm ) and L2 (mm) for PWM in the above table. 3. Check the pull down operation. (1)Confirm that the rack position is 19 mm at PWM B%. (2)In the conditions described in the above table, move the switch box's pull down switch to the pull down side and confirm that the rack position momentarily becomes 1 mm or less.
----------
a1=16.25% a2=72.5% L1=1--mm L2=19++mm A=5 % B=95%
----------




Have questions with 106676-2521?





Group cross 106676-2521 ZEXEL

Mitsubishi 

9 400 612 572 
ME440033 
INJECTION-PUMP ASSEMBLY
6D24-T
9 400 612 543 
ME440107 
INJECTION-PUMP ASSEMBLY
6D24
9 400 612 045 
 
INJECTION-PUMP ASSEMBLY
6D24TL
106676-2521  

106676-2522 
9 400 612 278 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 613 484 
ME158917 
INJECTION-PUMP ASSEMBLY
6D24TL
9 400 617 450 
ME440231 
INJECTION-PUMP ASSEMBLY
6D24T
9 400 617 451 
ME440232 
INJECTION-PUMP ASSEMBLY
6D24TL
9 400 612 046 
ME440233 
INJECTION-PUMP ASSEMBLY
6D24TL
9 400 613 271 
ME350752 
INJECTION-PUMP ASSEMBLY
6D24
9 400 612 379 
ME440569 
INJECTION-PUMP ASSEMBLY
6D24T
9 400 617 452 
ME440802 
INJECTION-PUMP ASSEMBLY
6D24TC
9 400 613 210 
ME440948 
INJECTION-PUMP ASSEMBLY
6D24T