Rating:
Information injection-pump assembly
ZEXEL
104749-6520
1047496520
ISUZU
8944240810
8944240810
Cross reference number
ZEXEL
104749-6520
1047496520
ISUZU
8944240810
8944240810
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Pump speed
r/min
1250
1250
1250
Average injection quantity
mm3/st.
35.1
34.6
35.6
Difference in delivery
mm3/st.
3
Basic
*
Injection timing adjustment_02
Pump speed
r/min
2550
2550
2550
Average injection quantity
mm3/st.
8.85
5.3
12.4
Injection timing adjustment_03
Pump speed
r/min
2175
2175
2175
Average injection quantity
mm3/st.
32.2
29.7
34.7
Injection timing adjustment_04
Pump speed
r/min
1250
1250
1250
Average injection quantity
mm3/st.
35.1
34.1
36.1
Injection timing adjustment_05
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
34.2
31.7
36.7
Injection quantity adjustment
Pump speed
r/min
2550
2550
2550
Average injection quantity
mm3/st.
8.85
5.8
11.9
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
2700
2700
2700
Average injection quantity
mm3/st.
3
Governor adjustment
Pump speed
r/min
375
375
375
Average injection quantity
mm3/st.
6.9
4.9
8.9
Difference in delivery
mm3/st.
2
Basic
*
Governor adjustment_02
Pump speed
r/min
375
375
375
Average injection quantity
mm3/st.
6.9
4.9
8.9
Governor adjustment_03
Pump speed
r/min
450
450
450
Average injection quantity
mm3/st.
3
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
63
Basic
*
Speed control lever angle
Pump speed
r/min
375
375
375
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
0000000901
Pump speed
r/min
1000
1000
1000
Overflow quantity
cm3/min
420
288
552
Stop lever angle
Pump speed
r/min
1000
1000
1000
Pressure
kPa
402
382
422
Pressure
kgf/cm2
4.1
3.9
4.3
Basic
*
Stop lever angle_02
Pump speed
r/min
250
250
250
Pressure
kPa
186.5
157
216
Pressure
kgf/cm2
1.9
1.6
2.2
Stop lever angle_03
Pump speed
r/min
1000
1000
1000
Pressure
kPa
402
382
422
Pressure
kgf/cm2
4.1
3.9
4.3
Stop lever angle_04
Pump speed
r/min
1500
1500
1500
Pressure
kPa
529.5
500
559
Pressure
kgf/cm2
5.4
5.1
5.7
Stop lever angle_05
Pump speed
r/min
2175
2175
2175
Pressure
kPa
676.5
647
706
Pressure
kgf/cm2
6.9
6.6
7.2
0000001101
Pump speed
r/min
1000
1000
1000
Timer stroke
mm
1.8
1.6
2
Basic
*
_02
Pump speed
r/min
780
780
780
Timer stroke
mm
0.5
0.5
0.5
_03
Pump speed
r/min
1000
1000
1000
Timer stroke
mm
1.8
1.5
2.1
_04
Pump speed
r/min
1500
1500
1500
Timer stroke
mm
4.9
4.3
5.5
_05
Pump speed
r/min
2100
2100
2100
Timer stroke
mm
8.6
8
9.2
_06
Pump speed
r/min
2175
2175
2175
Timer stroke
mm
9
8.6
9.4
_07
Pump speed
r/min
450
450
450
Remarks
C.D.. cancel speed.
C.D.. cancel speed.
_08
Pump speed
r/min
0
0
0
Timer stroke
mm
3.3
3.1
3.5
_09
Pump speed
r/min
450
450
450
Remarks
C.D.. cancel speed.
C.D.. cancel speed.
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
0000001501
Pump speed
r/min
1250
1250
1250
Atmospheric pressure difference
kPa
-21.9
-22.6
-21.2
Atmospheric pressure difference
mmHg
-164
-169
-159
Decrease qty
mm3/st.
5.25
3.5
7
Basic
*
_02
Pump speed
r/min
1250
1250
1250
Atmospheric pressure difference
kPa
-21.9
-22.6
-21.2
Atmospheric pressure difference
mmHg
-164
-169
-159
Decrease qty
mm3/st.
5.25
2.8
7.7
Timing setting
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
5.8
5.7
5.9
MS dimension
mm
1.6
1.5
1.7
Control lever angle alpha
deg.
15
11
19
Control lever angle beta
deg.
38
33
43
Test data Ex:
0000001501 ANEROID COMPENSATOR
ACS adjustment
Full load injection quantity at high altitudes and ACS adjusting method
1. Full load injection quantity adjustment
(1)Remove the ACS cover and remove the bellows and adjusting shim.
(2)Perform all adjustments as per the adjustment standard except for ACS adjustment.
2. ACS adjustment
(1)Assemble the ACS cover, bellows and adjusting shim.
(2)At pump speed N1, adjust using a shim to obtain the decrease for the altitude shown in the table.
X1 = atmospheric pressure
X2 = altitude
Y = decrease quantity
(A) = adjustment value
(B) = test value
----------
N1=1250r/min
----------
----------
N1=1250r/min
----------
0000001801 V-FICD ADJUSTMENT
Adjustment of the V-FICD (vacuum-type fast idle control device)
1. Adjust the actuator rod so that the clearance between the control lever(A) and the actuator rod is L.
2. Apply negative pressure P1 {P2} to the actuator and confirm that it moves through its full stroke.
(A) Control lever
(B): lock nut
(C): Actuator
(D): Stroke adjusting screw
----------
L=0.9+-0.2mm P1=-53.3kPa P2=-400mmHg
----------
L=0.9+-0.2mm T=1.2~1.5N-m(0.12~0.15kgf-m)
----------
L=0.9+-0.2mm P1=-53.3kPa P2=-400mmHg
----------
L=0.9+-0.2mm T=1.2~1.5N-m(0.12~0.15kgf-m)