104748-1720 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1047481720


104748-1720 INJECTION-PUMP ASSEMBLY
Rating:
19
Buy INJECTION-PUMP ASSEMBLY 104748-1720 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 104748-1720 1047481720

Cross reference number

ZEXEL 104748-1720 1047481720


Zexel num
Bosch num
Firm num
Name
104748-1720 
104748-1723 
 
  ISUZU
INJECTION-PUMP ASSEMBLY
4EC1 *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105000-2010
Bosch type code   NP-DN12SD12TT
Nozzle holder   105780-2080
Opening pressure MPa   14.7 14.7 15.19
Opening pressure kgf/cm2   150 150 155
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-840
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Pump speed r/min   1500 1500 1500
Average injection quantity mm3/st.   31.4 30.9 31.9
Difference in delivery mm3/st.   2.5
Basic   *
Injection timing adjustment_02
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   29.9 27.9 31.9
Injection timing adjustment_03
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   30.4 28.4 32.4
Injection timing adjustment_04
Pump speed r/min   1500 1500 1500
Average injection quantity mm3/st.   31.4 30.4 32.4
Difference in delivery mm3/st.   2.5
Basic   *
Injection timing adjustment_05
Pump speed r/min   2000 2000 2000
Average injection quantity mm3/st.   30.1 28.1 32.1
Injection timing adjustment_06
Pump speed r/min   2400 2400 2400
Average injection quantity mm3/st.   28.4 26.4 30.4
Injection timing adjustment_07
Pump speed r/min   2600 2600 2600
Average injection quantity mm3/st.   27.6 25.5 29.7
Difference in delivery mm3/st.   3.5
Injection quantity adjustment
Pump speed r/min   2850 2850 2850
Average injection quantity mm3/st.   15.9 12.9 18.9
Difference in delivery mm3/st.   3.5
Basic   *
Injection quantity adjustment_02
Pump speed r/min   2700 2700 2700
Average injection quantity mm3/st.   26.8 23.3 30.3
Injection quantity adjustment_03
Pump speed r/min   2850 2850 2850
Average injection quantity mm3/st.   15.9 12.4 19.4
Difference in delivery mm3/st.   3.5
Basic   *
Injection quantity adjustment_04
Pump speed r/min   2975 2975 2975
Average injection quantity mm3/st.   6
Governor adjustment
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   9.6 7.6 11.6
Difference in delivery mm3/st.   2
Basic   *
Governor adjustment_02
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   9.6 7.6 11.6
Difference in delivery mm3/st.   2
Governor adjustment_03
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   5
Timer adjustment
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   45 45 65
Basic   *
Remarks
Full
 
Speed control lever angle
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   0 0 0
Remarks
Magnet OFF at idling position
 
0000000901
Pump speed r/min   1250 1250 1250
Overflow quantity cm3/min   570 440 700
Stop lever angle
Pump speed r/min   1250 1250 1250
Pressure kPa   362.5 343 382
Pressure kgf/cm2   3.7 3.5 3.9
Basic   *
Stop lever angle_02
Pump speed r/min   500 500 500
Pressure kPa   186 157 215
Pressure kgf/cm2   1.9 1.6 2.2
Stop lever angle_03
Pump speed r/min   1250 1250 1250
Pressure kPa   363 334 392
Pressure kgf/cm2   3.7 3.4 4
Basic   *
Stop lever angle_04
Pump speed r/min   1500 1500 1500
Pressure kPa   412 383 441
Pressure kgf/cm2   4.2 3.9 4.5
Stop lever angle_05
Pump speed r/min   2000 2000 2000
Pressure kPa   539 510 568
Pressure kgf/cm2   5.5 5.2 5.8
Stop lever angle_06
Pump speed r/min   2300 2300 2300
Pressure kPa   618 589 647
Pressure kgf/cm2   6.3 6 6.6
0000001101
Pump speed r/min   1250 1250 1250
Timer stroke mm   2.9 2.7 3.1
Basic   *
_02
Pump speed r/min   620 620 620
Timer stroke mm   0.5 0.1 1.1
_03
Pump speed r/min   1250 1250 1250
Timer stroke mm   2.9 2.6 3.2
Basic   *
_04
Pump speed r/min   1500 1500 1500
Timer stroke mm   4.2 3.7 4.7
_05
Pump speed r/min   2000 2000 2000
Timer stroke mm   6.1 5.5 6.7
_06
Pump speed r/min   2300 2300 2300
Timer stroke mm   7.4 7 7.8
0000001201
Max. applied voltage V   8 8 8
Test voltage V   13 12 14
0000001401
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   18 17.5 18.5
Timer stroke variation dT mm   0.8 0.6 1
Basic   *
_02
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   18 17 19
Timer stroke variation dT mm   0.8 0.5 1.1
Basic   *
_03
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   7 5.5 8.5
Timer stroke variation dT mm   2.2 1.7 2.7
Timing setting
K dimension mm   3.3 3.2 3.4
KF dimension mm   5.8 5.7 5.9
MS dimension mm   1.4 1.3 1.5
Control lever angle alpha deg.   20 16 24
Control lever angle beta deg.   45 40 50

