Rating:
Information injection-pump assembly
BOSCH
F 019 Z20 085
f019z20085
ZEXEL
106671-9470
1066719470
Cross reference number
BOSCH
F 019 Z20 085
f019z20085
ZEXEL
106671-9470
1066719470
Zexel num
Bosch num
Firm num
Name
106671-9470
F 019 Z20 085
DPICO
INJECTION-PUMP ASSEMBLY
H100 Q
H100 Q
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 8-3-600
Outer diameter - inner diameter - length (mm) mm 8-3-600
Overflow valve
134424-1420
Overflow valve opening pressure
kPa
162
147
177
Overflow valve opening pressure
kgf/cm2
1.65
1.5
1.8
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-4-2-6-
3-5
Pre-stroke
mm
4
3.94
4
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-4 deg. 60 59.75 60.25
Cal 1-4 deg. 60 59.75 60.25
Difference between angles 2
Cyl.1-2 deg. 120 119.75 120.25
Cyl.1-2 deg. 120 119.75 120.25
Difference between angles 3
Cal 1-6 deg. 180 179.75 180.25
Cal 1-6 deg. 180 179.75 180.25
Difference between angles 4
Cal 1-3 deg. 240 239.75 240.25
Cal 1-3 deg. 240 239.75 240.25
Difference between angles 5
Cal 1-5 deg. 300 299.75 300.25
Cal 1-5 deg. 300 299.75 300.25
Injection quantity adjustment
Adjusting point
A
Rack position
9.7
Pump speed
r/min
700
700
700
Average injection quantity
mm3/st.
130
128
132
Max. variation between cylinders
%
0
-2
2
Basic
*
Fixing the lever
*
Boost pressure
kPa
53.3
53.3
Boost pressure
mmHg
400
400
Injection quantity adjustment_02
Adjusting point
C
Rack position
6.4+-0.5
Pump speed
r/min
260
260
260
Average injection quantity
mm3/st.
11
9
13
Max. variation between cylinders
%
0
-15
15
Fixing the rack
*
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Injection quantity adjustment_03
Adjusting point
G
Rack position
-
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
125
120
130
Fixing the lever
*
Boost pressure
kPa
53.3
53.3
Boost pressure
mmHg
400
400
Rack limit
*
Boost compensator adjustment
Pump speed
r/min
550
550
550
Rack position
R1(8.8)
Boost pressure
kPa
22.7
22.7
22.7
Boost pressure
mmHg
170
170
170
Boost compensator adjustment_02
Pump speed
r/min
550
550
550
Rack position
R1+0.45
Boost pressure
kPa
28.7
28
29.4
Boost pressure
mmHg
215
210
220
Boost compensator adjustment_03
Pump speed
r/min
550
550
550
Rack position
(9.7)
Boost pressure
kPa
40
40
40
Boost pressure
mmHg
300
300
300
Timer adjustment
Pump speed
r/min
1000--
Advance angle
deg.
0
0
0
Remarks
Start
Start
Timer adjustment_02
Pump speed
r/min
950
Advance angle
deg.
0.5
Timer adjustment_03
Pump speed
r/min
1150
Advance angle
deg.
2
1.5
2.5
Remarks
Finish
Finish
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Tolerance for racks not indicated: +-0.05mm.
(3)Microswitch not operating at delivery.
(3)Set idle at point K (N = N1, R = R1) and confirm that the injection quantity does not exceed Q1 at point J (N = N2).
(4)RACK LIMIT
(5)Boost compensator stroke: BCL
(6)Damper spring setting
(7)Rack difference between N = N3 and N = N4
(8)Boost compensator cancel stroke: BSL
----------
N1=300r/min R1=6.4mm N2=1150r/min Q1=3mm3/st BCL=(0.9)mm N3=1150r/min N4=700r/min BSL=2.2mm
----------
----------
N1=300r/min R1=6.4mm N2=1150r/min Q1=3mm3/st BCL=(0.9)mm N3=1150r/min N4=700r/min BSL=2.2mm
----------
Speed control lever angle
F:Full speed
----------
----------
a=(7deg)+-5deg
----------
----------
a=(7deg)+-5deg
0000000901
F:Full load
I:Idle
(1)Stopper bolt setting
(2)Use the hole at R = aa
----------
aa=65mm
----------
a=22deg+-5deg b=28.5deg+-3deg
----------
aa=65mm
----------
a=22deg+-5deg b=28.5deg+-3deg
Stop lever angle
N:Pump normal
S:Stop the pump.
(1)Use the pin at R = aa
----------
aa=30mm
----------
a=64deg+-5deg b=44deg+-5deg
----------
aa=30mm
----------
a=64deg+-5deg b=44deg+-5deg
Timing setting
(1)Pump vertical direction
(2)Coupling's key groove position at No 1 cylinder's beginning of injection
(3)-
(4)-
----------
----------
a=(50deg)
----------
----------
a=(50deg)
Have questions with 106671-9470?
Group cross 106671-9470 ZEXEL
Niigata-Urawa
Dpico
Komatsu
Mitsubishi-Heav
Dpico
106671-9470
F 019 Z20 085
INJECTION-PUMP ASSEMBLY
H100
H100