104749-6120 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1047496120 8941433320


104749-6120 INJECTION-PUMP ASSEMBLY
Rating:
50
Buy INJECTION-PUMP ASSEMBLY 104749-6120 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 104749-6120 1047496120
ISUZU 8941433320 8941433320

Cross reference number

ZEXEL 104749-6120 1047496120
ISUZU 8941433320 8941433320


Zexel num
Bosch num
Firm num
Name
104749-6120 
104749-6121 
 
8941433320  ISUZU
INJECTION-PUMP ASSEMBLY
4FC1D *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105000-2010
Bosch type code   NP-DN12SD12TT
Nozzle holder   105780-2080
Opening pressure MPa   14.7 14.7 15.19
Opening pressure kgf/cm2   150 150 155
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-840
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   32.5 32 33
Difference in delivery mm3/st.   2.5
Basic   *
Injection timing adjustment_02
Pump speed r/min   2600 2600 2600
Average injection quantity mm3/st.   15.2 13.2 17.2
Injection timing adjustment_03
Pump speed r/min   2250 2250 2250
Average injection quantity mm3/st.   31.5 29.4 33.6
Injection timing adjustment_04
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   32.5 31.5 33.5
Injection timing adjustment_05
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   26.5 24.5 28.5
Injection quantity adjustment
Pump speed r/min   2600 2600 2600
Average injection quantity mm3/st.   15.5 14.5 16.5
Difference in delivery mm3/st.   4.5
Basic   *
Injection quantity adjustment_02
Pump speed r/min   2900 2900 2900
Average injection quantity mm3/st.   5
Governor adjustment
Pump speed r/min   330 330 330
Average injection quantity mm3/st.   7.6 5.6 9.6
Difference in delivery mm3/st.   2
Basic   *
Governor adjustment_02
Pump speed r/min   330 330 330
Average injection quantity mm3/st.   7.6 5.6 9.6
Governor adjustment_03
Pump speed r/min   450 450 450
Average injection quantity mm3/st.   0 0 0
Timer adjustment
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   60 50 70
Basic   *
Speed control lever angle
Pump speed r/min   330 330 330
Average injection quantity mm3/st.   0 0 0
Remarks
Magnet OFF
 
0000000901
Pump speed r/min   1250 1250 1250
Overflow quantity cm3/min   480 348 612
Stop lever angle
Pump speed r/min   1250 1250 1250
Pressure kPa   470.5 451 490
Pressure kgf/cm2   4.8 4.6 5
Basic   *
Stop lever angle_02
Pump speed r/min   1250 1250 1250
Pressure kPa   470.5 451 490
Pressure kgf/cm2   4.8 4.6 5
Stop lever angle_03
Pump speed r/min   2000 2000 2000
Pressure kPa   637.5 608 667
Pressure kgf/cm2   6.5 6.2 6.8
0000001101
Pump speed r/min   1250 1250 1250
Timer stroke mm   3.9 3.7 4.1
Basic   *
_02
Pump speed r/min   1250 1250 1250
Timer stroke mm   3.9 3.6 4.2
_03
Pump speed r/min   1800 1800 1800
Timer stroke mm   6.7 6.1 7.3
_04
Pump speed r/min   2250 2250 2250
Timer stroke mm   9 8.6 9.4
0000001201
Max. applied voltage V   8 8 8
Test voltage V   13 12 14
0000001501
Pump speed r/min   1250 1250 1250
Atmospheric pressure difference kPa   -21.9 -22.6 -21.2
Atmospheric pressure difference mmHg   -164 -169 -159
Decrease qty mm3/st.   3.4 2.4 4.4
Basic   *
_02
Pump speed r/min   1250 1250 1250
Atmospheric pressure difference kPa   -21.9 -22.6 -21.2
Atmospheric pressure difference mmHg   -164 -169 -159
Decrease qty mm3/st.   3.4 1.7 5.1
Timing setting
K dimension mm   3.3 3.2 3.4
KF dimension mm   5.8 5.7 5.9
MS dimension mm   1.6 1.5 1.7
Pre-stroke mm   0.25 0.23 0.27
Control lever angle alpha deg.   -3 -7 1
Control lever angle beta deg.   37 32 42

Test data Ex:

0000001501 ANEROID COMPENSATOR

Test data 104749-6120
ACS adjustment Full load injection quantity at high altitudes and ACS adjusting method 1. Full load injection quantity adjustment (1)Remove the ACS cover and remove the bellows and adjusting shim. (2)Perform all adjustments as per the adjustment standard except for ACS adjustment. 2. ACS adjustment Adjust the ACS so that the reduction amount corresponds to the altitude in the table. X1 = atmospheric pressure X2 = altitude Y = decrease quantity (A) = adjustment value (B) = test value
----------
N1=1250r/min
----------




Have questions with 104749-6120?





Group cross 104749-6120 ZEXEL

Isuzu 

 
8941451140 
INJECTION-PUMP ASSEMBLY
4FD1
 
 
INJECTION-PUMP ASSEMBLY
4FC1J
9 460 613 717 
8941769860 
INJECTION-PUMP ASSEMBLY
4FC1J
104749-6120  

104749-6121 
 
8941433320 
INJECTION-PUMP ASSEMBLY
4FC1D
9 460 615 051 
8944102530 
INJECTION-PUMP ASSEMBLY
4FC1D
 
8941782600 
INJECTION-PUMP ASSEMBLY
4FC1-J
 
8941782610 
INJECTION-PUMP ASSEMBLY
4FC1-J
 
8941782680 
INJECTION-PUMP ASSEMBLY
4FC1-J
 
8941782700 
INJECTION-PUMP ASSEMBLY
4FC1-J
 
8941782620 
INJECTION-PUMP ASSEMBLY
4FC1J
9 460 614 718 
 
INJECTION-PUMP ASSEMBLY
 
8941698051 
INJECTION-PUMP ASSEMBLY
4EC1T