Rating:
Information injection-pump assembly
ZEXEL
104748-1800
1047481800
ISUZU
8943235550
8943235550
Cross reference number
ZEXEL
104748-1800
1047481800
ISUZU
8943235550
8943235550
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Pump speed
r/min
800
800
800
Average injection quantity
mm3/st.
29
28.5
29.5
Difference in delivery
mm3/st.
2.5
Basic
*
Oil temperature
degC
50
48
52
Injection timing adjustment_02
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
26.5
24.5
28.5
Oil temperature
degC
48
46
50
Injection timing adjustment_03
Pump speed
r/min
800
800
800
Average injection quantity
mm3/st.
29
28
30
Difference in delivery
mm3/st.
2.5
Basic
*
Oil temperature
degC
50
48
52
Injection quantity adjustment
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
24
23
25
Difference in delivery
mm3/st.
6
Basic
*
Oil temperature
degC
50
48
52
Injection quantity adjustment_02
Pump speed
r/min
1100
1100
1100
Average injection quantity
mm3/st.
3
Oil temperature
degC
50
48
52
Injection quantity adjustment_03
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
24
23
25
Difference in delivery
mm3/st.
6
Basic
*
Oil temperature
degC
50
48
52
Governor adjustment
Pump speed
r/min
375
375
375
Average injection quantity
mm3/st.
7.5
5.5
9.5
Difference in delivery
mm3/st.
2
Basic
*
Oil temperature
degC
48
46
50
Governor adjustment_02
Pump speed
r/min
375
375
375
Average injection quantity
mm3/st.
7.5
5.5
9.5
Difference in delivery
mm3/st.
2
Basic
*
Oil temperature
degC
48
46
50
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
45
41.5
48.5
Basic
*
Oil temperature
degC
48
46
50
Remarks
Full
Full
Timer adjustment_02
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
45
41.5
48.5
Oil temperature
degC
48
46
50
Speed control lever angle
Pump speed
r/min
375
375
375
Average injection quantity
mm3/st.
0
0
0
Oil temperature
degC
48
46
50
Remarks
Magnet OFF at idling position
Magnet OFF at idling position
0000000901
Pump speed
r/min
600
600
600
Overflow quantity
cm3/min
320
190
450
Oil temperature
degC
50
48
52
Stop lever angle
Pump speed
r/min
600
600
600
Pressure
kPa
294
274
314
Pressure
kgf/cm2
3
2.8
3.2
Basic
*
Oil temperature
degC
50
48
52
Stop lever angle_02
Pump speed
r/min
600
600
600
Pressure
kPa
294
265
323
Pressure
kgf/cm2
3
2.7
3.3
Basic
*
Oil temperature
degC
50
48
52
Stop lever angle_03
Pump speed
r/min
850
850
850
Pressure
kPa
353
314
392
Pressure
kgf/cm2
3.6
3.2
4
Oil temperature
degC
50
48
52
0000001101
Pump speed
r/min
1200
Timer stroke
mm
0
0
0
Basic
*
Oil temperature
degC
50
48
52
0000001201
Max. applied voltage
V
16
16
16
Test voltage
V
25
24
26
Timing setting
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
5.8
5.7
5.9
MS dimension
mm
2.1
2
2.2
Control lever angle alpha
deg.
25
21
29
Control lever angle beta
deg.
22
17
27
Test data Ex:
0000001801 STARTING I/Q ADJUSTMENT
Starting injection quantity adjustment
Adjust the adjusting bolt A so that the starting injection quantity adjustment is within the standards. Fix using the nut B.
(C) Stop lever
L:Adjustment dimensions
----------
L=3.7~7.8mm
----------
L=3.7~7.8mm
----------
L=3.7~7.8mm
----------
L=3.7~7.8mm