Rating:
Information injection-pump assembly
ZEXEL
104748-2222
1047482222
Cross reference number
ZEXEL
104748-2222
1047482222
Zexel num
Bosch num
Firm num
Name
104748-2222
INJECTION-PUMP ASSEMBLY
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Pump speed
r/min
1200
1200
1200
Average injection quantity
mm3/st.
29.1
28.6
29.6
Difference in delivery
mm3/st.
2.5
Basic
*
Oil temperature
degC
50
48
52
Injection timing adjustment_02
Pump speed
r/min
2700
2700
2700
Average injection quantity
mm3/st.
14.9
11.4
18.4
Oil temperature
degC
55
52
58
Injection timing adjustment_03
Pump speed
r/min
2500
2500
2500
Average injection quantity
mm3/st.
27.7
25.7
29.7
Oil temperature
degC
55
52
58
Injection timing adjustment_04
Pump speed
r/min
1200
1200
1200
Average injection quantity
mm3/st.
29.1
28.1
30.1
Oil temperature
degC
50
48
52
Injection timing adjustment_05
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
26.3
24.3
28.3
Oil temperature
degC
50
48
52
Injection quantity adjustment
Pump speed
r/min
2700
2700
2700
Average injection quantity
mm3/st.
14.9
11.9
17.9
Basic
*
Oil temperature
degC
55
52
58
Injection quantity adjustment_02
Pump speed
r/min
2900
2900
2900
Average injection quantity
mm3/st.
6
Oil temperature
degC
55
52
58
Governor adjustment
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
6.8
5.3
8.3
Difference in delivery
mm3/st.
3
Basic
*
Oil temperature
degC
48
46
50
Governor adjustment_02
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
6.8
4.8
8.8
Oil temperature
degC
48
46
50
Governor adjustment_03
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
3
Oil temperature
degC
50
48
52
Boost compensator adjustment
Pump speed
r/min
700
700
700
Average injection quantity
mm3/st.
15
10
20
Oil temperature
degC
50
48
52
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
50.3
45.3
55.3
Basic
*
Oil temperature
degC
48
46
50
Remarks
Refer to additional devices.
Refer to additional devices.
Speed control lever angle
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
0
0
0
Oil temperature
degC
48
46
50
Remarks
Magnet OFF
Magnet OFF
0000000901
Pump speed
r/min
1200
1200
1200
Overflow quantity
cm3/min
348
216
480
Oil temperature
degC
50
48
52
Stop lever angle
Pump speed
r/min
1200
1200
1200
Pressure
kPa
333.5
304
363
Pressure
kgf/cm2
3.4
3.1
3.7
Basic
*
Oil temperature
degC
50
48
52
Stop lever angle_02
Pump speed
r/min
1200
1200
1200
Pressure
kPa
333.5
294
373
Pressure
kgf/cm2
3.4
3
3.8
Oil temperature
degC
50
48
52
Stop lever angle_03
Pump speed
r/min
1800
1800
1800
Pressure
kPa
470.5
431
510
Pressure
kgf/cm2
4.8
4.4
5.2
Oil temperature
degC
50
48
52
Stop lever angle_04
Pump speed
r/min
2500
2500
2500
Pressure
kPa
637.5
598
677
Pressure
kgf/cm2
6.5
6.1
6.9
Oil temperature
degC
55
52
58
0000001101
Pump speed
r/min
1200
1200
1200
Timer stroke
mm
2.6
2.3
2.9
Basic
*
Oil temperature
degC
50
48
52
_02
Pump speed
r/min
800
800
800
Timer stroke
mm
1.1
0.5
1.7
Oil temperature
degC
50
48
52
_03
Pump speed
r/min
1200
1200
1200
Timer stroke
mm
2.6
2.2
3
Oil temperature
degC
50
48
52
_04
Pump speed
r/min
2500
2500
2500
Timer stroke
mm
7.95
7.4
8.5
Oil temperature
degC
55
52
58
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
0000001501
Pump speed
r/min
1200
1200
1200
Atmospheric pressure difference
kPa
-18.7
-19.4
-18
Atmospheric pressure difference
mmHg
-140
-145
-135
Decrease qty
mm3/st.
