104760-4990 ZEXEL 9 460 614 752 BOSCH INJECTION-PUMP ASSEMBLY 9460614752 1047604990 16700wj205


104760-4990 INJECTION-PUMP ASSEMBLY
Rating:
21
Buy INJECTION-PUMP ASSEMBLY 104760-4990 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 460 614 752 9460614752
ZEXEL 104760-4990 1047604990
NISSAN-DIESEL 16700WJ205 16700wj205

Cross reference number

BOSCH 9 460 614 752 9460614752
ZEXEL 104760-4990 1047604990
NISSAN-DIESEL 16700WJ205 16700wj205


Zexel num
Bosch num
Firm num
Name
104760-4990 
9 460 614 752 
16700WJ205  NISSAN-DIESEL
INJECTION-PUMP ASSEMBLY
TD42 K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105780-0060
Bosch type code   NP-DN0SD1510
Nozzle holder   105780-2150
Opening pressure MPa   13 13 13.3
Opening pressure kgf/cm2   133 133 136
Injection pipe   157805-7320
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-450
Joint assembly   157641-4720
Tube assembly   157641-4020
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   46.9 46.4 47.4
Difference in delivery mm3/st.   3.5
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_02
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   47 44.5 49.5
Oil temperature degC   50 48 52
Injection timing adjustment_03
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   46.9 45.9 47.9
Difference in delivery mm3/st.   4
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_04
Pump speed r/min   2000 2000 2000
Average injection quantity mm3/st.   42.5 40 45
Oil temperature degC   50 48 52
Injection quantity adjustment
Pump speed r/min   2300 2300 2300
Average injection quantity mm3/st.   17.8 15.8 19.8
Difference in delivery mm3/st.   5
Basic   *
Oil temperature degC   52 50 54
Injection quantity adjustment_02
Pump speed r/min   2500 2500 2500
Average injection quantity mm3/st.   5
Oil temperature degC   55 52 58
Injection quantity adjustment_03
Pump speed r/min   2200 2200 2200
Average injection quantity mm3/st.   32.2 27.7 36.7
Oil temperature degC   52 50 54
Injection quantity adjustment_04
Pump speed r/min   2300 2300 2300
Average injection quantity mm3/st.   17.8 15.3 20.3
Basic   *
Oil temperature degC   52 50 54
Governor adjustment
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   10.1 8.1 12.1
Difference in delivery mm3/st.   2
Basic   *
Oil temperature degC   48 46 50
Governor adjustment_02
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   10.1 7.6 12.6
Difference in delivery mm3/st.   2.5
Basic   *
Oil temperature degC   48 46 50
Timer adjustment
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   60 50 80
Basic   *
Oil temperature degC   48 46 50
Remarks
Full
 
Timer adjustment_02
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   60 50 80
Oil temperature degC   48 46 50
Remarks
Full
 
Speed control lever angle
Pump speed r/min   250 250 250
Average injection quantity mm3/st.   5
Oil temperature degC   48 46 50
Remarks
Magnet OFF at full-load position
 
Speed control lever angle_02
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   0 0 0
Oil temperature degC   48 46 50
Remarks
Magnet OFF at idling position
 
