Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Pump speed
r/min
1200
1200
1200
Average injection quantity
mm3/st.
29.1
28.6
29.6
Difference in delivery
mm3/st.
2.5
Basic
*
Injection timing adjustment_02
Pump speed
r/min
2700
2700
2700
Average injection quantity
mm3/st.
14.9
11.4
18.4
Injection timing adjustment_03
Pump speed
r/min
2500
2500
2500
Average injection quantity
mm3/st.
27.7
25.7
29.7
Injection timing adjustment_04
Pump speed
r/min
1200
1200
1200
Average injection quantity
mm3/st.
29.1
28.1
30.1
Injection timing adjustment_05
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
26.3
24.3
28.3
Injection quantity adjustment
Pump speed
r/min
2700
2700
2700
Average injection quantity
mm3/st.
14.9
11.9
17.9
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
2900
2900
2900
Average injection quantity
mm3/st.
6
Governor adjustment
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
9.8
8.3
11.3
Difference in delivery
mm3/st.
3
Basic
*
Governor adjustment_02
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
9.8
7.8
11.8
Governor adjustment_03
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
3
Boost compensator adjustment
Pump speed
r/min
700
700
700
Average injection quantity
mm3/st.
16.65
13.3
20
Remarks
From idle
From idle
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
50.3
45.3
55.3
Basic
*
Speed control lever angle
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
0000000901
Pump speed
r/min
1200
1200
1200
Overflow quantity
cm3/min
348
216
480
Stop lever angle
Pump speed
r/min
1200
1200
1200
Pressure
kPa
333.5
304
363
Pressure
kgf/cm2
3.4
3.1
3.7
Basic
*
Stop lever angle_02
Pump speed
r/min
1200
1200
1200
Pressure
kPa
333.5
294
373
Pressure
kgf/cm2
3.4
3
3.8
Stop lever angle_03
Pump speed
r/min
1800
1800
1800
Pressure
kPa
470.5
431
510
Pressure
kgf/cm2
4.8
4.4
5.2
Stop lever angle_04
Pump speed
r/min
2500
2500
2500
Pressure
kPa
637.5
598
677
Pressure
kgf/cm2
6.5
6.1
6.9
0000001101
Pump speed
r/min
1200
1200
1200
Timer stroke
mm
2.6
2.3
2.9
Basic
*
_02
Pump speed
r/min
1200
1200
1200
Timer stroke
mm
2.6
2.2
3
_03
Pump speed
r/min
1800
1800
1800
Timer stroke
mm
4.9
4.3
5.5
_04
Pump speed
r/min
2500
2500
2500
Timer stroke
mm
8
7.4
8.6
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
0000001501
Pump speed
r/min
1200
1200
1200
Atmospheric pressure difference
kPa
-18.7
-19.4
-18
Atmospheric pressure difference
mmHg
-140
-145
-135
Average injection quantity
mm3/st.
25.7
24.9
26.5
Decrease qty
mm3/st.
2.6
1.8
3.4
Decrease rate
%
9.2
6.2
12.2
Basic
*
_02
Pump speed
r/min
1200
1200
1200
Atmospheric pressure difference
kPa
-18.7
-19.4
-18
Atmospheric pressure difference
mmHg
-140
-145
-135
Decrease qty
mm3/st.
2.6
1.1
4.1
Timing setting
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
5.8
5.7
5.9
MS dimension
mm
1.8
1.7
1.9
Control lever angle alpha
deg.
24
20
28
Control lever angle beta
deg.
42
37
47
Control lever angle gamma
From idle deg. 11 10.5 11.5
From idle deg. 11 10.5 11.5
Test data Ex:
0000001501 ANEROID COMPENSATOR
ACS adjustment
Full load injection quantity at high altitudes and ACS adjusting method
1. Full load injection quantity adjustment
(1)Remove the ACS cover and remove the bellows and adjusting shim.
(2)Perform all adjustments as per the adjustment standard except for ACS adjustment.
2. ACS adjustment
(1)Assemble the ACS cover, bellows and adjusting shim.
(2)At N = N1, adjust using shims so that the decrease amount for altitude is as specified in the graph.
N:Pump speed
X1:Atmospheric pressure
X2:Altitude
Y:Decrease quantity
A:Adjustment value
B:Inspection value
----------
N1=1200r/min
----------
----------
N1=1200r/min
----------
0000001801 POTENTIOMETER ADJUSTMENT
Adjustment of the potentiometer
At pump speed N1 and oil temperature t1, and at lever angle a (L1) from idle, adjust the potentiometer so that the specifications are satisfied.
----------
N1=700r/min t1=48~52degC a=11deg L1=7mm V=0.187Q+1.593
----------
----------
N1=700r/min t1=48~52degC a=11deg L1=7mm V=0.187Q+1.593
----------
0000001901 W-CSD ADJUSTMENT
Adjustment of the W-CSD
1. Adjustment of the advance angle of the timer
(1)Determine the timer advance angle using the graph.
Graph TA-t: -10<= t(deg C) <= 20 TA = -0.028t+1.367
20 <= t (deg C) <= 60: TA = -0.02 t + 1.2
Graph L-t: 10 <= t (deg C) <= 20 L = -0.0667t+3.23
20 <= t (deg C) <= 60: L = -0.05 t + 2.9
(2)(1) Adjust with the screw (A) so that the timer advance angle determined in the item (1) is obtained.
2. Setting the intermediate lever position
(1)Insert a block gauge L1 between the idling set screw (G) and the control lever (F).
(2)Align the intermediate lever (D) with the aligning line (I) and position it perpendicularly. Fix screw (E) so that it contacts the control lever (F).
3. W-CSD lever adjustment
(1)Insert a block gauge L2 determined from the graph L - t in 1. (1) between the idle set screw (G) and the control lever (F).
(2)Fix screw (B) so that the W-CSD lever (C)'s roller contacts the intermediate lever (D).
(3)Adjust the screw (B) until the screw (F) contacts the control lever (G). Then fix locknut (A).
Note:
The temperature of the wax at adjustment must not exceed a.
When inserting the block gauge, separate lever (C) and (D) using screw (B) to prevent excessive force on the lever.
X:Temperature t (deg C)
Y1:Timer lift TA (mm)
Y2:Control lever L dimension [mm; control lever position (deg)]
(U) Perpendicular position
----------
L1=1.0+-0.05mm L2=L1+-0.05mm a=30degC
----------
L1=1.0+-0.05mm
----------
L1=1.0+-0.05mm L2=L1+-0.05mm a=30degC
----------
L1=1.0+-0.05mm
Have questions with 104748-2190?
Group cross 104748-2190 ZEXEL
Nissan
Nissan
104748-2190
INJECTION-PUMP ASSEMBLY