2.6
1.1
4.1
Oil temperature
degC
50
48
52
Timing setting
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
5.8
5.7
5.9
MS dimension
mm
1.8
1.7
1.9
Control lever angle alpha
deg.
24
20
28
Control lever angle beta
deg.
44
39
49
Control lever angle gamma
deg.
14
13.5
14.5
Test data Ex:
0000001501 ANEROID COMPENSATOR
ACS adjustment
Full load injection quantity at high altitudes and ACS adjusting method
1. Full load injection quantity adjustment
(1)Remove the ACS cover and remove the bellows and adjusting shim.
(2)Perform all adjustments as per the adjustment standard except for ACS adjustment.
2. ACS adjustment
Adjust the ACS so that the reduction amount corresponds to the altitude in the table.
X1 = atmospheric pressure
X2 = altitude
Y = decrease quantity
(A) = adjustment value
(B) = test value
----------
N1=1200r/min
----------
----------
N1=1200r/min
----------
0000001801 POTENTIOMETER ADJUSTMENT
Adjustment of the potentiometer
At pump speed N = N1 r/min and with the control lever angle at a from the idle position (corresponding to a shim thickness of L mm), convert the injection quantity obtained to a voltage value using the graph and adjust the potentiometer.
Vi:Applied voltage
E = conversion expression
Vo = output voltage
Q = injection quantity
----------
N1=700r/min a=14deg L=8.9mm
----------
J=V+-0.05=0.187Q+1.593 V Vi=-V
----------
N1=700r/min a=14deg L=8.9mm
----------
J=V+-0.05=0.187Q+1.593 V Vi=-V
0000001901 STARTING I/Q ADJUSTMENT
Starting injection quantity adjustment
Adjust the adjusting bolt (A) so that the starting injection quantity is within the standard and fix using the locknut (B).
(C) Stop lever
----------
----------
----------
----------
0000002001 W-CSD ADJUSTMENT
Adjustment of the W-CSD
1. Timer advance adjustment (refer to Fig 1 [O], 3 [Q]).
(1)Determine the timer advance angle from the graph in Fig. 3 (Q).
(2)(1) Adjust with the screw (A) so that the timer advance angle determined in the item (1) is obtained.
2. Setting the intermediate lever position (refer to fig 1 and fig 2)
(1)Insert a block gauge L1 between the idling set screw (G) and the control lever (F).
(2)Align the intermediate lever (D) with the aligning line and position it perpendicularly. Adjust the screw (E) so that it contacts the control lever (F) and then tighten the nut.
3. W-CSD lever adjustment [refer to fig 1 (O) and fig 2 (P)]
(1)Insert a block gauge L2 determined from the graph (L-t) in figure 3 (Q) between the idling set screw (G) and the control lever (F).
(2)Fix screw (B) so that the W-CSD lever (C)'s roller contacts the intermediate lever (D).
Note:
Apply red paint after adjustment.
When inserting the block gauge, separate lever (C) and (D) using screw (B) to prevent excessive force on the lever.
X = temperature t (V)
Y1 = timer lift TA (mm)
Y2 = control lever dimension L mm (control lever position
J = graph TA - t
-10 <= t (deg C) <= 20: TA = -0.0367t + 1.284
20 <= t (deg C) <= 40: TA = -0.0275t + 1.1
K:Graph L-X:
-10<= t (deg C) <= 20: L = -0.0867t + 3.63
20 <= t (deg C) <= 40: L = -0.075 t + 3.4
----------
L1=1.9+-0.05mm L2=L+-0.05mm a=30degC
----------
----------
L1=1.9+-0.05mm L2=L+-0.05mm a=30degC
----------
Have questions with 104748-2222?
Group cross 104748-2222 ZEXEL
Nissan
104748-2222
INJECTION-PUMP ASSEMBLY