Rating:
Information injection-pump assembly
ZEXEL
106672-2190
1066722190
MITSUBISHI-HEAV
0429050651
0429050651
Service parts 106672-2190 INJECTION-PUMP ASSEMBLY:
1.
_
2.
FUEL INJECTION PUMP
5.
AUTOM. ADVANCE MECHANIS
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
12.
Open Pre:MPa(Kqf/cm2)
29.4{300}
15.
NOZZLE SET
Include in #1:
106672-2190
as INJECTION-PUMP ASSEMBLY
Cross reference number
ZEXEL
106672-2190
1066722190
MITSUBISHI-HEAV
0429050651
0429050651
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle
105015-3640
Bosch type code
DLL165S288NP85
Nozzle holder
105040-2140
Opening pressure
MPa
29.4
Opening pressure
kgf/cm2
300
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-1130
Outer diameter - inner diameter - length (mm) mm 6-2-1130
Overflow valve
131424-1520
Overflow valve opening pressure
kPa
157
123
191
Overflow valve opening pressure
kgf/cm2
1.6
1.25
1.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left L
Left L
Injection order
1-5-3-6-
2-4
Pre-stroke
mm
3.4
3.35
3.45
Beginning of injection position
Governor side NO.1
Governor side NO.1
Difference between angles 1
Cal 1-5 deg. 60 59.5 60.5
Cal 1-5 deg. 60 59.5 60.5
Difference between angles 2
Cal 1-3 deg. 120 119.5 120.5
Cal 1-3 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cyl.1-2 deg. 240 239.5 240.5
Cyl.1-2 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-4 deg. 300 299.5 300.5
Cal 1-4 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
A
Rack position
18
Pump speed
r/min
750
750
750
Average injection quantity
mm3/st.
330
321
339
Max. variation between cylinders
%
0
-3
3
Basic
*
Fixing the rack
*
Injection quantity adjustment_02
Adjusting point
B
Rack position
18
Pump speed
r/min
450
450
450
Average injection quantity
mm3/st.
338
328
348
Max. variation between cylinders
%
0
-5
5
Fixing the rack
*
Injection quantity adjustment_03
Adjusting point
C
Rack position
8
Pump speed
r/min
250
250
250
Average injection quantity
mm3/st.
30
27
33
Max. variation between cylinders
%
0
-10
10
Fixing the rack
*
Injection quantity adjustment_04
Adjusting point
D
Rack position
5.4
Pump speed
r/min
750
750
750
Average injection quantity
mm3/st.
30
25
35
Fixing the rack
*
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)Idle sub spring setting: L1.
----------
K=7 L1=5.6-0.5mm
----------
----------
K=7 L1=5.6-0.5mm
----------
Speed control lever angle
F:Full speed
S:Stop
----------
----------
a=(23deg) b=32deg+-3deg
----------
----------
a=(23deg) b=32deg+-3deg
0000000901
F:Full load
I:Idle
S:Stop
----------
----------
a=5deg+-5deg b=31deg+-3deg c=7deg+-3deg
----------
----------
a=5deg+-5deg b=31deg+-3deg c=7deg+-3deg