Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8130
Bosch type code   EFEP215A
Nozzle   105780-0050
Bosch type code   DN6TD119NP1T
Nozzle holder   105780-2090
Bosch type code   EFEP215
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   131424-4620
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   4.8 4.75 4.85
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.2
Pump speed r/min   700 700 700
Each cylinder's injection qty mm3/st.   251.2 244.9 257.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   F
Rack position   5+-0.5
Pump speed r/min   500 500 500
Each cylinder's injection qty mm3/st.   12.4 10.5 14.3
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.2)
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   251.2 250.2 252.2
Basic   *
Fixing the lever   *
Boost pressure kPa   58 58
Boost pressure mmHg   435 435
Injection quantity adjustment_04
Adjusting point   B
Rack position   R2(10.2)
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   254.5 252.5 256.5
Difference in delivery mm3/st.   9.2 9.2 9.2
Fixing the lever   *
Boost pressure kPa   58 58
Boost pressure mmHg   435 435
Injection quantity adjustment_05
Adjusting point   C
Rack position   5.7+-0.5
Pump speed r/min   225 225 225
Each cylinder's injection qty mm3/st.   20 17 23
Fixing the rack   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Remarks
(check)
 
Injection quantity adjustment_06
Adjusting point   D
Rack position   R3(8.3)
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   136.5 132.7 140.3
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Injection quantity adjustment_07
Adjusting point   E
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   151 131 171
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Boost compensator adjustment
Pump speed r/min   600 600 600
Rack position   R3(8.3)
Boost pressure kPa   6.7 6.7 6.7
Boost pressure mmHg   50 50 50
Boost compensator adjustment_02
Pump speed r/min   600 600 600
Rack position   8.9
Boost pressure kPa   12.7 12.7 12.7
Boost pressure mmHg   95 95 95
Boost compensator adjustment_03
Pump speed r/min   600 600 600
Rack position   9.9
Boost pressure kPa   24.7 23.4 26
Boost pressure mmHg   185 175 195
Boost compensator adjustment_04
Pump speed r/min   600 600 600
Rack position   R1(11.2)
Boost pressure kPa   44.7 44.7 44.7
Boost pressure mmHg   335 335 335

Test data Ex:

Governor adjustment

Test data 106671-7770
N:Pump speed R:Rack position (mm) (1)Boost compensator cancel stroke: BSL (2)RACK LIMIT: RAL (3)Boost compensator stroke (4)Damper spring setting: DL
----------
BSL=3mm RAL=11.5+-0.1mm DL=4.5-0.2mm
----------

Timer adjustment

Test data 106671-7770
(1)Adjusting range (2)Step response time (N): Speed of the pump (L): Load (theta) Advance angle (Srd1) Step response time 1 (Srd2) Step response time 2 1. Adjusting conditions for the variable timer (1)Adjust the clearance between the pickup and the protrusion to L.
----------
L=1-0.2mm N2=800r/min C2=(8deg) t1=2.5--sec. t2=2.5--sec.
----------
N1=1100++r/min P1=0kPa(0kgf/cm2) P2=392kPa(4kgf/cm2) C1=8+-0.3deg R01=0/4load R02=4/4load

Speed control lever angle

Test data 106671-7770
F:Full speed
----------

----------
a=17deg+-5deg

0000000901

Test data 106671-7770
F:Full load I:Idle (1)Use the hole at R = aa (2)Stopper bolt setting
----------
aa=46mm
----------
a=28deg+-5deg b=37deg+-3deg

Stop lever angle

Test data 106671-7770
N:Pump normal S:Stop the pump. (1)Rack position = aa (2)Stopper bolt setting (3)Rack position bb (4)Free (at shipping)
----------
aa=4.1-0.5mm bb=13.3mm
----------
a=26deg+-5deg b=(38deg) c=0deg+7deg-5deg

0000001501 RACK SENSOR

Test data 106671-7770
V1:Supply voltage V2f:Full side output voltage V2i:Idle side output voltage (A) Black (B) Yellow (C) Red (D) Trimmer (E): Shaft (F) Nut (G) Load lever 1. Load sensor adjustment (1)Connect as shown in the above diagram and apply supply voltage V1. (2)Hold the load lever (G) against the full side. (3)Turn the shaft so that the voltage between (A) and (B) is V2. (4)Hold the load lever (G) against the idle side. (5)Adjust (D) so that the voltage between (A) and (B) is V2i. (6)Repeat the above adjustments. (7)Tighten the nut (F) at the point satisfying the standards. (8)Hold the load lever against the full side stopper and the idle side stopper. (9)At this time, confirm that the full side output voltage is V2f and the idle side output voltage is V2i.
----------
V1= 5+-0.02V V2f=0.15+0.03V V2i=2.35-0.03V
----------

0000001601 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=325+-5r/min Ra=5.4mm
----------

Timing setting

Test data 106671-7770
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(7deg)




Have questions with 106671-7770?





Group cross 106671-7770 ZEXEL

Mitsubishi 

 
 
INJECTION-PUMP ASSEMBLY
6D22T2
 
ME056663 
INJECTION-PUMP ASSEMBLY
6D22T2
 
ME056664 
INJECTION-PUMP ASSEMBLY
6D22T2
 
 
INJECTION-PUMP ASSEMBLY
6D22T3
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 616 951 
ME056666 
INJECTION-PUMP ASSEMBLY
6D22T3
 
 
INJECTION-PUMP ASSEMBLY
6D22T3
9 400 616 952 
ME056667 
INJECTION-PUMP ASSEMBLY
6D22T3
 
ME056668 
INJECTION-PUMP ASSEMBLY
6D22T5
 
ME056688 
INJECTION-PUMP ASSEMBLY
6D22T3
 
ME050856 
INJECTION-PUMP ASSEMBLY
6D22T
106671-7770  

106671-7771 
 
 
INJECTION-PUMP ASSEMBLY
6D22T3
 
ME056719 
INJECTION-PUMP ASSEMBLY
6D22T3
 
 
INJECTION-PUMP ASSEMBLY
6D22T2
F 019 Z20 412 
ME056720 
INJECTION-PUMP ASSEMBLY
6D22T2
F 01G 09U 07L 
ME056721 
INJECTION-PUMP ASSEMBLY
6D22T2
Back to top