Rating:
Information injection-pump assembly
ZEXEL
106672-3390
1066723390
HINO
220203020A
220203020a
Cross reference number
ZEXEL
106672-3390
1066723390
HINO
220203020A
220203020a
Zexel num | Bosch num | Firm num | Firm | Name |
106672-3390
106672-3391 |
220203020A | HINO |
INJECTION-PUMP ASSEMBLY
EP100T * |
Calibration Data:
Adjustment conditions Test oil ISO4113 or {SAEJ967d}
1404 Test oil
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
mm
8-3-600
Outer diameter - inner diameter - length (mm)
Outer diameter - inner diameter - length (mm)
Overflow valve
134424-1420
Overflow valve opening pressure
kPa
162
147
177
Overflow valve opening pressure
kgf/cm2
1.65
1.5
1.8
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
R
Right
Right
Injection timing adjustment Direction of rotation (viewed from drive side) R
Right
Injection order
1-4-2-6-
3-5
Pre-stroke
mm
4.5
4.4
4.5
Beginning of injection position
NO.1
Drive side
Drive side
Difference between angles 1
deg.
60
59.5
60.5
Cal 1-4
Cal 1-4
Difference between angles 2
deg.
120
119.5
120.5
Cyl.1-2
Cyl.1-2
Difference between angles 3
deg.
180
179.5
180.5
Cal 1-6
Cal 1-6
Difference between angles 4
deg.
240
239.5
240.5
Cal 1-3
Cal 1-3
Difference between angles 5
deg.
300
299.5
300.5
Cal 1-5
Cal 1-5
Injection quantity adjustment Adjusting point B
Rack position
7.3
Pump speed
r/min
650
650
650
Average injection quantity
mm3/st.
100.2
98.2
102.2
Max. variation between cylinders
%
0
-2
2
Basic
*
Fixing the lever
*
Injection quantity adjustment_02 Adjusting point C
Rack position
4.9+-0.5
Pump speed
r/min
440
440
440
Average injection quantity
mm3/st.
10.2
7.2
13.2
Max. variation between cylinders
%
0
-15
15
Fixing the rack
*
Injection quantity adjustment_03 Adjusting point D
Rack position
-
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
134
129
139
Fixing the lever
*
Rack limit
*
Test data Ex:
Governor adjustment

----------
K=13
----------
Speed control lever angle

----------
----------
a=(13deg)+-5deg b=(26deg)+-5deg
Stop lever angle

----------
----------
a=53deg+-5deg b=53deg+-5deg
Timing setting

----------
----------
a=(50deg)