0000000901
Pump speed r/min   1000 1000 1000
Overflow quantity cm3/min   450 320 580
Oil temperature degC   50 48 52
Stop lever angle
Pump speed r/min   1000 1000 1000
Pressure kPa   422 393 451
Pressure kgf/cm2   4.3 4 4.6
Basic   *
Oil temperature degC   50 48 52
Stop lever angle_02
Pump speed r/min   1000 1000 1000
Pressure kPa   422 383 461
Pressure kgf/cm2   4.3 3.9 4.7
Basic   *
Oil temperature degC   50 48 52
Stop lever angle_03
Pump speed r/min   1800 1800 1800
Pressure kPa   686 647 725
Pressure kgf/cm2   7 6.6 7.4
Oil temperature degC   50 48 52
0000001101
Pump speed r/min   1000 1000 1000
Timer stroke mm   2.9 2.7 3.1
Basic   *
Oil temperature degC   50 48 52
_02
Pump speed r/min   650 650 650
Timer stroke mm   1.2 0.7 1.7
Oil temperature degC   50 48 52
_03
Pump speed r/min   1000 1000 1000
Timer stroke mm   2.9 2.6 3.2
Basic   *
Oil temperature degC   50 48 52
_04
Pump speed r/min   1800 1800 1800
Timer stroke mm   6.6 6.1 7.1
Oil temperature degC   50 48 52
_05
Pump speed r/min   2150 2150 2150
Timer stroke mm   8.2 7.7 8.6
Oil temperature degC   52 50 54
0000001201
Max. applied voltage V   16 16 16
Test voltage V   25 24 26
0000001401
Pump speed r/min   1200 1200 1200
Average injection quantity mm3/st.   32 31.5 32.5
Timer stroke TA mm   3.4 3.2 3.6
Timer stroke variation dT mm   0.5 0.5 0.5
Basic   *
Oil temperature degC   50 48 52
_02
Pump speed r/min   1200 1200 1200
Average injection quantity mm3/st.   32 31 33
Timer stroke TA mm   3.4 3.1 3.7
Timer stroke variation dT mm   0.5 0.5 0.5
Basic   *
Oil temperature degC   50 48 52
_03
Pump speed r/min   1200 1200 1200
Average injection quantity mm3/st.   23 20.5 25.5
Timer stroke TA mm   2.9 2.3 3.5
Timer stroke variation dT mm   1 1 1
Oil temperature degC   50 48 52
Timing setting
K dimension mm   3.3 3.2 3.4
KF dimension mm   6.76 6.66 6.86
MS dimension mm   1 0.9 1.1
Control lever angle alpha deg.   55.5 51.5 59.5
Control lever angle beta deg.   40 35 45

Test data Ex:

0000001801 POTENTIOMETER ADJUSTMENT

Test data 104760-4990
Adjustment of the potentiometer In the following condition, change the installation position of the potentiometer to adjust the output voltage to within the specified values. Measure the injection quantity at control lever position a (shim thickness = approximately L mm) at N = N1 r/min, determine the voltage using the formula, and adjust the potentiometer. A:Performance standards C:Position of the control lever N:Pump speed Vo:Output voltage E:Conversion formula G:Idling H:Full speed K:Applied voltage X:Injection quantity (cm3/1,000st) Y:Voltage (V) M:Connecting diagram for the potentiometer O:Output P:Output when (2) and (3) connected. R:At target value Q1cm3/1,000 st, set voltage at V3 (V).
----------
N1=1200r/min a=16.9deg L=11.1+-0.05mm Q1=20.0cm3/1,000st V3=4.32V
----------
V1=1.51+-0.60V V2=8.01+-0.75V K=10V J:V=0.0397X+3.516




Have questions with 104760-4990?





Group cross 104760-4990 ZEXEL

Nissan-Diesel 

9 460 613 431 
16700WJ400 
INJECTION-PUMP ASSEMBLY
TD42
9 460 613 440 
16700WJ500 
INJECTION-PUMP ASSEMBLY
TD42
9 460 613 468 
16700WJ501 
INJECTION-PUMP ASSEMBLY
TD42
9 460 613 511 
16700WJ202 
INJECTION-PUMP ASSEMBLY
TD42
9 460 613 978 
16700WJ203 
INJECTION-PUMP ASSEMBLY
TD42
9 460 613 533 
 
INJECTION-PUMP ASSEMBLY
TD42

Nissan-Diesel 

9 460 614 074 
16700WJ204 
INJECTION-PUMP ASSEMBLY
TD42

Nissan 

9 460 613 877 
16700VB506 
INJECTION-PUMP ASSEMBLY
TD42

Nissan-Diesel 

9 460 613 877 
16700VB506 
INJECTION-PUMP ASSEMBLY
TD42

Nissan 

9 460 613 948 
16700VB507 
INJECTION-PUMP ASSEMBLY
TD42

Nissan-Diesel 

9 460 613 948 
16700VB507 
INJECTION-PUMP ASSEMBLY
TD42
9 460 614 751 
16700NA000 
INJECTION-PUMP ASSEMBLY
TD42
104760-4990  
9 460 614 752 
16700WJ205 
INJECTION-PUMP ASSEMBLY
TD42
Back to top