Rating:
Information injection-pump assembly
ZEXEL
104748-1750
1047481750
ISUZU
8944756690
8944756690
Cross reference number
ZEXEL
104748-1750
1047481750
ISUZU
8944756690
8944756690
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Pump speed
r/min
1250
1250
1250
Average injection quantity
mm3/st.
31
30.5
31.5
Difference in delivery
mm3/st.
2.5
Basic
*
Oil temperature
degC
50
48
52
Injection timing adjustment_02
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
29.5
28
31
Oil temperature
degC
50
48
52
Injection timing adjustment_03
Pump speed
r/min
1250
1250
1250
Average injection quantity
mm3/st.
31
30
32
Difference in delivery
mm3/st.
2.5
Basic
*
Oil temperature
degC
50
48
52
Injection timing adjustment_04
Pump speed
r/min
2500
2500
2500
Average injection quantity
mm3/st.
26.8
25.3
28.3
Oil temperature
degC
55
52
58
Injection timing adjustment_05
Pump speed
r/min
2600
2600
2600
Average injection quantity
mm3/st.
26.7
25.1
28.3
Oil temperature
degC
55
52
58
Injection timing adjustment_06
Pump speed
r/min
2700
2700
2700
Average injection quantity
mm3/st.
25.1
22.1
28.1
Oil temperature
degC
55
52
58
Injection quantity adjustment
Pump speed
r/min
2800
2650
2950
Average injection quantity
mm3/st.
20.8
19.8
21.8
Basic
*
Oil temperature
degC
55
52
58
Injection quantity adjustment_02
Pump speed
r/min
2900
2900
2900
Average injection quantity
mm3/st.
4
Oil temperature
degC
55
52
58
Injection quantity adjustment_03
Pump speed
r/min
2800
2650
2950
Average injection quantity
mm3/st.
20.8
19.8
21.8
Oil temperature
degC
55
52
58
Governor adjustment
Pump speed
r/min
425
425
425
Average injection quantity
mm3/st.
6
5
7
Difference in delivery
mm3/st.
2
Basic
*
Oil temperature
degC
48
46
50
Governor adjustment_02
Pump speed
r/min
425
425
425
Average injection quantity
mm3/st.
6
5
7
Difference in delivery
mm3/st.
2
Oil temperature
degC
48
46
50
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
50
50
70
Basic
*
Oil temperature
degC
48
46
50
Remarks
Full
Full
Timer adjustment_02
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
50
50
Oil temperature
degC
48
46
50
Speed control lever angle
Pump speed
r/min
425
425
425
Average injection quantity
mm3/st.
0
0
0
Oil temperature
degC
48
46
50
Remarks
Magnet OFF at idling position
Magnet OFF at idling position
0000000901
Pump speed
r/min
1250
1250
1250
Overflow quantity
cm3/min
370
240
500
Oil temperature
degC
50
48
52
Stop lever angle
Pump speed
r/min
1250
1250
1250
Pressure
kPa
431
411
451
Pressure
kgf/cm2
4.4
4.2
4.6
Basic
*
Oil temperature
degC
50
48
52
Stop lever angle_02
Pump speed
r/min
1250
1250
1250
Pressure
kPa
431
411
451
Pressure
kgf/cm2
4.4
4.2
4.6
Basic
*
Oil temperature
degC
50
48
52
Stop lever angle_03
Pump speed
r/min
2000
2000
2000
Pressure
kPa
628
599
657
Pressure
kgf/cm2
6.4
6.1
6.7
Oil temperature
degC
50
48
52
Stop lever angle_04
Pump speed
r/min
2150
2150
2150
Pressure
kPa
667
638
696
Pressure
kgf/cm2
6.8
6.5
7.1
Oil temperature
degC
52
50
54
0000001101
Pump speed
r/min
1250
1250
1250
Timer stroke
mm
3.4
3.2
3.6
Basic
*
Oil temperature
degC
50
48
52
_02
Pump speed
r/min
710
610
810
Timer stroke
mm
0.5
0.5
0.5
Oil temperature
degC
50
48
52
_03
Pump speed
r/min
1250
1250
1250
Timer stroke
mm
3.4
3.2
3.6
Basic
*
Oil temperature
degC
50
48
52
_04
Pump speed
r/min
2000
2000
2000
Timer stroke
mm
7.4
7
7.8
Oil temperature
degC
50
48
52
_05
Pump speed
r/min
2150
2150
2150
Timer stroke
mm
8.2
7.9
8.6
Oil temperature
degC
52
50
54
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
0000001401
Pump speed
r/min
1250
1250
1250
Average injection quantity
mm3/st.