Test data Ex:

0000001801 W-CSD ADJUSTMENT

Test data 104748-1720
Adjustment of the W-CSD 1. Adjustment of the timer stroke Adjust using screw (A) so that the timer stroke is the value determined using the graph (W) and the formula. [(U), (W)] 2. Adjustment of the position of the intermediate lever. Insert a shim L1 between the control lever (I) and the idle set screw (G). Align the intermediate lever (F) with the aligning line (J) and fix intermediate lever's adjusting screw (E) so that it contacts the control lever. [(U), (V)] 3. Adjustment of the FICD Insert a shim between the control lever (I) and the idle set screw (G). Then, fix the CSD lever (C) in the position where it operates the intermediate lever (F) via the rod (D) using the adjusting screw (B). [(U), (V), (W)] (J) Aligning mark (T) Timer stroke (mm) (P) Lever position (deg) (L) Lever position (mm). Shows gap between control lever and idle set screw X:Temperature t (deg C) Y1:Timer stroke TA (mm) Y2:Control lever position (deg, mm) (R) Cooling water temperature (deg C) (S) Cooling water temperature: increase direction N:Pump speed (M) Timer piston stroke (mm) (K) Lever angle (deg) (Z) Lever position (mm)
----------
L1=1.2+-0.05mm L=L1+-0.05mm
----------
L1=1.2+-0.05mm N=500r/min R1=20deg R2=-20deg M1=0.16+-0.2mm M2=1.0+-0.4mm K1=3.6+-1deg K2=6.1+-3deg Z1=1.2+-0.3mm Z2=2+-1mm




Have questions with 104748-1720?





Group cross 104748-1720 ZEXEL

Isuzu 

 
8944405181 
INJECTION-PUMP ASSEMBLY
4FE1
 
8944405182 
INJECTION-PUMP ASSEMBLY
4FE1
 
8944405183 
INJECTION-PUMP ASSEMBLY
4FE1
9 460 610 607 
8944405184 
INJECTION-PUMP ASSEMBLY
4FE1
 
8944638840 
INJECTION-PUMP ASSEMBLY
4FE1
 
8944638841 
INJECTION-PUMP ASSEMBLY
4FE1
 
8944638842 
INJECTION-PUMP ASSEMBLY
4FE1
9 460 612 345 
8944638843 
INJECTION-PUMP ASSEMBLY
4FE1
104748-1720  

104748-1723 
 
 
INJECTION-PUMP ASSEMBLY
4EC1
9 460 614 997 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

9 460 620 001 
8944685890 
INJECTION-PUMP ASSEMBLY
4EC1
 
8944593730 
INJECTION-PUMP ASSEMBLY
4FE1
 
8944593731 
INJECTION-PUMP ASSEMBLY
4FE1
9 460 610 620 
8944593732 
INJECTION-PUMP ASSEMBLY
4FE1
 
8944593810 
INJECTION-PUMP ASSEMBLY
4FE1
 
8944756690 
INJECTION-PUMP ASSEMBLY
4EC1AT
9 460 613 681 
8944756691 
INJECTION-PUMP ASSEMBLY
4EC1AT
9 460 615 009 
8944819080 
INJECTION-PUMP ASSEMBLY
4FB1P
9 460 610 330 
8943178480 
INJECTION-PUMP ASSEMBLY
4EC1
Back to top