Rating:
Information injection-pump assembly
ZEXEL
106672-3380
1066723380
HINO
220801460A
220801460a
Cross reference number
ZEXEL
106672-3380
1066723380
HINO
220801460A
220801460a
Zexel num | Bosch num | Firm num | Firm | Name |
106672-3380
106672-3381 |
220801460A | HINO |
INJECTION-PUMP ASSEMBLY
EP100-T A * K |
Calibration Data:
Adjustment conditions Test oil ISO4113 or {SAEJ967d}
1404 Test oil
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
mm
8-3-600
Outer diameter - inner diameter - length (mm)
Outer diameter - inner diameter - length (mm)
Overflow valve
134424-1420
Overflow valve opening pressure
kPa
162
147
177
Overflow valve opening pressure
kgf/cm2
1.65
1.5
1.8
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
RED3 control unit part number
407910-2
470
RED3 rack sensor specifications
mm
15
Direction of rotation (viewed from drive side)
R
Right
Right
Injection timing adjustment Direction of rotation (viewed from drive side) R
Right
Injection order
1-4-2-6-
3-5
Pre-stroke
mm
3.9
3.84
3.9
Beginning of injection position
NO.1
Drive side
Drive side
Difference between angles 1
deg.
60
59.75
60.25
Cal 1-4
Cal 1-4
Difference between angles 2
deg.
120
119.75
120.25
Cyl.1-2
Cyl.1-2
Difference between angles 3
deg.
180
179.75
180.25
Cal 1-6
Cal 1-6
Difference between angles 4
deg.
240
239.75
240.25
Cal 1-3
Cal 1-3
Difference between angles 5
deg.
300
299.75
300.25
Cal 1-5
Cal 1-5
Injection quantity adjustment Rack position (11.9)
Vist
V
1.61
1.61
1.61
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
114.8
112.8
116.8
Max. variation between cylinders
%
0
-2
2
Basic
*
Injection quantity adjustment_02 Rack position (7.8)
Vist
V
2.4
2.3
2.5
Pump speed
r/min
360
360
360
Average injection quantity
mm3/st.
9.5
6.5
12.5
Max. variation between cylinders
%
0
-15
15
Test data Ex:
Speed control lever angle

----------
aa=16mm bb=1mm
----------
a=19deg+-5deg b=29deg+-5deg
0000000901

----------
----------
a=(50deg)
Stop lever angle

----------
----------