Rating:
Information injection-pump assembly
ZEXEL
104760-2370
1047602370
NISSAN
1670060S15
1670060s15
Cross reference number
ZEXEL
104760-2370
1047602370
NISSAN
1670060S15
1670060s15
Zexel num
Bosch num
Firm num
Name
104760-2370
1670060S15 NISSAN
INJECTION-PUMP ASSEMBLY
RD28 *
RD28 *
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105780-0060
Bosch type code
NP-DN0SD1510
Nozzle holder
105780-2150
Opening pressure
MPa
13
13
13.3
Opening pressure
kgf/cm2
133
133
136
Injection pipe
157805-7320
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-450
Inside diameter - outside diameter - length (mm) mm 2-6-450
Joint assembly
157641-4720
Tube assembly
157641-4020
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
32
31.6
32.4
Difference in delivery
mm3/st.
2
Basic
*
Injection timing adjustment_02
Pump speed
r/min
2600
2600
2600
Average injection quantity
mm3/st.
27
24.5
29.5
Injection timing adjustment_03
Pump speed
r/min
2500
2500
2500
Average injection quantity
mm3/st.
31.5
29.4
33.6
Injection timing adjustment_04
Pump speed
r/min
2300
2300
2300
Average injection quantity
mm3/st.
31.2
29.2
33.2
Injection timing adjustment_05
Pump speed
r/min
1800
1800
1800
Average injection quantity
mm3/st.
33
31
35
Injection timing adjustment_06
Pump speed
r/min
1200
1200
1200
Average injection quantity
mm3/st.
32
30.5
33.5
Injection timing adjustment_07
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
32
31.1
32.9
Injection timing adjustment_08
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
32.9
31.1
34.7
Injection quantity adjustment
Pump speed
r/min
2600
2600
2600
Average injection quantity
mm3/st.
27
25
29
Difference in delivery
mm3/st.
4.5
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
2800
2800
2800
Average injection quantity
mm3/st.
6.5
Governor adjustment
Pump speed
r/min
290
290
290
Average injection quantity
mm3/st.
9
8
10
Difference in delivery
mm3/st.
1.7
Basic
*
Remarks
At difference in delivery adjustment, 2.6 or less after repeated measurements.
At difference in delivery adjustment, 2.6 or less after repeated measurements.
Governor adjustment_02
Pump speed
r/min
290
290
290
Average injection quantity
mm3/st.
9
8
10
Governor adjustment_03
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
3
Boost compensator adjustment
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
14.5
8
21
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
43
43
Difference in delivery
mm3/st.
15
Basic
*
Speed control lever angle
Pump speed
r/min
290
290
290
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
Speed control lever angle_02
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
0000000901
Pump speed
r/min
900
900
900
Overflow quantity
cm3/min
390
258
522
Stop lever angle
Pump speed
r/min
900
900
900
Pressure
kPa
372.5
343
402
Pressure
kgf/cm2
3.8
3.5
4.1
Basic
*
Stop lever angle_02
Pump speed
r/min
900
900
900
Pressure
kPa
372.5
343
402
Pressure
kgf/cm2
3.8
3.5
4.1
Stop lever angle_03
Pump speed
r/min
1800
1800
1800
Pressure
kPa
578.5
549
608
Pressure
kgf/cm2
5.9
5.6
6.2
Stop lever angle_04
Pump speed
r/min
2500
2500
2500
Pressure
kPa
745.5
716
775
Pressure
kgf/cm2
7.6
7.3
7.9
0000001101
Pump speed
r/min
900
900
900
Timer stroke
mm
2.9
2.7
3.1
Basic
*
_02
Pump speed
r/min
900
900
900
Timer stroke
mm
2.9
2.7
3.1
_03
Pump speed
r/min
1200
1200
1200
Timer stroke
mm
4.6
4.2
5
_04
Pump speed
r/min
1800
1800
1800
Timer stroke
mm
8.1
7.7
8.5
_05
Pump speed
r/min
2300
2300
2300
Timer stroke
mm
9.75
9.3
10.2
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
Timing setting
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
7.24
7.14
7.34
MS dimension
mm
1.8
1.7
1.9
Control lever angle alpha
deg.
23
19
27
Control lever angle beta
deg.
42
37
47
Control lever angle gamma
deg.
11
10.5
11.5
Test data Ex:
0000001801 DASHPOT ADJUSTMENT
(1)Adjustment of the dash pot
1. Insert a block gauge L1 between the idle set screw (C) and the bracket (D).
2. In the above condition, adjust the locknut (B) so that the dashpot adjusting (A) contacts the pushrod, and then fix the locknut (Tightening torque T).
3.The dashpot and control lever contact faces must be smooth. Confirm that the control lever returns to the idle position.
(2)ISC actuator installation
In the idle position, fix the actuator bracket (F) so that the clearance between the control lever and the ISC lever roller (E) is L2.
----------
T=6~7N-m(0.6~0.7kgf-m) L1=2.7+-0.05mm L2=1.0+1.0-0.5mm
----------
L1=2.7+-0.05mm L2=1.0+1.0-0.5mm
----------
T=6~7N-m(0.6~0.7kgf-m) L1=2.7+-0.05mm L2=1.0+1.0-0.5mm
----------
L1=2.7+-0.05mm L2=1.0+1.0-0.5mm
0000001901 POTENTIOMETER ADJUSTMENT
Adjustment of the potentiometer
At pump speed N1 and a control lever position a from idle (gap L1), calculate the injection quantity and convert it to a voltage value. Then adjust the potentiometer.
Voltage conversion formula: V+-0.05 = 0.0459Q+2.4249 (V: voltage, Q: injection quantity)
Confirm at least V1 at the control lever full position.
X:Injection quantity
Y:Voltage
M:Connecting diagram for the potentiometer
O:Output
P:Output when (2) and (3) connected.
Vi:Applied voltage
----------
N1=600r/min a=11deg L1=6mm V1=6V Vi=10V
----------
----------
N1=600r/min a=11deg L1=6mm V1=6V Vi=10V
----------
Have questions with 104760-2370?
Group cross 104760-2370 ZEXEL
Nissan
Nissan
Nissan
Nissan
104760-2370
1670060S15
INJECTION-PUMP ASSEMBLY
RD28
RD28