104760-2511 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1047602511


104760-2511 INJECTION-PUMP ASSEMBLY
Rating:
35
Buy INJECTION-PUMP ASSEMBLY 104760-2511 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 104760-2511 1047602511

Cross reference number

ZEXEL 104760-2511 1047602511


Zexel num
Bosch num
Firm num
Name
104760-2511 
 
   
INJECTION-PUMP ASSEMBLY

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105780-0060
Bosch type code   NP-DN0SD1510
Nozzle holder   105780-2150
Opening pressure MPa   13 13 13.3
Opening pressure kgf/cm2   133 133 136
Injection pipe   157805-7320
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-450
Joint assembly   157641-4720
Tube assembly   157641-4020
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Right
  R
(Solenoid timer adjustment condition)
ON
  ON
Injection timing adjustment
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   31 30.6 31.4
Difference in delivery mm3/st.   2
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_02
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   30.9 28.9 32.9
Oil temperature degC   50 48 52
Injection timing adjustment_03
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   31 30 32
Difference in delivery mm3/st.   2.5
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_04
Pump speed r/min   1200 1200 1200
Average injection quantity mm3/st.   30.9 28.9 32.9
Oil temperature degC   50 48 52
Injection timing adjustment_05
Pump speed r/min   1800 1800 1800
Average injection quantity mm3/st.   32 29.5 34.5
Oil temperature degC   50 48 52
Injection timing adjustment_06
Pump speed r/min   2300 2300 2300
Average injection quantity mm3/st.   32.9 29.9 35.9
Oil temperature degC   52 50 54
Injection timing adjustment_07
Pump speed r/min   2500 2500 2500
Average injection quantity mm3/st.   32.9 29.4 36.4
Oil temperature degC   55 52 58
Injection quantity adjustment
Pump speed r/min   2600 2600 2600
Average injection quantity mm3/st.   27 25 29
Difference in delivery mm3/st.   4.5
Basic   *
Oil temperature degC   55 52 58
Injection quantity adjustment_02
Pump speed r/min   2600 2600 2600
Average injection quantity mm3/st.   27 24.5 29.5
Difference in delivery mm3/st.   5
Basic   *
Oil temperature degC   55 52 58
Injection quantity adjustment_03
Pump speed r/min   2800 2800 2800
Average injection quantity mm3/st.   6.5
Oil temperature degC   55 52 58
Governor adjustment
Pump speed r/min   290 290 290
Average injection quantity mm3/st.   9 8 10
Difference in delivery mm3/st.   1.1
Basic   *
Oil temperature degC   48 46 50
Governor adjustment_02
Pump speed r/min   290 290 290
Average injection quantity mm3/st.   9 7 11
Difference in delivery mm3/st.   1.8
Basic   *
Oil temperature degC   48 46 50
Timer adjustment
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   40 40
Basic   *
Oil temperature degC   48 46 50
Remarks
Full
 
Timer adjustment_02
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   40 40
Oil temperature degC   48 46 50
Speed control lever angle
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   0 0 0
Oil temperature degC   50 48 52
Remarks
Magnet OFF at full-load position
 
Speed control lever angle_02
Pump speed r/min   290 290 290
Average injection quantity mm3/st.   4
Oil temperature degC   48 46 50
Remarks
Magnet OFF at idling position
 
0000000901
Pump speed r/min   900 900 900
Overflow quantity with S/T ON cm3/min   465 335 595
Oil temperature degC   50 48 52
Stop lever angle
Pump speed r/min   900 900 900
Pressure with S/T ON kPa   373 344 402
Pressure with S/T ON kgf/cm2   3.8 3.5 4.1
Pressure with S/T OFF kPa   304 255 353
Pressure with S/T OFF kgf/cm2   3.1 2.6 3.6
Basic   *
Oil temperature degC   50 48 52
Remarks
ON
 
Stop lever angle_02
Pump speed r/min   900 900 900
Pressure kPa   372.5 333 412
Pressure kgf/cm2   3.8 3.4 4.2
Basic   *
Oil temperature degC   50 48 52
Stop lever angle_03
Pump speed r/min   1800 1800 1800
Pressure kPa   559 520 598
Pressure kgf/cm2   5.7 5.3 6.1
Oil temperature degC   50 48 52
Stop lever angle_04
Pump speed r/min   2500 2500 2500
Pressure kPa   716 677 755
Pressure kgf/cm2   7.3 6.9 7.7
Oil temperature degC   55 52 58
0000001101
Pump speed r/min   900 900 900
Timer stroke with S/T ON mm   4.6 4.4 4.8
Timer stroke with S/T OFF mm   2.8 2.4 3.2
Basic   *
Oil temperature degC   50 48 52
Remarks
ON
 
