104760-7000 ZEXEL 9 460 614 753 BOSCH INJECTION-PUMP ASSEMBLY 9460614753 1047607000 16700wj206


104760-7000 INJECTION-PUMP ASSEMBLY
Rating:
22
Buy INJECTION-PUMP ASSEMBLY 104760-7000 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 460 614 753 9460614753
ZEXEL 104760-7000 1047607000
NISSAN-DIESEL 16700WJ206 16700wj206

Cross reference number

BOSCH 9 460 614 753 9460614753
ZEXEL 104760-7000 1047607000
NISSAN-DIESEL 16700WJ206 16700wj206


Zexel num
Bosch num
Firm num
Name
104760-7000 
9 460 614 753 
16700WJ206  NISSAN-DIESEL
INJECTION-PUMP ASSEMBLY
TD42 K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105780-0060
Bosch type code   NP-DN0SD1510
Nozzle holder   105780-2150
Opening pressure MPa   13 13 13.3
Opening pressure kgf/cm2   133 133 136
Injection pipe   157805-7320
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-450
Joint assembly   157641-4720
Tube assembly   157641-4020
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   46.9 46.4 47.4
Difference in delivery mm3/st.   3.5
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_02
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   47 44.5 49.5
Oil temperature degC   50 48 52
Injection timing adjustment_03
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   46.9 45.9 47.9
Difference in delivery mm3/st.   4
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_04
Pump speed r/min   2000 2000 2000
Average injection quantity mm3/st.   42.5 40 45
Oil temperature degC   50 48 52
Injection quantity adjustment
Pump speed r/min   2300 2300 2300
Average injection quantity mm3/st.   17.8 15.8 19.8
Difference in delivery mm3/st.   5
Basic   *
Oil temperature degC   52 50 54
Injection quantity adjustment_02
Pump speed r/min   2500 2500 2500
Average injection quantity mm3/st.   5
Oil temperature degC   55 52 58
Injection quantity adjustment_03
Pump speed r/min   2200 2200 2200
Average injection quantity mm3/st.   32.2 27.7 36.7
Oil temperature degC   52 50 54
Injection quantity adjustment_04
Pump speed r/min   2300 2300 2300
Average injection quantity mm3/st.   17.8 15.3 20.3
Basic   *
Oil temperature degC   52 50 54
Governor adjustment
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   10.1 8.1 12.1
Difference in delivery mm3/st.   2
Basic   *
Oil temperature degC   48 46 50
Governor adjustment_02
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   10.1 7.6 12.6
Difference in delivery mm3/st.   2.5
Basic   *
Oil temperature degC   48 46 50
Timer adjustment
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   60 50 80
Basic   *
Oil temperature degC   48 46 50
Remarks
Full
 
Timer adjustment_02
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   60 50 80
Oil temperature degC   48 46 50
Remarks
Full
 
Speed control lever angle
Pump speed r/min   250 250 250
Average injection quantity mm3/st.   5
Oil temperature degC   48 46 50
Remarks
Magnet OFF at full-load position
 
Speed control lever angle_02
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   0 0 0
Oil temperature degC   48 46 50
Remarks
Magnet OFF at idling position
 
