Rating:
Information injection-pump assembly
ZEXEL
104746-6750
1047466750
ISUZU
8972263320
8972263320
Cross reference number
ZEXEL
104746-6750
1047466750
ISUZU
8972263320
8972263320
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105780-0060
Bosch type code
NP-DN0SD1510
Nozzle holder
105780-2150
Opening pressure
MPa
13
13
13.3
Opening pressure
kgf/cm2
133
133
136
Injection pipe
157805-7320
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-450
Inside diameter - outside diameter - length (mm) mm 2-6-450
Joint assembly
157641-4720
Tube assembly
157641-4020
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Pump speed
r/min
600
600
600
Boost pressure
kPa
22.7
21.4
24
Boost pressure
mmHg
170
160
180
Average injection quantity
mm3/st.
35.5
35
36
Difference in delivery
mm3/st.
3
Basic
*
Oil temperature
degC
50
48
52
Remarks
CBS
CBS
Injection timing adjustment_02
Pump speed
r/min
1225
1225
1225
Boost pressure
kPa
53.3
52
54.6
Boost pressure
mmHg
400
390
410
Average injection quantity
mm3/st.
59.4
58.9
59.9
Difference in delivery
mm3/st.
5
Basic
*
Oil temperature
degC
50
48
52
Remarks
Full
Full
Injection timing adjustment_03
Pump speed
r/min
500
500
500
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
29.8
25.8
33.8
Oil temperature
degC
48
46
50
Injection timing adjustment_04
Pump speed
r/min
600
600
600
Boost pressure
kPa
22.7
21.4
24
Boost pressure
mmHg
170
160
180
Average injection quantity
mm3/st.
35.5
34.5
36.5
Difference in delivery
mm3/st.
3.5
Basic
*
Oil temperature
degC
50
48
52
Remarks
CBS
CBS
Injection timing adjustment_05
Pump speed
r/min
1050
1050
1050
Boost pressure
kPa
53.3
52
54.6
Boost pressure
mmHg
400
390
410
Average injection quantity
mm3/st.
58
54.5
61.5
Oil temperature
degC
50
48
52
Injection timing adjustment_06
Pump speed
r/min
1225
1225
1225
Boost pressure
kPa
53.3
52
54.6
Boost pressure
mmHg
400
390
410
Average injection quantity
mm3/st.
59.4
58.4
60.4
Difference in delivery
mm3/st.
5
Basic
*
Oil temperature
degC
50
48
52
Remarks
Full
Full
Injection timing adjustment_07
Pump speed
r/min
1900
1900
1900
Boost pressure
kPa
53.3
52
54.6
Boost pressure
mmHg
400
390
410
Average injection quantity
mm3/st.
71.2
67.2
75.2
Oil temperature
degC
50
48
52
Injection quantity adjustment
Pump speed
r/min
2350
2350
2350
Boost pressure
kPa
53.3
52
54.6
Boost pressure
mmHg
400
390
410
Average injection quantity
mm3/st.
29.1
26.1
32.1
Difference in delivery
mm3/st.
6
Basic
*
Oil temperature
degC
52
50
54
Injection quantity adjustment_02
Pump speed
r/min
2700
2700
2700
Boost pressure
kPa
53.3
52
54.6
Boost pressure
mmHg
400
390
410
Average injection quantity
mm3/st.
5
Oil temperature
degC
55
52
58
Injection quantity adjustment_03
Pump speed
r/min
2350
2350
2350
Boost pressure
kPa
53.3
52
54.6
Boost pressure
mmHg
400
390
410
Average injection quantity
mm3/st.
29.1
26.1
32.1
Difference in delivery
mm3/st.
6
Basic
*
Oil temperature
degC
52
50
54
Governor adjustment
Pump speed
r/min
365
365
365
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
7.1
5.1
9.1
Difference in delivery
mm3/st.
2
Basic
*
Oil temperature
degC
48
46
50
Governor adjustment_02
Pump speed
r/min
365
365
365
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
7.1
5.1
9.1
Difference in delivery
mm3/st.