_02
Pump speed r/min   900 900 900
Timer stroke with S/T ON mm   4.6 4.3 4.9
Timer stroke with S/T OFF mm   2.8 2.3 3.3
Basic   *
Oil temperature degC   50 48 52
_03
Pump speed r/min   1200 1200 1200
Timer stroke with S/T ON mm   6.1 5.6 6.6
Oil temperature degC   50 48 52
_04
Pump speed r/min   1800 1800 1800
Timer stroke with S/T ON mm   9.1 8.4 9.8
Oil temperature degC   50 48 52
_05
Pump speed r/min   2300 2300 2300
Timer stroke with S/T ON mm   11.05 10.6 11.5
Oil temperature degC   52 50 54
0000001201
Max. applied voltage V   8 8 8
Test voltage V   13 12 14
Timing setting
K dimension mm   3.3 3.2 3.4
KF dimension mm   7.22 7.12 7.32
MS dimension mm   1.8 1.7 1.9
Control lever angle alpha deg.   23 19 27
Control lever angle beta deg.   42.5 37.5 47.5

Test data Ex:

0000001801 POTENTIOMETER ADJUSTMENT

Test data 104760-2511
Adjustment of the potentiometer Adjusting method (dummy bolt method) 1. Position the control lever at the adjusting points in the table, hold the dummy bolt against the lever and fix. 2. In the fixed position, install the potentiometer so that the output voltage is V1 (supply voltage Vi). 3. After completing potentiometer installation, remove the dummy bolt. A:Standard point B:Checking point C:Control lever angle I:Idle position F:Full speed position N:Pump speed Q:Injection quantity Vo:Output voltage M:Connecting diagram for the potentiometer O:Output P:Output when (2) and (3) connected.
----------
V1=3.2+-0.03(V) Vi=10(V)
----------
N1=600(r/min) Q1=16.9+-1.0(mm3/st) V1=3.2+-0.03(V) V2=(1.6+-0.7(V)) V3=(8.5+-0.9(V)) a=(9.6(deg)) b=0(deg) c=(42.5(deg)) Vi=10(V)

0000001901 W-CSD ADJUSTMENT

Test data 104760-2511
Adjustment of the W-CSD Adjust screw (A) so that the timer stroke is as determined from the graph and the formula. Formula t (deg C) <= 10 TA = 2.05 10<= t (deg C) <= 20 TA = -0.019t+2.24 20 < t (deg C) <= 55 TA = -0.0531t + 2.922 X:Temperature t (deg C) Y:Timer stroke TA B:Timer stroke graph
----------

----------

0000002001 DASHPOT ADJUSTMENT

Test data 104760-2511
(1)Adjustment of the dash pot 1. Insert a block gauge L1 between the idle set screw (C) and the bracket (D). 2. In the above condition, adjust the locknut (B) so that the dashpot adjusting (A) contacts the pushrod, and then fix the locknut (Tightening torque T). 3.The dashpot and control lever contact faces must be smooth. Confirm that the control lever returns to the idle position. (2)ISC actuator installation In the idle position, fix the actuator bracket (F) so that the clearance between the control lever and the ISC lever roller (E) is L2.
----------
T=6~9N?m(0.6~0.9kgf?m) L1=2.7+-0.05(mm) L2=1.0+1.0-0.5(mm)
----------
L1=2.7+-0.05(mm) L2=1.0+1.0-0.5(mm)




Have questions with 104760-2511?





Group cross 104760-2511 ZEXEL

9 460 613 078 
 
INJECTION-PUMP ASSEMBLY
104760-2511  
 
 
INJECTION-PUMP ASSEMBLY

Nissan 

9 460 613 079 
1670081T00 
INJECTION-PUMP ASSEMBLY
RD28
9 460 611 043 
1670081T02 
INJECTION-PUMP ASSEMBLY
RD28
9 460 611 988 
1670081T03 
INJECTION-PUMP ASSEMBLY
RD28
9 460 611 989 
1670081T04 
INJECTION-PUMP ASSEMBLY
RD28
9 460 611 057 
1670084T03 
INJECTION-PUMP ASSEMBLY
RD28
9 460 611 462 
1670084T04 
INJECTION-PUMP ASSEMBLY
RD28