Rating:
Information injection-pump assembly
ZEXEL
104748-1720
1047481720
Cross reference number
ZEXEL
104748-1720
1047481720
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Pump speed
r/min
1500
1500
1500
Average injection quantity
mm3/st.
31.4
30.9
31.9
Difference in delivery
mm3/st.
2.5
Basic
*
Injection timing adjustment_02
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
29.9
27.9
31.9
Injection timing adjustment_03
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
30.4
28.4
32.4
Injection timing adjustment_04
Pump speed
r/min
1500
1500
1500
Average injection quantity
mm3/st.
31.4
30.4
32.4
Difference in delivery
mm3/st.
2.5
Basic
*
Injection timing adjustment_05
Pump speed
r/min
2000
2000
2000
Average injection quantity
mm3/st.
30.1
28.1
32.1
Injection timing adjustment_06
Pump speed
r/min
2400
2400
2400
Average injection quantity
mm3/st.
28.4
26.4
30.4
Injection timing adjustment_07
Pump speed
r/min
2600
2600
2600
Average injection quantity
mm3/st.
27.6
25.5
29.7
Difference in delivery
mm3/st.
3.5
Injection quantity adjustment
Pump speed
r/min
2850
2850
2850
Average injection quantity
mm3/st.
15.9
12.9
18.9
Difference in delivery
mm3/st.
3.5
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
2700
2700
2700
Average injection quantity
mm3/st.
26.8
23.3
30.3
Injection quantity adjustment_03
Pump speed
r/min
2850
2850
2850
Average injection quantity
mm3/st.
15.9
12.4
19.4
Difference in delivery
mm3/st.
3.5
Basic
*
Injection quantity adjustment_04
Pump speed
r/min
2975
2975
2975
Average injection quantity
mm3/st.
6
Governor adjustment
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
9.6
7.6
11.6
Difference in delivery
mm3/st.
2
Basic
*
Governor adjustment_02
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
9.6
7.6
11.6
Difference in delivery
mm3/st.
2
Governor adjustment_03
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
5
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
45
45
65
Basic
*
Remarks
Full
Full
Speed control lever angle
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF at idling position
Magnet OFF at idling position
0000000901
Pump speed
r/min
1250
1250
1250
Overflow quantity
cm3/min
570
440
700
Stop lever angle
Pump speed
r/min
1250
1250
1250
Pressure
kPa
362.5
343
382
Pressure
kgf/cm2
3.7
3.5
3.9
Basic
*
Stop lever angle_02
Pump speed
r/min
500
500
500
Pressure
kPa
186
157
215
Pressure
kgf/cm2
1.9
1.6
2.2
Stop lever angle_03
Pump speed
r/min
1250
1250
1250
Pressure
kPa
363
334
392
Pressure
kgf/cm2
3.7
3.4
4
Basic
*
Stop lever angle_04
Pump speed
r/min
1500
1500
1500
Pressure
kPa
412
383
441
Pressure
kgf/cm2
4.2
3.9
4.5
Stop lever angle_05
Pump speed
r/min
2000
2000
2000
Pressure
kPa
539
510
568
Pressure
kgf/cm2
5.5
5.2
5.8
Stop lever angle_06
Pump speed
r/min
2300
2300
2300
Pressure
kPa
618
589
647
Pressure
kgf/cm2
6.3
6
6.6
0000001101
Pump speed
r/min
1250
1250
1250
Timer stroke
mm
2.9
2.7
3.1
Basic
*
_02
Pump speed
r/min
620
620
620
Timer stroke
mm
0.5
0.1
1.1
_03
Pump speed
r/min
1250
1250
1250
Timer stroke
mm
2.9
2.6
3.2
Basic
*
_04
Pump speed
r/min
1500
1500
1500
Timer stroke
mm
4.2
3.7
4.7
_05
Pump speed
r/min
2000
2000
2000
Timer stroke
mm
6.1
5.5
6.7
_06
Pump speed
r/min
2300
2300
2300
Timer stroke
mm
7.4
7
7.8
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
0000001401
Pump speed
r/min
1250
1250
1250
Average injection quantity
mm3/st.
18
17.5
18.5
Timer stroke variation dT
mm
0.8
0.6
1
Basic
*
_02
Pump speed
r/min
1250
1250
1250
Average injection quantity
mm3/st.
18
17
19
Timer stroke variation dT
mm
0.8
0.5
1.1
Basic
*
_03
Pump speed
r/min
1250
1250
1250
Average injection quantity
mm3/st.
7
5.5
8.5
Timer stroke variation dT
mm
2.2
1.7
2.7
Timing setting
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
5.8
5.7
5.9
MS dimension
mm
1.4
1.3
1.5
Control lever angle alpha
deg.
20
16
24
Control lever angle beta
deg.
45
40
50
Test data Ex:
0000001801 W-CSD ADJUSTMENT
Adjustment of the W-CSD
1. Adjustment of the timer stroke
Adjust using screw (A) so that the timer stroke is the value determined using the graph (W) and the formula. [(U), (W)]
2. Adjustment of the position of the intermediate lever.
Insert a shim L1 between the control lever (I) and the idle set screw (G).
Align the intermediate lever (F) with the aligning line (J) and fix intermediate lever's adjusting screw (E) so that it contacts the control lever. [(U), (V)]
3. Adjustment of the FICD
Insert a shim between the control lever (I) and the idle set screw (G). Then, fix the CSD lever (C) in the position where it operates the intermediate lever (F) via the rod (D) using the adjusting screw (B). [(U), (V), (W)]
(J) Aligning mark
(T) Timer stroke (mm)
(P) Lever position (deg)
(L) Lever position (mm). Shows gap between control lever and idle set screw
X:Temperature t (deg C)
Y1:Timer stroke TA (mm)
Y2:Control lever position (deg, mm)
(R) Cooling water temperature (deg C)
(S) Cooling water temperature: increase direction
N:Pump speed
(M) Timer piston stroke (mm)
(K) Lever angle (deg)
(Z) Lever position (mm)
----------
L1=1.2+-0.05mm L=L1+-0.05mm
----------
L1=1.2+-0.05mm N=500r/min R1=20deg R2=-20deg M1=0.16+-0.2mm M2=1.0+-0.4mm K1=3.6+-1deg K2=6.1+-3deg Z1=1.2+-0.3mm Z2=2+-1mm
----------
L1=1.2+-0.05mm L=L1+-0.05mm
----------