106651-4130 ZEXEL F 019 Z20 065 BOSCH INJECTION-PUMP ASSEMBLY f019z20065 1066514130


106651-4130 INJECTION-PUMP ASSEMBLY
Rating:
26
Buy INJECTION-PUMP ASSEMBLY 106651-4130 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH F 019 Z20 065 f019z20065
ZEXEL 106651-4130 1066514130

Cross reference number

BOSCH F 019 Z20 065 f019z20065
ZEXEL 106651-4130 1066514130


Zexel num
Bosch num
Firm num
Name
106651-4130 
F 019 Z20 065 
  DPICO
INJECTION-PUMP ASSEMBLY
6D22T Q

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   8-3-600
Overflow valve   131424-4420
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   5.1 5.05 5.15
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   10.4
Pump speed r/min   700 700 700
Each cylinder's injection qty mm3/st.   107 104.3 109.7
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   C
Rack position   6.7+-0.5
Pump speed r/min   225 225 225
Each cylinder's injection qty mm3/st.   25.5 21.7 29.3
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(10.4)
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   107 106 108
Basic   *
Fixing the lever   *
Boost pressure kPa   34 34
Boost pressure mmHg   255 255
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1(10.4)
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   109 103 115
Difference in delivery mm3/st.   8 8 8
Fixing the lever   *
Boost pressure kPa   34 34
Boost pressure mmHg   255 255
Injection quantity adjustment_05
Adjusting point   E
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   80 40 120
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Boost compensator adjustment
Pump speed r/min   600 600 600
Rack position   R2-0.5
Boost pressure kPa   17.3 16 18.6
Boost pressure mmHg   130 120 140
Boost compensator adjustment_02
Pump speed r/min   600 600 600
Rack position   R2(R1(10 .4))
Boost pressure kPa   24 20.7 27.3
Boost pressure mmHg   180 155 205
Timer adjustment
Pump speed r/min   -
Advance angle deg.   1.5 1 2
Load   0/4
Remarks
Measure speed (beginning of operation).
 
Timer adjustment_02
Pump speed r/min   -
Advance angle deg.   0 0 0
Load   0/4
Remarks
Measure the actual speed.
 
Timer adjustment_03
Pump speed r/min   -
Advance angle deg.   0.5
Load   4/4
Remarks
Measure the actual speed.
 
Timer adjustment_04
Pump speed r/min   -
Advance angle deg.   2.5 2 3
Load   4/4
Remarks
Measure the actual speed, stop
 

Test data Ex:

Governor adjustment

Test data 106651-4130
N:Pump speed R:Rack position (mm) (1)Tolerance for racks not indicated: +-0.05mm. (2)Boost compensator stroke: BCL (3)Damper spring setting: DL
----------
BCL=0.5+-0.1mm DL=6.7-0.2mm
----------

Speed control lever angle

Test data 106651-4130
F:Full speed
----------

----------
a=(6deg)+-5deg

0000000901

Test data 106651-4130
F:Full load I:Idle (1)Stopper bolt setting
----------

----------
a=21deg+-5deg b=28.5deg+-3deg

Stop lever angle

Test data 106651-4130
N:Engine manufacturer's normal use S:Stop the pump. (1)Rack position = aa (2)Stopper bolt setting (3)Rack position bb (4)Free (at delivery)
----------
aa=4.9-0.5mm bb=14mm
----------
a=25.5deg+-5deg b=(35.5deg) c=0deg+7deg-5deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=325r/min Ra=6.4+-0.1mm
----------

Timing setting

Test data 106651-4130
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=15deg
----------
a=(4deg)




Have questions with 106651-4130?





Group cross 106651-4130 ZEXEL

Dpico 

 
 
INJECTION-PUMP ASSEMBLY
6D22T
 
 
INJECTION-PUMP ASSEMBLY
6D22T
F 019 Z20 063 
 
INJECTION-PUMP ASSEMBLY
6D22T
F 019 Z20 064 
 
INJECTION-PUMP ASSEMBLY
6D22T
106651-4130  
F 019 Z20 065 
 
INJECTION-PUMP ASSEMBLY
6D22T
Back to top