0000000901
Pump speed r/min   1000 1000 1000
Overflow quantity cm3/min   390 260 520
Oil temperature degC   50 48 52
Stop lever angle
Pump speed r/min   1000 1000 1000
Pressure kPa   422 393 451
Pressure kgf/cm2   4.3 4 4.6
Basic   *
Oil temperature degC   50 48 52
Stop lever angle_02
Pump speed r/min   1000 1000 1000
Pressure kPa   422 383 461
Pressure kgf/cm2   4.3 3.9 4.7
Basic   *
Oil temperature degC   50 48 52
Stop lever angle_03
Pump speed r/min   1800 1800 1800
Pressure kPa   686 647 725
Pressure kgf/cm2   7 6.6 7.4
Oil temperature degC   50 48 52
0000001101
Pump speed r/min   1000 1000 1000
Timer stroke mm   2.9 2.7 3.1
Basic   *
Oil temperature degC   50 48 52
_02
Pump speed r/min   650 650 650
Timer stroke mm   1.2 0.7 1.7
Oil temperature degC   50 48 52
_03
Pump speed r/min   1000 1000 1000
Timer stroke mm   2.9 2.6 3.2
Basic   *
Oil temperature degC   50 48 52
_04
Pump speed r/min   1800 1800 1800
Timer stroke mm   6.6 6.1 7.1
Oil temperature degC   50 48 52
_05
Pump speed r/min   2150 2150 2150
Timer stroke mm   8.2 7.7 8.6
Oil temperature degC   52 50 54
0000001201
Max. applied voltage V   16 16 16
Test voltage V   25 24 26
0000001401
Pump speed r/min   1200 1200 1200
Average injection quantity mm3/st.   32 31.5 32.5
Timer stroke TA mm   3.4 3.2 3.6
Timer stroke variation dT mm   0.5 0.5 0.5
Basic   *
Oil temperature degC   50 48 52
_02
Pump speed r/min   1200 1200 1200
Average injection quantity mm3/st.   32 31 33
Timer stroke TA mm   3.4 3.1 3.7
Timer stroke variation dT mm   0.5 0.5 0.5
Basic   *
Oil temperature degC   50 48 52
_03
Pump speed r/min   1200 1200 1200
Average injection quantity mm3/st.   23 20.5 25.5
Timer stroke TA mm   2.9 2.3 3.5
Timer stroke variation dT mm   1 1 1
Oil temperature degC   50 48 52
Timing setting
K dimension mm   3.3 3.2 3.4
KF dimension mm   6.76 6.66 6.86
MS dimension mm   1 0.9 1.1
Control lever angle alpha deg.   55.5 51.5 59.5
Control lever angle beta deg.   40 35 45

Test data Ex:

0000001801 POTENTIOMETER ADJUSTMENT

Test data 104760-7000
Adjustment of the potentiometer In the following condition, change the installation position of the potentiometer to adjust the output voltage to within the specified values. Measure the injection quantity at control lever position a (shim thickness = approximately L mm) at N = N1 r/min, determine the voltage using the formula, and adjust the potentiometer. A:Performance standards C:Position of the control lever N:Pump speed Vo:Output voltage E:Conversion formula G:Idling H:Full speed K:Applied voltage X:Injection quantity (cm3/1,000st) Y:Voltage (V) R:At target value Q1cm3/1,000 st, set voltage at V3 (V). M:The switch voltage specification is the value when the idle lever position is V6. B:Conversion point B1:ON-->OFF B2:OFF-->ON D:Lever opening (from idle)
----------
N1=1,200r/min a=16.9deg L=11.1+-0.05mm Q1=20.0cm3/1,000st V3=4.32V V6=0V
----------
V1=1.51+-0.60V V2=8.01+-0.75V V4=0.9+-0.8V V5=3.3+-0.8V K=10V D1=5.4+-5deg D2=20.0+-5deg J:V=0.0397X+3.516




Have questions with 104760-7000?





Group cross 104760-7000 ZEXEL

Nissan-Diesel 

104760-7000  
9 460 614 753 
16700WJ206 
INJECTION-PUMP ASSEMBLY
TD42
9 460 614 192 
16700WK000 
INJECTION-PUMP ASSEMBLY
TD42
9 460 614 822 
16700WK001 
INJECTION-PUMP ASSEMBLY
TD42
9 460 614 821 
16700WK002 
INJECTION-PUMP ASSEMBLY
TD42
9 460 614 863 
 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

F 01G 09W 00Z 
16700WJ105 
INJECTION-PUMP ASSEMBLY
TD42T
9 460 615 094 
167001Y60A 
INJECTION-PUMP ASSEMBLY
TD42
F 01G 09W 0DV 
1670028D0A 
INJECTION-PUMP ASSEMBLY
TD42T
F 01G 09W 0C8 
16700GL00A 
INJECTION-PUMP ASSEMBLY
TD42
F 01G 09W 0E8 
16700GL00B 
INJECTION-PUMP ASSEMBLY
TD42
F 01G 09W 0FP 
 
INJECTION-PUMP ASSEMBLY
TD42T

Nissan-Diesel 

F 01G 09W 0FP 
1670016D0A 
INJECTION-PUMP ASSEMBLY
TD42T
Back to top