21
20.5
21.5
Timer stroke TA
mm
2.3
2.3
2.3
Timer stroke variation dT
mm
1.1
0.9
1.3
Basic
*
Oil temperature
degC
50
48
52
_02
Pump speed
r/min
1250
1250
1250
Average injection quantity
mm3/st.
31
30
32
Timer stroke variation dT
mm
0
0
0
Oil temperature
degC
50
48
52
_03
Pump speed
r/min
1250
1250
1250
Average injection quantity
mm3/st.
21
20
22
Timer stroke variation dT
mm
1.1
0.7
1.5
Basic
*
Oil temperature
degC
50
48
52
_04
Pump speed
r/min
1250
1250
1250
Average injection quantity
mm3/st.
11
10
12
Timer stroke variation dT
mm
2.2
1.7
2.7
Oil temperature
degC
50
48
52
Timing setting
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
5.8
5.7
5.9
MS dimension
mm
1.6
1.5
1.7
Control lever angle alpha
deg.
20
16
24
Control lever angle beta
deg.
40
39
41
Test data Ex:
0000001801 V-FICD ADJUSTMENT
Adjustment of the V-FICD (perform with W-FICD released)
1. Adjust to obtain L1.
2. Set at L2 when negative pressure P1 is applied to the actuator.
Adjust the stroke using the actuator stroke adjusting screw (F).
(A) Pin
(B) Actuator shaft
(C) Control lever
(D) Actuator
(E) Lock nut (Torque T)
----------
L1=1+1mm L2=1.45+-0.1mm P1=-46.7kPa(-350mmHg) T=1.2~1.5N-m(0.12~0.15kgf-m)
----------
L1=1+1mm L2=1.45+-0.1mm T=1.2~1.5N-m(0.12~0.15kgf-m)
----------
L1=1+1mm L2=1.45+-0.1mm P1=-46.7kPa(-350mmHg) T=1.2~1.5N-m(0.12~0.15kgf-m)
----------
L1=1+1mm L2=1.45+-0.1mm T=1.2~1.5N-m(0.12~0.15kgf-m)
0000001901 W-CSD ADJUSTMENT
Adjustment of the W-CSD
1. Adjustment of the timer stroke
Adjust using screw (A) so that the timer stroke is the value determined using the graph (W). [(K), (M)]
2. Adjustment of the position of the intermediate lever.
With a shim L inserted between the control lever (I) and the FICD set screw (E), insert a shim L1 between (I) and the idle screw (G).
Align the intermediate lever (F) with the aligning mark (J) and then fix the intermediate lever adjusting screw (E) so that (E) contacts the control lever (I). [(U), (V)]
3. Adjustment of the FICD
Insert a shim L1 between the control lever (I) and the idle set screw (G).
Use adjusting screw (B) to fix the CSD lever (C) in the position where it operates the intermediate lever (F) via the rod (D). [(U), (V), (W)]
(O) Timer stroke adjustment (mm)
(P) Lever position (deg)
(Q) lever position (mm)
The (Q) indicates the clearance between the control lever and the idle set screw.
X:Temperature t (deg C)
Y1:Timer stroke TA (mm)
Y2:Control lever position at theta L (deg, mm)
(R) Cooling water temperature (deg C)
(S) Cooling water temperature: increase direction
N:Pump speed
(M) Timer piston stroke (mm)
(K) Lever angle (deg)
(Z) Lever position (mm)
a:Standard point
----------
L=1.2+-0.05mm L1=L+-0.05mm
----------
L3=1.2+-0.05mm L5=- N=500r/min R1=20degC R2=-20degC M1=0.7+-0.2mm M2=1.6+-0.4mm K1=3.6+-1deg K2=6.1+-3deg Z1=1.2+-0.3mm Z2=2+-1mm
----------
L=1.2+-0.05mm L1=L+-0.05mm
----------
L3=1.2+-0.05mm L5=- N=500r/min R1=20degC R2=-20degC M1=0.7+-0.2mm M2=1.6+-0.4mm K1=3.6+-1deg K2=6.1+-3deg Z1=1.2+-0.3mm Z2=2+-1mm