106673-2530 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1066732530 me157389


106673-2530 INJECTION-PUMP ASSEMBLY
Rating:
55
Buy INJECTION-PUMP ASSEMBLY 106673-2530 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 106673-2530 1066732530
MITSUBISHI ME157389 me157389

Service parts 106673-2530 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106061-5030
3. GOVERNOR 105407-4730
4. SUPPLY PUMP 105207-1210
5. AUTOM. ADVANCE MECHANIS 105636-1880
6. COUPLING PLATE 105662-0710
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105101-5990
11. Nozzle and Holder ME050883
12. Open Pre:MPa(Kqf/cm2) 21.6{220}
13. NOZZLE-HOLDER 105031-3970
14. NOZZLE 105015-6150
15. NOZZLE SET

Include in #1:

106673-2530 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 106673-2530 1066732530
MITSUBISHI ME157389 me157389


Zexel num
Bosch num
Firm num
Name
106673-2530 
 
ME157389  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D22TC * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   131424-4620
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   4.8 4.75 4.85
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   10.5
Pump speed r/min   800 800 800
Average injection quantity mm3/st.   145.3 142.3 148.3
Max. variation between cylinders %   0 -3 3
Basic   *
Fixing the lever   *
Boost pressure kPa   49.3 49.3
Boost pressure mmHg   370 370
Injection quantity adjustment_02
Adjusting point   B
Rack position   5.8+-0.5
Pump speed r/min   275 275 275
Average injection quantity mm3/st.   15 12.4 17.6
Fixing the rack   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Remarks
(check)
 
Injection quantity adjustment_03
Adjusting point   C
Rack position   5.2+-0.5
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   15 12.4 17.6
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Boost compensator adjustment
Pump speed r/min   600 600 600
Rack position   9.3
Boost pressure kPa   6.7 5.4 8
Boost pressure mmHg   50 40 60
Boost compensator adjustment_02
Pump speed r/min   600 600 600
Rack position   10.5
Boost pressure kPa   36 29.3 42.7
Boost pressure mmHg   270 220 320
Timer adjustment
Pump speed r/min   1050--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1000
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1100
Advance angle deg.   1.5 1 2
Timer adjustment_04
Pump speed r/min   -
Advance angle deg.   2 2 2
Remarks
Measure the actual speed, stop
 

Test data Ex:

Governor adjustment

Test data 106673-2530
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)RACK LIMIT (3)Main spring setting (4)Set idle sub-spring (5)Boost compensator stroke: BCL (6)At shipping (7)Rack difference between N = N1 and N = N2
----------
K=8 BCL=1.2+-0.1mm N1=800r/min N2=300r/min
----------

Speed control lever angle

Test data 106673-2530
F:Full speed I:Idle (1)Stopper bolt setting (2)At shipping (3)Set the pump speed at aa (4)Set the pump speed at bb.
----------
aa=1100r/min bb=900r/min
----------
a=(27deg)+-5deg b=(2deg) c=(8deg)+-5deg d=(7deg)+-5deg

Stop lever angle

Test data 106673-2530
N:Pump normal S:Stop the pump. (1)Speed = aa, rack position = bb (sealed at shipping)
----------
aa=0r/min bb=1-0.2mm
----------
a=35deg+-5deg b=70deg+-5deg

Timing setting

Test data 106673-2530
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(7deg)




Have questions with 106673-2530?





Group cross 106673-2530 ZEXEL

Mitsubishi 

9 400 617 241 
ME056898 
INJECTION-PUMP ASSEMBLY
6D22T3
9 400 617 242 
ME056899 
INJECTION-PUMP ASSEMBLY
6D22T2
F 019 Z10 534 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 617 243 
ME157381 
INJECTION-PUMP ASSEMBLY
6D22T
106673-2530  
 
ME157389 
INJECTION-PUMP ASSEMBLY
6D22TC
9 400 617 244 
ME157397 
INJECTION-PUMP ASSEMBLY
6D22T
9 400 613 479 
ME056902 
INJECTION-PUMP ASSEMBLY
6D22
9 400 617 245 
ME056903 
INJECTION-PUMP ASSEMBLY
6D22
9 400 617 246 
ME056908 
INJECTION-PUMP ASSEMBLY
6D22T2
9 400 617 247 
ME157514 
INJECTION-PUMP ASSEMBLY
6D22TC
9 400 617 248 
ME157500 
INJECTION-PUMP ASSEMBLY
6D22TC
Back to top