104749-6240 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1047496240 8944052421


104749-6240 INJECTION-PUMP ASSEMBLY
Rating:
63
Buy INJECTION-PUMP ASSEMBLY 104749-6240 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 104749-6240 1047496240
ISUZU 8944052421 8944052421

Cross reference number

ZEXEL 104749-6240 1047496240
ISUZU 8944052421 8944052421


Zexel num
Bosch num
Firm num
Name
104749-6240 
104749-6370 
 
8944052421  ISUZU
INJECTION-PUMP ASSEMBLY
4FC1J * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105000-2010
Bosch type code   NP-DN12SD12TT
Nozzle holder   105780-2080
Opening pressure MPa   14.7 14.7 15.19
Opening pressure kgf/cm2   150 150 155
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-840
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   40.2 39.7 40.7
Difference in delivery mm3/st.   3.5
Basic   *
Injection timing adjustment_02
Pump speed r/min   2650 2650 2650
Average injection quantity mm3/st.   13.3 9.8 16.8
Injection timing adjustment_03
Pump speed r/min   2350 2350 2350
Average injection quantity mm3/st.   34.2 32.1 36.3
Injection timing adjustment_04
Pump speed r/min   2000 2000 2000
Average injection quantity mm3/st.   35.2 33.2 37.2
Injection timing adjustment_05
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   40.2 39.2 41.2
Injection timing adjustment_06
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   39.1 37.1 41.1
Injection quantity adjustment
Pump speed r/min   2650 2650 2650
Average injection quantity mm3/st.   13.3 10.3 16.3
Difference in delivery mm3/st.   4
Basic   *
Injection quantity adjustment_02
Pump speed r/min   2800 2800 2800
Average injection quantity mm3/st.   5
Governor adjustment
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   8.8 6.8 10.8
Difference in delivery mm3/st.   2
Basic   *
Governor adjustment_02
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   8.8 6.8 10.8
Governor adjustment_03
Pump speed r/min   475 475 475
Average injection quantity mm3/st.   3
Timer adjustment
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   60 60
Basic   *
Speed control lever angle
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   0 0 0
Remarks
Magnet OFF
 
0000000901
Pump speed r/min   1250 1250 1250
Overflow quantity cm3/min   420 288 552
Stop lever angle
Pump speed r/min   1250 1250 1250
Pressure kPa   431.5 412 451
Pressure kgf/cm2   4.4 4.2 4.6
Basic   *
Stop lever angle_02
Pump speed r/min   600 600 600
Pressure kPa   255 226 284
Pressure kgf/cm2   2.6 2.3 2.9
Stop lever angle_03
Pump speed r/min   1250 1250 1250
Pressure kPa   431.5 412 451
Pressure kgf/cm2   4.4 4.2 4.6
Stop lever angle_04
Pump speed r/min   2050 2050 2050
Pressure kPa   647.5 618 677
Pressure kgf/cm2   6.6 6.3 6.9
0000001101
Pump speed r/min   1250 1250 1250
Timer stroke mm   3.9 3.7 4.1
Basic   *
_02
Pump speed r/min   630 530 730
Timer stroke mm   0.5 0.5 0.5
_03
Pump speed r/min   1250 1250 1250
Timer stroke mm   3.9 3.6 4.2
_04
Pump speed r/min   1750 1750 1750
Timer stroke mm   6.6 6 7.2
_05
Pump speed r/min   2050 2050 2050
Timer stroke mm   8.2 7.8 8.6
0000001201
Max. applied voltage V   8 8 8
Test voltage V   13 12 14
0000001401
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   33.2 32.7 33.7
Timer stroke variation dT mm   0.9 0.7 1.1
Basic   *
_02
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   33.2 32.2 34.2
Timer stroke variation dT mm   0.9 0.5 1.3
_03
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   25.2 23.7 26.7
Timer stroke variation dT mm   1.8 1.3 2.3
Timing setting
K dimension mm   3.3 3.2 3.4
KF dimension mm   5.8 5.7 5.9
MS dimension mm   1.6 1.5 1.7
Control lever angle alpha deg.   24.5 20.5 28.5
Control lever angle beta deg.   45 40 50

Test data Ex:

0000001801 MICROSWITCH ADJUSTMENT

Microswitch adjustment With the control lever 'a' from the idle position (idle stopper lever clearance L), adjust the position of the microswitch and fix it in the position where it goes OFF. After adjustment, the microswitch must not turn OFF at lever position between idle and a. Also, the microswitch lever must not contact the stopper.
----------
a=31.5+-1deg L=10.3+-0.2mm
----------

0000001901 W-CSD ADJUSTMENT

Test data 104749-6240
Adjustment of the W-CSD 1. Adjustment of the timer stroke Adjust screw (A) so that the timer stroke is the value determined from the graph. (1) Timer stroke (mm), TA = -0.0215t+0.75 2 Lever angle (deg) theta =-0.1285t+5.43 (3) Lever position (mm) L=-0.04225t+1.775 (3 shows the gap between the control lever and the idle set screw.) 2. Adjustment of the position of the intermediate lever. Insert a shim L1 between the control lever (I) and the idle set screw (G). Align the intermediate lever (F) with the aligning line (J) and fix screw (E) so that it contacts the control lever. 3. W-CSD adjustment Insert a shim L1+-0.05 between the control lever (I) and the idle set screw (G). Use adjusting screw (B) to fix the CSD lever (C) in the position where it operates the intermediate lever (F) via the rod (D). X = temperature t (deg C) Y1 = timer stroke (mm) Y2 = control lever position (deg)
----------
L1=0.93+-0.05mm
----------




Have questions with 104749-6240?





Group cross 104749-6240 ZEXEL

Isuzu 

 
8941698061 
INJECTION-PUMP ASSEMBLY
4EC1T
9 460 613 718 
8944039270 
INJECTION-PUMP ASSEMBLY
4FD1
9 460 613 719 
8944039280 
INJECTION-PUMP ASSEMBLY
4FD1
9 460 615 069 
8944052401 
INJECTION-PUMP ASSEMBLY
4FC1J
104749-6240  

104749-6370 
 
8944052421 
INJECTION-PUMP ASSEMBLY
4FC1J
9 460 615 052 
8944052541 
INJECTION-PUMP ASSEMBLY
4FC1J
9 460 615 053 
8944052431 
INJECTION-PUMP ASSEMBLY
4FC1J
9 460 615 054 
8944052461 
INJECTION-PUMP ASSEMBLY
4FC1J
Back to top