104746-5450 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1047465450 8973503950


104746-5450 INJECTION-PUMP ASSEMBLY
Rating:
39
Buy INJECTION-PUMP ASSEMBLY 104746-5450 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 104746-5450 1047465450
ISUZU 8973503950 8973503950

Cross reference number

ZEXEL 104746-5450 1047465450
ISUZU 8973503950 8973503950


Zexel num
Bosch num
Firm num
Name
104746-5450 
104746-5451 
 
8973503950  ISUZU
INJECTION-PUMP ASSEMBLY
4JA1-L * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105780-0060
Bosch type code   NP-DN0SD1510
Nozzle holder   105780-2150
Opening pressure MPa   13 13 13.3
Opening pressure kgf/cm2   133 133 136
Injection pipe   157805-7320
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-450
Joint assembly   157641-4720
Tube assembly   157641-4020
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Left
  L
(Solenoid timer adjustment condition)   OFF
Timer measuring device installation position
Low pressure side
  LOW PRESSURE SIDE
Injection timing adjustment
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   72.7 72.2 73.2
Difference in delivery mm3/st.   6
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_02
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   54.8 49.3 60.3
Oil temperature degC   48 46 50
Injection timing adjustment_03
Pump speed r/min   750 750 750
Average injection quantity mm3/st.   64.5 59 70
Oil temperature degC   50 48 52
Injection timing adjustment_04
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   71.4 65.9 76.9
Oil temperature degC   50 48 52
Injection timing adjustment_05
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   72.7 71.7 73.7
Difference in delivery mm3/st.   6
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_06
Pump speed r/min   1900 1900 1900
Average injection quantity mm3/st.   83.9 79.4 88.4
Oil temperature degC   50 48 52
Injection quantity adjustment
Pump speed r/min   2350 2350 2350
Average injection quantity mm3/st.   28.4 25.4 31.4
Difference in delivery mm3/st.   4
Basic   *
Oil temperature degC   52 50 54
Injection quantity adjustment_02
Pump speed r/min   2600 2600 2600
Average injection quantity mm3/st.   5
Oil temperature degC   55 52 58
Injection quantity adjustment_03
Pump speed r/min   2350 2350 2350
Average injection quantity mm3/st.   28.4 25.4 31.4
Difference in delivery mm3/st.   4
Basic   *
Oil temperature degC   52 50 54
Governor adjustment
Pump speed r/min   365 365 365
Average injection quantity mm3/st.   10.6 8.6 12.6
Difference in delivery mm3/st.   2
Basic   *
Oil temperature degC   48 46 50
Governor adjustment_02
Pump speed r/min   365 365 365
Average injection quantity mm3/st.   10.6 8.6 12.6
Difference in delivery mm3/st.   2
Basic   *
Oil temperature degC   48 46 50
Timer adjustment
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   90 70 110
Basic   *
Oil temperature degC   48 46 50
Remarks
Full
 
Timer adjustment_02
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   90 70 110
Oil temperature degC   48 46 50
Remarks
Full
 
Speed control lever angle
Pump speed r/min   365 365 365
Average injection quantity mm3/st.   0 0 0
Oil temperature degC   48 46 50
Remarks
Magnet OFF at idling position
 
0000000901
Pump speed r/min   1600 1600 1600
Overflow quantity with S/T ON cm3/min   1120 890 1350
Oil temperature degC   50 48 52
Stop lever angle
Pump speed r/min   1600 1600 1600
Pressure with S/T ON kPa   667 628 706
Pressure with S/T ON kgf/cm2   6.8 6.4 7.2
Pressure with S/T OFF kPa   598 578 618
Pressure with S/T OFF kgf/cm2   6.1 5.9 6.3
Basic   *
Oil temperature degC   50 48 52
Remarks
OFF
 
Stop lever angle_02
Pump speed r/min   1300 1300 1300
Pressure with S/T ON kPa   569 520 618
Pressure with S/T ON kgf/cm2   5.8 5.3 6.3
Oil temperature degC   50 48 52
Stop lever angle_03
Pump speed r/min   1500 1500 1500
Pressure with S/T OFF kPa   569 540 598
Pressure with S/T OFF kgf/cm2   5.8 5.5 6.1
Oil temperature degC   50 48 52
Stop lever angle_04
Pump speed r/min   1600 1600 1600
Pressure with S/T ON kPa   667 628 706
Pressure with S/T ON kgf/cm2   6.8 6.4 7.2
Pressure with S/T OFF kPa   598 578 618
Pressure with S/T OFF kgf/cm2   6.1 5.9 6.3
Basic   *
Oil temperature degC   50 48 52
Remarks
OFF
 
