106671-6482 ZEXEL 9 400 612 540 BOSCH INJECTION-PUMP ASSEMBLY 9400612540 1066716482 1156033481


106671-6482 INJECTION-PUMP ASSEMBLY
Rating:
20
Buy INJECTION-PUMP ASSEMBLY 106671-6482 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 612 540 9400612540
ZEXEL 106671-6482 1066716482
ISUZU 1156033481 1156033481

Service parts 106671-6482 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 106067-6390
3. GOVERNOR 105960-0331
4. SUPPLY PUMP 105237-5550
5. AUTOM. ADVANCE MECHANIS 105681-6040
6. COUPLING PLATE 105664-2041
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105110-8170
11. Nozzle and Holder 1-15300-393-0
12. Open Pre:MPa(Kqf/cm2) 17.7{180}/22.1{225}
13. NOZZLE-HOLDER 105041-4341
14. NOZZLE
15. NOZZLE SET 105019-2701

Include in #1:

106671-6482 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 612 540 9400612540
ZEXEL 106671-6482 1066716482
ISUZU 1156033481 1156033481


Zexel num
Bosch num
Firm num
Name
106671-6482 
106671-6483 
9 400 612 540 
1156033481  ISUZU
INJECTION-PUMP ASSEMBLY
6SD1-XQB * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   134424-4320
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
RED4 control unit part number   407915-0 590
RED4 rack sensor specifications mm   19
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.9 3.87 3.93
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.75 60.25
Difference between angles 2
Cal 1-3
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cyl.1-2
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-4
deg.   300 299.75 300.25
Injection quantity adjustment
Rack position   (15.4)
PWM %   74.8
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   176.5 174.5 178.5
Max. variation between cylinders %   0 -3 3
Basic   *
Injection quantity adjustment_02
Rack position   (8.7)
PWM %   37.1+-2. 8
Pump speed r/min   450 450 450
Average injection quantity mm3/st.   13.5 10.3 16.7
Max. variation between cylinders %   0 -13 13
Governor adjustment
Pump speed r/min   1100++
Advance angle deg.   0 0 0
Remarks
Do not advance until starting N = 1100.
 
Governor adjustment_02
Pump speed r/min   -
Advance angle deg.   0.5 0.5 0.5
Remarks
Measure the actual speed, stop
 

Test data Ex:

Speed control lever angle

Test data 106671-6482
N:Pump normal S:Stop the pump. (1)Rack position = aa (2)Rack position bb
----------
aa=1mm bb=20mm
----------
a=20deg+-5deg b=37deg+-5deg

0000000901

Test data 106671-6482
(1)Pump vertical direction (2)Positions of coupling's threaded installation holes at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=7deg
----------
a=(50deg)

Stop lever angle

Test data 106671-6482
(PWM) Pulse width modulation (%) (R) Rack position (mm) Rack sensor output characteristics 1. Rack limit adjustment (1)Measure the rack position R2 for PWM a2%. (2)Confirm that it is within the range R2 = 15+-1 mm. (3)Measure the rack position R1 at PWM a %. (4)Confirm that it is within the range R2 - R1 = 10+-0.1 mm. 2. Check the limp home operation. (1)Move the switch box's limp home switch to the limp home side. (2)Confirm rack position L1 (mm ) and L2 (mm) for PWM in the above table. 3. Check the pull down operation. (1)Confirm that the rack position is 19 mm at PWM B%. (2)In the conditions described in the above table, move the switch box's pull down switch to the pull down side and confirm that the rack position momentarily becomes 1 mm or less.
----------
a1=16.25% a2=72.5% L1=1--mm L2=19++mm A=5 % B=95%
----------




Have questions with 106671-6482?





Group cross 106671-6482 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

 
1156033480 
INJECTION-PUMP ASSEMBLY
6SD1-TC
106671-6482  

106671-6483 
9 400 612 540 
1156033481 
INJECTION-PUMP ASSEMBLY
6SD1-XQB
9 400 612 376 
1156033482 
INJECTION-PUMP ASSEMBLY
6SD1-XQB
9 400 612 664 
1156033483 
INJECTION-PUMP ASSEMBLY
6SD1-XQB
Back to top