104748-2190 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1047482190


104748-2190 INJECTION-PUMP ASSEMBLY
Rating:
64
Buy INJECTION-PUMP ASSEMBLY 104748-2190 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 104748-2190 1047482190

Cross reference number

ZEXEL 104748-2190 1047482190


Zexel num
Bosch num
Firm num
Name
104748-2190 
 
   
INJECTION-PUMP ASSEMBLY

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105000-2010
Bosch type code   NP-DN12SD12TT
Nozzle holder   105780-2080
Opening pressure MPa   14.7 14.7 15.19
Opening pressure kgf/cm2   150 150 155
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-840
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Pump speed r/min   1200 1200 1200
Average injection quantity mm3/st.   29.1 28.6 29.6
Difference in delivery mm3/st.   2.5
Basic   *
Injection timing adjustment_02
Pump speed r/min   2700 2700 2700
Average injection quantity mm3/st.   14.9 11.4 18.4
Injection timing adjustment_03
Pump speed r/min   2500 2500 2500
Average injection quantity mm3/st.   27.7 25.7 29.7
Injection timing adjustment_04
Pump speed r/min   1200 1200 1200
Average injection quantity mm3/st.   29.1 28.1 30.1
Injection timing adjustment_05
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   26.3 24.3 28.3
Injection quantity adjustment
Pump speed r/min   2700 2700 2700
Average injection quantity mm3/st.   14.9 11.9 17.9
Basic   *
Injection quantity adjustment_02
Pump speed r/min   2900 2900 2900
Average injection quantity mm3/st.   6
Governor adjustment
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   9.8 8.3 11.3
Difference in delivery mm3/st.   3
Basic   *
Governor adjustment_02
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   9.8 7.8 11.8
Governor adjustment_03
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   3
Boost compensator adjustment
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   16.65 13.3 20
Remarks
From idle
 
Timer adjustment
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   50.3 45.3 55.3
Basic   *
Speed control lever angle
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   0 0 0
Remarks
Magnet OFF
 
0000000901
Pump speed r/min   1200 1200 1200
Overflow quantity cm3/min   348 216 480
Stop lever angle
Pump speed r/min   1200 1200 1200
Pressure kPa   333.5 304 363
Pressure kgf/cm2   3.4 3.1 3.7
Basic   *
Stop lever angle_02
Pump speed r/min   1200 1200 1200
Pressure kPa   333.5 294 373
Pressure kgf/cm2   3.4 3 3.8
Stop lever angle_03
Pump speed r/min   1800 1800 1800
Pressure kPa   470.5 431 510
Pressure kgf/cm2   4.8 4.4 5.2
Stop lever angle_04
Pump speed r/min   2500 2500 2500
Pressure kPa   637.5 598 677
Pressure kgf/cm2   6.5 6.1 6.9
0000001101
Pump speed r/min   1200 1200 1200
Timer stroke mm   2.6 2.3 2.9
Basic   *
_02
Pump speed r/min   1200 1200 1200
Timer stroke mm   2.6 2.2 3
_03
Pump speed r/min   1800 1800 1800
Timer stroke mm   4.9 4.3 5.5
_04
Pump speed r/min   2500 2500 2500
Timer stroke mm   8 7.4 8.6
0000001201
Max. applied voltage V   8 8 8
Test voltage V   13 12 14
0000001501
Pump speed r/min   1200 1200 1200
Atmospheric pressure difference kPa   -18.7 -19.4 -18
Atmospheric pressure difference mmHg   -140 -145 -135
Average injection quantity mm3/st.   25.7 24.9 26.5
Decrease qty mm3/st.   2.6 1.8 3.4
Decrease rate %   9.2 6.2 12.2
Basic   *
_02
Pump speed r/min   1200 1200 1200
Atmospheric pressure difference kPa   -18.7 -19.4 -18
Atmospheric pressure difference mmHg   -140 -145 -135
Decrease qty mm3/st.   2.6 1.1 4.1
Timing setting
K dimension mm   3.3 3.2 3.4
KF dimension mm   5.8 5.7 5.9
MS dimension mm   1.8 1.7 1.9
Control lever angle alpha deg.   24 20 28
Control lever angle beta deg.   42 37 47
Control lever angle gamma
From idle
deg.   11 10.5 11.5