Stop lever angle_05
Pump speed r/min   1900 1900 1900
Pressure with S/T OFF kPa   696 667 725
Pressure with S/T OFF kgf/cm2   7.1 6.8 7.4
Oil temperature degC   50 48 52
Stop lever angle_06
Pump speed r/min   2200 2200 2200
Pressure with S/T OFF kPa   824 765 883
Pressure with S/T OFF kgf/cm2   8.4 7.8 9
Oil temperature degC   52 50 54
0000001101
Pump speed r/min   1600 1600 1600
Timer stroke with S/T ON mm   4.1 3.7 4.5
Timer stroke with S/T OFF mm   2.5 2.3 2.7
Basic   *
Oil temperature degC   50 48 52
Remarks
OFF
 
_02
Pump speed r/min   1300 1300 1300
Timer stroke with S/T ON mm   1.7 1.2 2.2
Oil temperature degC   50 48 52
_03
Pump speed r/min   1600 1600 1600
Timer stroke with S/T ON mm   4.1 3.6 4.6
Timer stroke with S/T OFF mm   2.5 2.3 2.7
Basic   *
Oil temperature degC   50 48 52
Remarks
OFF
 
_04
Pump speed r/min   1800 1800 1800
Timer stroke with S/T OFF mm   4.1 3.7 4.5
Oil temperature degC   50 48 52
_05
Pump speed r/min   2200 2200 2200
Timer stroke with S/T OFF mm   4.8 4.5 5.2
Oil temperature degC   52 50 54
0000001201
Max. applied voltage V   8 8 8
Test voltage V   13 12 14
Timing setting
K dimension mm   3.6 3.5 3.7
KF dimension mm   7.7 7.6 7.8
MS dimension mm   0.8 0.7 0.9
Pre-stroke mm   0.2 0.18 0.22
Control lever angle alpha deg.   18 14 22
Control lever angle beta deg.   37 32 42

Test data Ex:

0000001801 POTENTIOMETER ADJUSTMENT

Test data 104746-5450
Adjusting method (applied voltage Vi, dummy bolt method) 1. Hold the dummy bolt against the control lever at position N = N1 and Q = Q1 and fix using the lock nut. 2. At potentiometer adjustment, with the control lever contacting the dummy bolt, adjust the potentiometer so that the output voltage is V1. 3. After completing adjustment remove the dummy bolt. Confirm that the potentiometer output voltage is as specified above at the control lever idle position and full position. N:Pump speed Q:Injection quantity V:Output voltage A:Adjusting point B:Checking point I:Idle F:Full speed (C) Corresponding to dummy bolt 146526-3300 (D) Corresponding to nut 013020-6040 (E) Dummy bolt installation bracket
----------
N1=1420r/min Q1=26.2+-1.0mm3/st V1=4.33+-0.03V Vi=10V
----------
N1=1420r/min Q1=26.2+-1.0mm3/st V1=4.33+-0.03V V2=(1.53+-0.61V) V3=7.70+-0.72V

0000001901 V-FICD ADJUSTMENT

Test data 104746-5450
Adjustment of the V-FICD 1. Mount the V-FICD after the completion of potentiometer adjustment. 2. Confirm that the clearance between the control lever (B) and the actuator rod (A) is at least L2. 3. Insert the L1 shim between the control lever (D) and the idle set screw (C). 4. Adjust the stroke adjusting screw (E) so that the actuator moves through its full stroke, then fix using nut (F). Note When adjustment is not possible using the stroke adjusting screw (E), move the actuator rod position using (G), (H) and (I). Then, readjust the stroke using (E) and (F). 5. Apply negative pressure P1 to the actuator and confirm the full stroke. 6. After releasing negative pressure, re-confirm that the clearance between (A) and (B) is at least L2.
----------
L1=0.7+-0.1mm L2=1.0mm P1=-53.3kPa(-400mmHg)
----------
L1=0.7+-0.1mm L2=1.0++mm T1=1.4~2.0Nm(0.14~0.20kgfm) T2=3.4~4.9Nm(0.35~0.50kgfm)




Have questions with 104746-5450?





Group cross 104746-5450 ZEXEL

Isuzu 

104746-5450  

104746-5451 
 
8973503950 
INJECTION-PUMP ASSEMBLY
4JA1-L
9 460 614 166 
8973503951 
INJECTION-PUMP ASSEMBLY
4JA1-L
9 460 614 886 
8973503952 
INJECTION-PUMP ASSEMBLY
4JA1-L
9 460 614 901 
8973503953 
INJECTION-PUMP ASSEMBLY
4JA1-L
F 01G 09W 0BX 