Rating:
Information injection-pump assembly
ZEXEL
106671-2370
1066712370
Cross reference number
ZEXEL
106671-2370
1066712370
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8130
Bosch type code
EFEP215A
Nozzle
105780-0050
Bosch type code
DN6TD119NP1T
Nozzle holder
105780-2090
Bosch type code
EFEP215
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 8-3-600
Outer diameter - inner diameter - length (mm) mm 8-3-600
Overflow valve
131424-1520
Overflow valve opening pressure
kPa
157
123
191
Overflow valve opening pressure
kgf/cm2
1.6
1.25
1.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left L
Left L
Injection order
1-5-3-6-
2-4
Pre-stroke
mm
2.7
2.65
2.75
Rack position
Point A R=A
Point A R=A
Beginning of injection position
Governor side NO.1
Governor side NO.1
Difference between angles 1
Cal 1-5 deg. 60 59.5 60.5
Cal 1-5 deg. 60 59.5 60.5
Difference between angles 2
Cal 1-3 deg. 120 119.5 120.5
Cal 1-3 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cyl.1-2 deg. 240 239.5 240.5
Cyl.1-2 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-4 deg. 300 299.5 300.5
Cal 1-4 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
A
Rack position
15
Pump speed
r/min
750
750
750
Average injection quantity
mm3/st.
390
381
399
Max. variation between cylinders
%
0
-3
3
Basic
*
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
B
Rack position
15+-0.5
Pump speed
r/min
450
450
450
Average injection quantity
mm3/st.
367
357
377
Max. variation between cylinders
%
0
-5
5
Fixing the lever
*
Injection quantity adjustment_03
Adjusting point
C
Rack position
5.9+-0.5
Pump speed
r/min
250
250
250
Average injection quantity
mm3/st.
35.5
32.5
38.5
Max. variation between cylinders
%
0
-10
10
Fixing the rack
*
Injection quantity adjustment_04
Adjusting point
D
Rack position
4.3+-0.5
Pump speed
r/min
750
750
750
Average injection quantity
mm3/st.
35.4
30.4
40.4
Fixing the rack
*
Injection quantity adjustment_05
Adjusting point
E
Rack position
21+-0.5
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
295
295
320
Fixing the lever
*
Timer adjustment
Pump speed
r/min
400
Advance angle
deg.
0.5
Timer adjustment_02
Pump speed
r/min
700
Advance angle
deg.
1.2
0.7
1.7
Timer adjustment_03
Pump speed
r/min
-
Advance angle
deg.
4
4
4
Remarks
Measure the actual speed, stop
Measure the actual speed, stop
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)Tolerance for racks not indicated: +-0.05mm.
(3)Idle sub spring setting: L1.
----------
K=10 L1=4.3-0.5mm
----------
----------
K=10 L1=4.3-0.5mm
----------
Speed control lever angle
F:Full speed
S:Stop
----------
----------
a=23deg+-5deg b=32deg+-3deg
----------
----------
a=23deg+-5deg b=32deg+-3deg
0000000901
F:Full load
I:Idle
S:Stop
(1)Contacts inner boss.
(2)Contacts outer stopper.
----------
----------
a=5deg+-5deg b=(42deg) c=31deg+-3deg d=12.5deg+-3deg
----------
----------
a=5deg+-5deg b=(42deg) c=31deg+-3deg d=12.5deg+-3deg
Timing setting
(1)Pump vertical direction
(2)Coupling's key groove position at No 1 cylinder's beginning of injection
(3)-
(4)-
----------
----------
a=(20deg)
----------
----------
a=(20deg)