Test data Ex:

0000001501 ANEROID COMPENSATOR

Test data 104748-2190
ACS adjustment Full load injection quantity at high altitudes and ACS adjusting method 1. Full load injection quantity adjustment (1)Remove the ACS cover and remove the bellows and adjusting shim. (2)Perform all adjustments as per the adjustment standard except for ACS adjustment. 2. ACS adjustment (1)Assemble the ACS cover, bellows and adjusting shim. (2)At N = N1, adjust using shims so that the decrease amount for altitude is as specified in the graph. N:Pump speed X1:Atmospheric pressure X2:Altitude Y:Decrease quantity A:Adjustment value B:Inspection value
----------
N1=1200r/min
----------

0000001801 POTENTIOMETER ADJUSTMENT

Test data 104748-2190
Adjustment of the potentiometer At pump speed N1 and oil temperature t1, and at lever angle a (L1) from idle, adjust the potentiometer so that the specifications are satisfied.
----------
N1=700r/min t1=48~52degC a=11deg L1=7mm V=0.187Q+1.593
----------

0000001901 W-CSD ADJUSTMENT

Test data 104748-2190
Adjustment of the W-CSD 1. Adjustment of the advance angle of the timer (1)Determine the timer advance angle using the graph. Graph TA-t: -10<= t(deg C) <= 20 TA = -0.028t+1.367 20 <= t (deg C) <= 60: TA = -0.02 t + 1.2 Graph L-t: 10 <= t (deg C) <= 20 L = -0.0667t+3.23 20 <= t (deg C) <= 60: L = -0.05 t + 2.9 (2)(1) Adjust with the screw (A) so that the timer advance angle determined in the item (1) is obtained. 2. Setting the intermediate lever position (1)Insert a block gauge L1 between the idling set screw (G) and the control lever (F). (2)Align the intermediate lever (D) with the aligning line (I) and position it perpendicularly. Fix screw (E) so that it contacts the control lever (F). 3. W-CSD lever adjustment (1)Insert a block gauge L2 determined from the graph L - t in 1. (1) between the idle set screw (G) and the control lever (F). (2)Fix screw (B) so that the W-CSD lever (C)'s roller contacts the intermediate lever (D). (3)Adjust the screw (B) until the screw (F) contacts the control lever (G). Then fix locknut (A). Note: The temperature of the wax at adjustment must not exceed a. When inserting the block gauge, separate lever (C) and (D) using screw (B) to prevent excessive force on the lever. X:Temperature t (deg C) Y1:Timer lift TA (mm) Y2:Control lever L dimension [mm; control lever position (deg)] (U) Perpendicular position
----------
L1=1.0+-0.05mm L2=L1+-0.05mm a=30degC
----------
L1=1.0+-0.05mm




Have questions with 104748-2190?





Group cross 104748-2190 ZEXEL

Nissan 

9 460 610 483 
1670016A01 
INJECTION-PUMP ASSEMBLY
CD17
9 460 610 484 
1670016A06 
INJECTION-PUMP ASSEMBLY
CD17
9 460 613 684 
1670016A11 
INJECTION-PUMP ASSEMBLY
CD17
9 460 613 685 
1670016A16 
INJECTION-PUMP ASSEMBLY
CD17
9 460 610 058 
1670016A61 
INJECTION-PUMP ASSEMBLY
CD17
9 460 610 059 
1670016A66 
INJECTION-PUMP ASSEMBLY
CD17
9 460 610 060 
1670016A71 
INJECTION-PUMP ASSEMBLY
CD17
9 460 610 061 
1670016A76 
INJECTION-PUMP ASSEMBLY
CD17
9 460 610 273 
 
INJECTION-PUMP ASSEMBLY

Nissan 

 
1670017A01 
INJECTION-PUMP ASSEMBLY
CD17
9 460 614 640 
1670017A20 
INJECTION-PUMP ASSEMBLY
CD17
104748-2190  
 
 
INJECTION-PUMP ASSEMBLY

Nissan 

 
1670017A06 
INJECTION-PUMP ASSEMBLY
CD17
9 460 614 641 
1670017A21 
INJECTION-PUMP ASSEMBLY
CD17
Back to top