2
Basic
*
Oil temperature
degC
48
46
50
Timer adjustment
Pump speed
r/min
100
100
100
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
60
60
100
Basic
*
Oil temperature
degC
48
46
50
Remarks
Full
Full
Timer adjustment_02
Pump speed
r/min
100
100
100
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
60
60
100
Oil temperature
degC
48
46
50
Remarks
Full
Full
Speed control lever angle
Pump speed
r/min
365
365
365
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
0
0
0
Oil temperature
degC
48
46
50
Remarks
Magnet OFF at idling position
Magnet OFF at idling position
0000000901
Pump speed
r/min
1500
1500
1500
Boost pressure
kPa
53.3
52
54.6
Boost pressure
mmHg
400
390
410
Overflow quantity
cm3/min
650
520
780
Oil temperature
degC
50
48
52
Stop lever angle
Pump speed
r/min
1500
1500
1500
Boost pressure
kPa
53.3
52
54.6
Boost pressure
mmHg
400
390
410
Pressure
kPa
422
402
442
Pressure
kgf/cm2
4.3
4.1
4.5
Basic
*
Oil temperature
degC
50
48
52
Stop lever angle_02
Pump speed
r/min
1500
1500
1500
Boost pressure
kPa
53.3
52
54.6
Boost pressure
mmHg
400
390
410
Pressure
kPa
422
402
442
Pressure
kgf/cm2
4.3
4.1
4.5
Basic
*
Oil temperature
degC
50
48
52
0000001101
Pump speed
r/min
1500
1500
1500
Boost pressure
kPa
53.3
52
54.6
Boost pressure
mmHg
400
390
410
Timer stroke
mm
2.8
2.6
3
Basic
*
Oil temperature
degC
50
48
52
_02
Pump speed
r/min
1000
1000
1000
Boost pressure
kPa
53.3
52
54.6
Boost pressure
mmHg
400
390
410
Timer stroke
mm
0.5
Oil temperature
degC
50
48
52
_03
Pump speed
r/min
1500
1500
1500
Boost pressure
kPa
53.3
52
54.6
Boost pressure
mmHg
400
390
410
Timer stroke
mm
2.8
2.6
3
Basic
*
Oil temperature
degC
50
48
52
_04
Pump speed
r/min
1700
1700
1700
Boost pressure
kPa
53.3
52
54.6
Boost pressure
mmHg
400
390
410
Timer stroke
mm
3.8
3.4
4.2
Oil temperature
degC
50
48
52
_05
Pump speed
r/min
2150
2150
2150
Boost pressure
kPa
53.3
52
54.6
Boost pressure
mmHg
400
390
410
Timer stroke
mm
5.3
5
5.7
Oil temperature
degC
52
50
54
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
Timing setting
K dimension
mm
3.1
3
3.2
KF dimension
mm
5.5
5.4
5.6
MS dimension
mm
0.8
0.7
0.9
BCS stroke
mm
1.3
1.1
1.5
Pre-stroke
mm
0.45
0.43
0.47
Control lever angle alpha
deg.
18
14
22
Control lever angle beta
deg.
37
32
42
Test data Ex:
0000001801 POTENTIOMETER ADJUSTMENT
Adjusting method [applied voltage Vi, dummy bolt (C)]
1. Hold the dummy bolt (C) against the control lever at position N = N1, Q = Q1.
Fix using the lock nut.
2. When adjusting the potentiometer, position the control lever against the dummy bolt (C) and adjust the potentiometer so that the output voltage is V1 (V).
3. Remove the dummy bolt (C) after the completion of adjustment.
Confirm that the potentiometer output voltage is within the above mentioned standards between the control lever's adjusting point and the idling position.
N:Pump speed
V:Output voltage
Q:Injection quantity
P:Boost pressure
A:Adjusting point
B:Checking point
Q2:Idle
Q3:Full speed
(C): Dummy bolt
(D): Bracket for mounting the dummy bolt
(E): Part numbers of the dummy bolt and the nut
146526-3300 (bolt) 42L
013020-6040 (nut)
----------
N1=750r/min V1=4.10+-0.03V Q1=10.5+-1cm3/1,000st
----------
N1=750r/min N2=365r/min V1=41.0+-0.03V V2=(1.55+-0.45)V V3=(7.72+-0.83)V Q1=10.5+-1.0cm3/1,000st Q2=7.1+-2.0cm3/1,000st Idle Q3=Full speed P1=0kPa P2=0mmHg
----------
N1=750r/min V1=4.10+-0.03V Q1=10.5+-1cm3/1,000st
----------
N1=750r/min N2=365r/min V1=41.0+-0.03V V2=(1.55+-0.45)V V3=(7.72+-0.83)V Q1=10.5+-1.0cm3/1,000st Q2=7.1+-2.0cm3/1,000st Idle Q3=Full speed P1=0kPa P2=0mmHg