106671-1368 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1066711368 1156021402


106671-1368 INJECTION-PUMP ASSEMBLY
Rating:
11
Buy INJECTION-PUMP ASSEMBLY 106671-1368 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 106671-1368 1066711368
ISUZU 1156021402 1156021402

Cross reference number

ZEXEL 106671-1368 1066711368
ISUZU 1156021402 1156021402


Zexel num
Bosch num
Firm num
Name
106671-1368 
106671-1367 
 
1156021402  ISUZU
INJECTION-PUMP ASSEMBLY
6SD1X *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.7 3.67 3.73
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.75 60.25
Difference between angles 2
Cal 1-3
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cyl.1-2
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-4
deg.   300 299.75 300.25
Injection quantity adjustment
Adjusting point   A
Rack position   8.5
Pump speed r/min   650 650 650
Average injection quantity mm3/st.   131.5 129.5 133.5
Max. variation between cylinders %   0 -3 3
Basic   *
Fixing the lever   *
Boost pressure kPa   30.7 30.7
Boost pressure mmHg   230 230
Injection quantity adjustment_02
Adjusting point   B
Rack position   7.7
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   119.8 117.8 121.8
Max. variation between cylinders %   0 -4 4
Fixing the lever   *
Boost pressure kPa   30.7 30.7
Boost pressure mmHg   230 230
Injection quantity adjustment_03
Adjusting point   C
Rack position   5.4+-0.5
Pump speed r/min   250 250 250
Average injection quantity mm3/st.   8.2 5 11.4
Max. variation between cylinders %   0 -13 13
Fixing the rack   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Injection quantity adjustment_04
Adjusting point   D
Rack position   -
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   85 85
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Boost compensator adjustment
Pump speed r/min   650 650 650
Rack position   7
Boost pressure kPa   3.3 3.3 5.3
Boost pressure mmHg   25 25 40
Boost compensator adjustment_02
Pump speed r/min   650 650 650
Rack position   8.5
Boost pressure kPa   17.3 17.3 17.3
Boost pressure mmHg   130 130 130

Test data Ex:

Governor adjustment

Test data 106671-1368
N:Pump speed R:Rack position (mm) (1)Excess fuel setting for starting: SXL (2)Boost compensator stroke: BCL (3)Damper spring setting: DL
----------
SXL=8.6+0.2mm BCL=1.5+-0.1mm DL=4.4-0.5mm
----------

Timer adjustment

Test data 106671-1368
(1)Adjusting range (2)Step response time (N): Speed of the pump (L): Load (theta) Advance angle (Srd1) Step response time 1 (Srd2) Step response time 2 1. Adjusting conditions for the variable timer (1)Adjust the clearance between the pickup and the protrusion to L.
----------
L=1-0.2mm N2=800r/min C2=(5.5)deg t1=2--sec. t2=2--sec.
----------
N1=800++r/min P1=0kPa(0kgf/cm2) P2=392kPa(4kgf/cm2) C1=5.5+-0.3deg R01=0/4load R02=4/4load

Speed control lever angle

Test data 106671-1368
F:Full speed
----------

----------
a=8deg+-5deg

0000000901

Test data 106671-1368
F:Full load I:Idle (1)Stopper bolt setting (2)Use the hole at R = aa
----------
aa=35mm
----------
a=15deg+-5deg b=35deg+-3deg

Stop lever angle

Test data 106671-1368
N:Pump normal S:Stop the pump.
----------

----------
a=37deg+-5deg b=73deg+-5deg

0000001501 RACK SENSOR

Test data 106671-1368
V1:Supply voltage V2f:Full side output voltage V2i:Idle side output voltage (A) Black (B) Yellow (C) Red (D) Trimmer (E): Shaft (F) Nut (G) Load lever 1. Load sensor adjustment (1)Connect as shown in the above diagram and apply supply voltage V1. (2)Hold the load lever (G) against the full side. (3)Turn the shaft so that the voltage between (A) and (B) is V2. (4)Hold the load lever (G) against the idle side. (5)Adjust (D) so that the voltage between (A) and (B) is V2i. (6)Repeat the above adjustments. (7)Tighten the nut (F) at the point satisfying the standards. (8)Hold the load lever against the full side stopper and the idle side stopper. (9)At this time, confirm that the full side output voltage is V2f and the idle side output voltage is V2i.
----------
V1= 5+-0.02V V2f=0.15+0.03V V2i=2.35-0.03V
----------

Timing setting

Test data 106671-1368
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(40deg)




Have questions with 106671-1368?





Group cross 106671-1368 ZEXEL

Isuzu 

 
1156021403 
INJECTION-PUMP ASSEMBLY
6SD1-X
 
1156021404 
INJECTION-PUMP ASSEMBLY
6SD1-X
 
1156021405 
INJECTION-PUMP ASSEMBLY
6SD1-TC1
 
1156021406 
INJECTION-PUMP ASSEMBLY
6SD1-TC1
 
1156021407 
INJECTION-PUMP ASSEMBLY
6SD1-TC1
 
1156019516 
INJECTION-PUMP ASSEMBLY
6SD1X
 
1156021400 
INJECTION-PUMP ASSEMBLY
6SD1X
 
1156021401 
INJECTION-PUMP ASSEMBLY
6SD1X
106671-1368  

106671-1367 
 
1156021402 
INJECTION-PUMP ASSEMBLY
6SD1X
Back to top