Buy
INJECTION-PUMP ASSEMBLY 106672-3110 zexel
genuine, new aftermarket engine parts with delivery
Information injection-pump assembly
ZEXEL
106672-3110
1066723110
HINO
220201950A
220201950a
Cross reference number
ZEXEL
106672-3110
1066723110
HINO
220201950A
220201950a
Zexel num | Bosch num | Firm num | Firm | Name |
106672-3110
106672-3114 |
220201950A | HINO |
INJECTION-PUMP ASSEMBLY
EP100 * |
Calibration Data:
Adjustment conditions Test oil ISO4113 or {SAEJ967d}
1404 Test oil
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
mm
8-3-600
Outer diameter - inner diameter - length (mm)
Outer diameter - inner diameter - length (mm)
Overflow valve
134424-1420
Overflow valve opening pressure
kPa
162
147
177
Overflow valve opening pressure
kgf/cm2
1.65
1.5
1.8
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
R
Right
Right
Injection timing adjustment Direction of rotation (viewed from drive side) R
Right
Injection order
1-4-2-6-
3-5
Pre-stroke
mm
3.9
3.85
3.95
Beginning of injection position
NO.1
Drive side
Drive side
Difference between angles 1
deg.
60
59.5
60.5
Cal 1-4
Cal 1-4
Difference between angles 2
deg.
120
119.5
120.5
Cyl.1-2
Cyl.1-2
Difference between angles 3
deg.
180
179.5
180.5
Cal 1-6
Cal 1-6
Difference between angles 4
deg.
240
239.5
240.5
Cal 1-3
Cal 1-3
Difference between angles 5
deg.
300
299.5
300.5
Cal 1-5
Cal 1-5
Injection quantity adjustment Adjusting point A
Rack position
8.4
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
114.8
112.8
116.8
Max. variation between cylinders
%
0
-2
2
Basic
*
Fixing the lever
*
Injection quantity adjustment_02 Adjusting point B
Rack position
5.7+-0.5
Pump speed
r/min
360
360
360
Average injection quantity
mm3/st.
9.5
6.5
12.5
Max. variation between cylinders
%
0
-15
15
Fixing the rack
*
Injection quantity adjustment_03 Adjusting point C
Rack position
10+-0.5
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
140
135
145
Fixing the lever
*
Rack limit
*
Test data Ex:
Governor adjustment

----------
K=8 L1=6-0.5mm
----------
Speed control lever angle

----------
aa=900r/min bb=750r/min
----------
a=20deg+-5deg b=4deg+-5deg c=32deg+-3deg d=5deg+-5deg
Stop lever angle

----------
----------
a=27deg+-5deg b=53deg+-5deg
Timing setting

----------
----------
a=(50deg)